Guidelines for Locating Smoke Detectors

Research has shown that all hostile fires in homes generate smoke to a greater or lesser extent.
Experiments with typical fires in homes indicate that detectable quantities of smoke precede
detectable levels of heat in most cases. For these reasons, smoke alarms should be installed out-
side of each sleeping area and on each storey of the home.
The following information is for general guidance only and it is recommended that local fire
codes and regulations be consulted when locating and installing smoke alarms.
It is recommended that additional smoke alarms beyond those required for minimum protec-
tion be installed. Additional areas that should be protected include: the basement; bedrooms,
especially where smokers sleep; dining rooms; furnace and utility rooms; and any hallways not
protected by the required units.
On smooth ceilings, detectors may be spaced 9.1m (30 feet) apart as a guide. Other spacing
may be required depending on ceiling height, air movement, the presence of joists, uninsulated
ceilings, etc. Consult National Fire Alarm Code NFPA 72, CAN/ULC-S553-M86 or other appro-
priate national standards for installation recommendations. 
• Do not locate smoke detectors at the top of peaked or gabled ceilings; the dead air space in 

these locations may prevent the unit from detecting smoke.

• Avoid areas with turbulent air flow, such as near doors, fans or windows. Rapid air movement 

around the detector may prevent smoke from entering the unit.

• Do not locate detectors in areas of high humidity.
• Do not locate detectors in areas where the temperature rises above 38

o

C

 

(100

o

F) or falls 

below 5

o

C (41

o

F).

• Smoke detectors should always be installed in accordance with NFPA 72, the National Fire 

Alarm Code. Smoke detectors should always be located in accordance with:

Smoke detectors shall be installed outside of each separate sleeping area in the immediate vi-

cinity of the bedrooms and on each additional storey of the family living unit, including base-
ments and excluding crawl spaces and unfinished attics. In new construction, a smoke detector
also shall be installed in each sleeping room’.

Split level arrangement: Smoke detectors are re-

quired where shown. Smoke detectors are optional where a door is not provided between liv-
ing room and recreation room’.

Figure 3a

Содержание PowerSeries SCW9047-433

Страница 1: ...mation on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read User Manual Self Contained Wi...

Страница 2: ...ngs GA 30122 Additional Information Connection to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for inf...

Страница 3: ...emote Arming and Disarming 4 Emergency Keys 4 When Alarm Sounds 4 Intrusion Burglar Alarm Continuous Siren 4 Fire Alarm Pulsed Siren 4 Time Date Programming 4 Bypassing Zones 4 Trouble Conditions 6 Al...

Страница 4: ...lay Test 11 Walk Test 11 Allowing Computer Access To Your System 11 Guidelines for Locating Smoke Detectors 12 Household Fire Safety Audit 13 Fire Escape Planning 13 This publications covers the follo...

Страница 5: ...If you initiate an alarm by mistake immediately call the central station to prevent an unnecessary response NOTE The monitoring function must be enabled by the installer before it becomes functional N...

Страница 6: ...anguages 3 Press to select your desired language Arming Disarming the System Stay Arming Stay arming will bypass the interior protection i e motion sensors and arm the perimeter of the sys tem i e doo...

Страница 7: ...remain on and the key pad will stop sounding Quick Exit If the system is armed and you need to exit use the Quick Exit function to avoid disarming and rearming the system Press and hold the Quick Exit...

Страница 8: ...ser can cancel by entering his access code an alarm that has been previously transmitted A cancel signal will be transmitted to the Central Station and the alarm system will also annunciate that the c...

Страница 9: ...last set of bypassed zones 1 Press then your access code if necessary 2 Press 3 To exit bypassing mode and return to the Ready state press Bypass Group A Bypass Group is a selection of zones programm...

Страница 10: ...ss code When programming is complete enter another 2 digit code to program or press to exit The access codes have programmable attributes which allow zone bypassing duress supervisor or one time use a...

Страница 11: ...the attributes of the code used to enter whether it is a new code or an existing code being programmed 2 System Master Code 40 has Attribute 3 ON by default NOTE These attributes are not changeable In...

Страница 12: ...uture Use 8 User Walk Test Allows the user to enter the Walk Test mode See Walk Test on page 11 Changing Brightness Contrast When this option is selected the keypad will allow you to scroll through 4...

Страница 13: ...____ Installer Information Company ___________________ Telephone __________________ If you suspect a false alarm signal has been sent to the central monitoring station call the station to avoid an unn...

Страница 14: ...10 Sensor Zone Information Sensor Protected Area Sensor Type Sensor Protected Area Sensor Type 01 18 02 19 03 20 04 21 05 22 06 23 07 24 08 25 09 26 10 27 11 28 12 29 13 30 14 31 15 32 16 33 17 34...

Страница 15: ...The system will also automatically terminate the Walk Test on completion it will annunciate with an audi ble warning 5 beeps every 10 seconds beginning five minutes before the termination of the test...

Страница 16: ...Consult National Fire Alarm Code NFPA 72 CAN ULC S553 M86 or other appro priate national standards for installation recommendations Do not locate smoke detectors at the top of peaked or gabled ceilin...

Страница 17: ...indows are easily opened Ensure that they are not painted shut and that their locking mechanisms operate smoothly If opening or using the exit is too difficult for children the elderly or handicapped...

Страница 18: ...14...

Страница 19: ...NOTES...

Страница 20: ...a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detectors such as when the fire is in a chimney...

Отзывы: