DSC PowerSeries PC5108FLR Скачать руководство пользователя страница 1

 

8 Zone Expander Module

This Installation sheet shall be used in conjunction with the Installation Manual of the

DSC equipment to which PC5108FLR is connected or powered from  (e.g. alarm controller,

power supply, etc.). The PC5108FLR module can be used to extend up to 8 hardwired fast

loop response zones on the compatible DSC Alarm Controllers, models PC5020, PC1864,

PC1832 and PC1616.  The fast loop response will be approximately 25ms.

General

PC5108FLR may be installed in the same metallic cabinet as the alarm controller/power

supply (model Power UC1, PC5003C) or in a separate enclosure (PC4003C). Internal and/

or external wiring for the PC5108FLR shall be routed, supported, clamped or secured in a

manner that reduces the likelihood of (a) excessive strain on wire and terminal connections

(b) loosening of terminal connections and (c) damage of conductor insulation.

Specifications

•Temperature range: -10°C to + 55°C

•Relative Humidity: 93% non condensing

•Input rating: 12V

DC

/135mA (provided by the alarm controller or separate power supply)

•Board current draw: 35mA (set and unset state)

•Board dimensions: 45mm x 92mm

•VAUX output ratings: 12V

DC

, -15%/ +10% when Input voltage is between 85% 

to110% of rated value and output current is between 0mA- 100mA max.

•Ressetable fuse (PTC) used on circuit board instead of replaceable fuses

Terminal Descriptions

TAM - 

Used to tamper the cabinet in which the PC5108FLR is mounted. Connect a nor-

mally closed (NC) switch across TAM and BLK. If the tamper is not being used connect a

piece of wire across TAM and BLK to remove the trouble condition. 

There is a built-in tamper switch on the expander module located in the top left corner of

the circuit board. If the cabinet in which the PC5108FLR is mounted has the hardware

required to depress this tamper switch, do not connect anything to the TAM terminal.

VAUX

 - Used to provide power for devices. Maximum current draw is not to exceed 100

mA. Connect the positive lead of powered devices to VAUX and the negative to BLK or any

COM terminal.

KEYBUS 

- The 4 wire KEYBUS connection is used by the panel to communicate with the

module. Connect the RED, BLK, YEL and GRN terminals to the KEYBUS terminals on the

PC1616, PC1832, PC1864 & PC5020 main control.

Z1 to Z8

 - Wire the zones according to the description found in the control panel Instal-

lation Manual.

Enclosures

The PC5108FLR can be installed in the metal enclosures listed below. Tamper protection

switches can be installed on all enclosures, including door opening protection and/or

removal from the mounting position. Doors can be secured using screws or keylock.

•Model PC5003C (removable door) made of 22Ga steel, painted, dimensions:  

248mm(L) x 298mm(W) x 76mm(H), weight: 1500g.

•Model PC5003C (hinged door) made of 1.2mm thick steel, painted, dimensions: 

248mm(L) x 298mm(W) x 76mm(H), weight: 2500g

•Model Power UC1 made of 18Ga steel, painted, dimensions: 315mm(L) x 319mm(W) x 

100mm(H), weight: 3150g.

•Model PC4003C made of 18Ga steel, painted, dimensions: 230mm(L) x 180mm(W) x 

75mm(D), weight 1050g.

Jumper Settings

The PC5108FLR module can be used

to add up to 8 additional hardwired

fast loop response zones to the

PC1616, PC1832, PC1864 or

PC5020 control panel (see Installa-

tion Manual for complete installation

instructions).

Jumpers

The PC5108FLR will operate in a sin-

gle group of eight zones. Refer to the

following jumper settings:

To Add Hardwired Zones to a Control Panel

1. Connect module to the Keybus (with the panel powered down).

2. Set the jumpers on the module.

3. Power up the system.

4. Enter section [902] and wait 1 minute.

5. Enter section [903] to verify that the module is supervised.

6. Define the zones in sections [002]-[004] for PC1616, PC1832, PC1864 or PC5020.

7. Add the zones to the appropriate partition in sections [202]-[265].

LIMITED WARRANTY

Digital Security Controls warrants that for a period of twelve months from the date of pur-
chase, the product shall be free of defects in materials and workmanship under normal use and
that in fulfilment of any breach of such warranty, Digital Security Controls shall, at its option,
repair or replace the defective equipment upon return of the equipment to its factory. This
warranty applies only to defects in parts and workmanship and not to damage incurred in
shipping or handling, or damage due to causes beyond the control of Digital Security Controls
such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out
of abuse, alteration or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any
and all other warranties, whether expressed or implied and of all other obligations or liabilities
on the part of  Digital Security Controls. This warranty contains the entire warranty. Digital
Security Controls neither assumes responsibility for, nor authorizes any other person purport-
ing to act on its behalf to modify or to change this warranty, nor to assume for it any other
warranty or liability concerning this product. In no event shall Digital Security Controls be
liable for any direct or indirect or consequential damages, loss of anticipated profits, loss of
time or any other losses incurred by the buyer in connection with the purchase, installation or
operation or failure of this product.

Warning: Digital Security Controls recommends that the entire system be completely
tested on a regular basis. However, despite frequent testing, and due to, but not limited to,
criminal tampering or electrical disruption, it is possible for this product to fail to per-
form as expected.

FCC COMPLIANCE STATEMENT
CAUTION: Changes or modifications not expressly approved by Digital Security
Controls could void your authority to use this equipment.

This equipment generates and uses radio frequency energy and if not installed and used
properly, in strict accordance with the manufacturer’s instructions, may cause interference
to radio and television reception. It has been type tested and found to comply with the limits
for Class B device in accordance with the specifications in Subpart “B” of Part 15 of FCC
Rules, which are designed to provide reasonable protection against such interference in any
residential installation. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause interference to television or radio recep-
tion, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Re-orient the receiving antenna
• Relocate the alarm control with respect to the receiver
• Move the alarm control away from the receiver
• Connect the alarm control into a different outlet so that alarm control and receiver are on
different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician
for additional suggestions. The user may find the following booklet prepared by the FCC
useful: “How to Identify and Resolve Radio/Television Interference Problems”. This book-
let is available from the U.S. Government Printing Office, Washington D.C. 20402, Stock #
004-000-00345-4.

PC5108FLR v2.0 Installation Instructions

PC5108

SW1

J6

J4

ON

OFF

OFF

ON

ON

OFF

J5

J1

J2

J3

VAUX

TAM

Z1 COM Z2

Z3 COM Z4

Z5 COM Z6

Z7 COM Z8

Z8

RED BLK YEL GRN

BLK

BLK

RED

RED

GRN

GRN

YEL

YEL

VAUX

12V

DC, LIMITED

AT 100mA

TO DEVICES

REQUIRING POWER

TO COM

KEYBUS TO
ADDITIONAL
EXPANSION
MODULES

KEYBUS TO

PRECEDING

EXPANSION

MODULE OR

CONTROL

PANEL

Expander Zones

Jumpers

Zones Assigned

Group A (Zones1-8) J1 J2 J3

Group B (not used)

ON ON ON Zones Disabled

OFF ON ON Zones 9-16 

ON OFF ON Zones 17-24

OFF OFF ON Zones 25-32 

ON ON OFF Zones 33-40 

OFF ON OFF Zones 41-48 

ON OFF OFF Zones 49-56 

OFF OFF OFF Zones 57-64 

©2008 Digital Security Controls   Toronto,  Canada 

 

•  

www.dsc.com

Tech. Support: 1-800-387-3630  (Canada & U.S.), 905-760-3036

Printed in Canada

2 9 0 0 7 4 9 2 R0 0 1

Отзывы: