FEATURES

• Multi-level PIR signal processing

*

• Digital Microwave signal processing
• DRO microwave technology for low current and reliable

operation

• MOV transient / static protection
• High RF immunity with SMD construction
• Exceptional white light immunity
• Microprocessor low voltage protection
• Optional tamper switch
• Optional Form ‘C’ alarm contacts

SPECIFICATIONS

ELECTRICAL

Operating  Voltage ................................................. 9.5 to 14.5 V

DC

Ripple Tolerance ................................................. 3 V

P-P

 at 12 V

DC

Stand-by Current ................................................ 30 mA at 12 V

DC

Alarm  Current ..................................................... 30 mA at 12 V

DC

Alarm Contacts ............................................. Form ‘A’ (standard)

Form ‘C’ (optional)

Tamper Contact .............................................................. Optional
Contact  Ratings ............................................... 100 mA at 24 V

DC

Alarm Contact Series Resistance ............................. 10

W

 0.25W

OPERATION

Coverage (max. length x max. width) ....... 30' × 40' (9m × 12m)
Alarm Duration ............................................................ 2 seconds
Walk Speed ......................... 0.5 ft/s to 10 ft/s (0.15m/s to 3.0m/s)
Nominal Mounting Height .......................................... 7.5' (2.3m)
Jumper .............................................................. Alarm LED on/off

IMMUNITY

RF Immunity ...................... 30 V/m over range 0.01 to 1200 MHz
Transients  at  Terminals ................................. 2.4 kV at 1.2 joules
Static Discharge Immunity .................................................. 10 kV
White Light ......................................... 20 000 Lux at the detector
Operating Temperature ..................... 32° to 122° F (0° to 50° C)
Humidity ................................ 5% to 95% RH non-condensing

**

DESCRIPTION

The Force 2 210 is a Short Range Dual Detector employing both
Microwave (MW) and Passive Infrared (PIR) motion sensors.  The
sensors are combined through a microprocessor to provide
“intelligent” motion detection designed to eliminate “single
detector” false alarms.

Significant new technical features such as Multi-Level PIR signal
processing, a high reliability DRO microwave sensor and digital
MW signal analysis combine for a new level of detection sensitivity,
stability and false alarm immunity.

The PIR and MW systems are each designed as independent, high
quality motion detectors.  When combined, the result is a detector
with unmatched performance.

The detector indicates an alarm when both sensors detect motion
within 10 seconds of each other.  The first sensor, either the PIR
or MW, which detects motion will start the 10 second confirmation
period during which the other sensor must also detect motion.  If
the first sensor’s detection is not confirmed within 10 seconds, the
unit disregards the alarm.

PIR / MW BEAM PATTERNS

PIR/MICROWAVE MOTION DETECTOR

F2-210 SERIES

INSTALLATION

INSTRUCTIONS

LOCATING THE DETECTOR

Mount the detector in a dry indoor location which will allow the
intruder to walk perpendicular to the beam, and allows the beam
pattern to adequately cover the area being protected.  Survey the
mounting location and the area being protected for the following
potential problems.

MOUNTING HEIGHT

The FORCE 2 is designed to provide optimum coverage when
mounted between 2.1m (7') to 2.4m (8’) from the floor.  If the unit
is mounted above 2.4m (8’), the PIR will have a slightly longer
range, but the “dead” zone directly below the unit will be increased.
If the unit is mounted below 2.1m (7’) the PIR section will have a
shorter range and the “dead” zone directly below the detector will
be decreased.

REFLECTIVE / METALLIC SURFACES

Do not aim the detector at reflective surfaces or metallic surfaces
that could vibrate. Reflective surfaces could distort the PIR coverage
pattern; vibrating metallic surfaces or rotating fans could be seen
as motion by the MW sensor. Metallic surfaces close to the unit may
reduce MW sensitivity.

AIR FLOW

The FORCE 2 is protected against air flow and airborne
contamination.  However, do not locate the detector where it will
be subject to direct high air flow such as fans, hot air vents or open
windows.

CONTAMINATION

Do not locate the detector near a source of oil or water vapour,
such as a steaming kettle or cooking area in a kitchen.

SUNSHINE

The FORCE 2 is resistant to white light but direct sunlight is a high
energy source.  Do not locate the detector where it will receive
direct sunlight, particularly in the morning or evening when the sun
is low and may shine in through a window.

TEMPERATURE CHANGES

Do not aim the detector at objects that change temperature rapidly,
such as heaters or ovens.

OBSTRUCTIONS

Do not limit the desired area of protection with large objects such
as plants or filing cabinets.

PETS

Do not aim the detector where pets may trigger either the Microwave
or PIR motion sensors.  If both sensors are tripped, an alarm will
result.

DISASSEMBLING THE DETECTOR

To open the detector, pull on the front of the detector while pressing
on the release at the bottom of the detector with a small screwdriver.

To remove the circuit board and sensor assembly from the detector
case, press gently on the top of the MW detector until the circuit
board unlocks and slides towards the bottom of the detector.

To replace the circuit board and sensor assembly, place the
circuit board assembly into the detector’s back so that the white
plastic frame fits into the two slots in the detector’s back.  Press
gently on the bottom of the MW detector assembly to slide the
circuit board towards the top of the detector.  The circuit board
assembly will snap firmly into place.

NOTE:  To avoid damage to the detector, do not press against
any of the components on the circuit board when removing and
replacing the board.

With the circuit board removed, use a small screwdriver to punch
out the wiring and mounting knockouts located in the detector’s
back.  Feed the wiring through the wiring knockout and secure the
detector to the wall.

J1

DM-C AND DM-W DETECTOR MOUNTING BRACKETS

*

Patented.

**

UL only verified up to 85% RH non-condensing.