DSC Power632 PC1555 Скачать руководство пользователя страница 4

Содержание Power632 PC1555

Страница 1: ...tations regarding product use and function and information on the liniitations as to liability of the inanufacturer The entire inanual should be carefully read Instruction Manual IbWer632 PC 1555 PC 1...

Страница 2: ...re Disclaimer of Warranties To obtain service under this warranty please return the item s in This warranty contains the entire warranty and shall be in lieu of question to the point of purchase All a...

Страница 3: ...ponse NOTE Your installer must enable the monitoring feature before it will work General System Operation Your security system is made up of a DSC control panel one or more keypads and various sensors...

Страница 4: ...l in a safe place Access Codes Your Master Code is Additional Access Codes 01 09 17 25 02 10 18 26 03 11 19 27 04 12 20 28 05 13 21 29 06 14 22 30 07 15 23 31 08 16 __ 24 32 Zone Information There are...

Страница 5: ...2 23 24 25 26 27 28 29 30 31 32 F FIRE A AUXILIARY P PANIC The Exit Delay Time is seconds The Entry Delay Time is seconds For Service Central Station Information Account Telephone Installer Informatio...

Страница 6: ...elay period indicated by keypad beeps for you to exit the premises without causing an alarm At the end of the exit delay period all keypad lights except the Armed light will turn OFF and the system wi...

Страница 7: ...en you enter your security code to arm the system or press the Stay button on the keypad and do not exit the premises through a designated Exit Entry door the system will arm in the Stay mode automati...

Страница 8: ...rm Memory Display mode Disarming from an LCD Keypad Upon entering through a designated Exit Entry door the keypad will beep and the entry delay will commence reminding you to disarm the system The key...

Страница 9: ...of the function keys talk to your alarm installer Programming Security Codes Programming codes from an LED or Fixed Message LCD5501Z keypad The Master Code To program the Master Code enter 5 current M...

Страница 10: ...s busy bypassed see Zone Bypassing on page 11 NOTE If you have a PC1555RKZ keypad the System light acts as a Trouble Memory Programming and Fire Light Message Bypass indicator Unlike the other keypads...

Страница 11: ...conds to send a PANIC LCD display to view alarms or troubles to arm and disarm transmission the system and to bypass zones IMPORTANT NOTE All Keypads The Fire To exit a function and return to the Read...

Страница 12: ...e the arrow keys to scroll to the following message F re__ r r Press Display will read Rc f odes Er t er riaster Enter the Master Code Display will read Fi Code 1 1 t Edit Use the scroll keys to find...

Страница 13: ...ake enter that zone number again the zone light will turn OFF indicating that the zone is not bypassed Press to return to the Ready state To bypass zones from an LCD keypad To bypass a zone the system...

Страница 14: ...ors 1 to 32 Press 7 again 2 Handheld keypads with low batteries LED Fixed Message LCD keypad zone indicators 1 to 4 Press 7 again 3 Wireless keys with low batteries LED keypad zone indicators 1 to 8 T...

Страница 15: ...the zone light turn ON when the zone is activated The zone light will turn OFF when the system restores to normal i e door or window closed From an LCD keypad the following message will be displayed w...

Страница 16: ...pad Press to enter the function list Scroll to find F F e__ F r Press to select the output control The display will read iiut pi t Cor t r o1 Select it p ut Use the arrow keys to find the following me...

Страница 17: ...neighbour s house Once everyone is out of the building call the Fire Department A good plan emphasizes quick escape Do not investigate or attempt to fight the fire and do not gather belongings or pets...

Страница 18: ...ed below for USOC Jack RJ 31 X information on obtaining service or repairs The telephone company may ask TELEPHONE CONNECTION REQUIREMENTS Except for the telephone that you disconnect this equipment f...

Страница 19: ...rning Devices cient coverage disconnect a warning device or interfere with or pre vent the proper operation of the system Warning devices such as sirens bells horns or strobes may not warn Power Failu...

Страница 20: ...2002 Digital Security Controls Ltd Direct all comments and suggestions Toronto Canada www dsc com concerning DSC publications to Printed in Canada 29004474 R003 pubs dscltd com...

Отзывы: