DSC Power432 PC585 Скачать руководство пользователя страница 10

8

PC5508Z LED Keypad

Memory Light 

/  Message

Upon disarming, if an alarm has occurred while the
system was armed, the Memory light will turn ON (see
“Disarming the System” on page 6).

Bypass Light / Message

If the Bypass light is ON, one or more zones are
bypassed (see “Zone Bypassing”

  on page 11).

Fire Light / Message

If the Fire light is ON, a fire alarm has occurred (see
“Fire Alarm Operation” on page 14).

Program Light / Message

The Program light will flash when you are
programming access codes, or performing other
programming functions. If someone is programming
at another keypad, the Program light will turn ON to
indicate that the system is bus

y.

The 

PC5516Z 

and 

PC5532Z 

Keypads

are available for applications with more
than 8 zones. The functions explained in
this manual are the same for all three LED
keypad types.

PC1555RKZ LED Keypad

System Light (PC1555RKZOnly):

If the System light is ON, one or more of these conditions
could be present on the system:

System Busy

System Troubles (see 'Viewing Trouble Conditions' on page 11).

Alarm Memory (see 'Disarming the System' on page 6).

Zone Bypassing (see 'Zone Bypassing'  on page 11).

Programming   The System light will flash when you are
programming access codes, or performing other
programming functions. If someone is programming at
another keypad, the System light will turn ON to indicate that
the system is busy.

NOTE: If you have a PC1555RKZ keypad, the System
light acts as a Trouble, Memory, Programming and
Bypass indicator. Unlike the other keypads, these
conditions will only be represented by the System light.
Please keep this in mind when reading other functions in
this manual.

Emergency Keys (PC1555RKZ)

Press the [F]* key for 2 seconds to send a FIRE
transmission.

Press the [A]* key for 2 seconds to send an AUXILIARY
transmission.

Press the [P]* key for 2 seconds to send a PANIC
transmission.

PC5516Z LED Keypad

PC5532Z LED Keypad

9

The 

Liquid Crystal Display

 (LCD) displays prompts and

system information on two 16 character lines.

If  “< >” appears, more information can be accessed by
using the arrow (< >) keys. Press 

[<]

 to see the previous

function or item of information.  Press 

[>]

 to advance the

display to next function or item of information.

Press the keys on the number pad as prompted by the
LCD display to view alarms or troubles, to arm and disarm
the system and to bypass zones.

To exit a function and return to the Ready state,  press [#].  To
select a function press [

].

Display Lights (All Keypads)

Ready Light

If the Ready light is ON, the system is ready for arming.
The system cannot be armed unless the Ready light is
ON (see 'Arming the System' on page 4).

Armed Light

If the Armed light is ON, the system has been armed
successfully.

Trouble or System Light

If the Trouble light is ON, see “Viewing Trouble
Conditions” on page 11.

LCD5500Z Keypad

Emergency Keys

Press both  * keys for 2 seconds to send a FIRE
transmission.

Press both 

* keys for 2 seconds to send an

AUXILIARY transmission.

Press both 

* keys for 2 seconds to send a PANIC

transmission.

* IMPORTANT NOTE (All Keypads):  The Fire,
Auxiliary and Panic keys will NOT function unless
programmed by the installer. If these keys are in
service and the installer has enabled audible
feedback, holding down the key for two seconds
will cause the keypad sounder to beep indicating
that the input has been accepted and transmission

is underway. The [A] and 

 keys are programmed

to be used for non-medical emergencies only in
the United States, as per UL requirements.

IMPORTANT NOTE: Test system weekly
and have any system trouble conditions
corrected by your alarm installer.

LCD5501Z Fixed Message Keypad

Содержание Power432 PC585

Страница 1: ...omments and suggestions concerning DSC publications to pubs dscltd com Instruction Manual W A R N I N G This manual contains information on limitations regarding product use and function and informati...

Страница 2: ...as possible the system may fail to function as intended due to the failure of a component Inadequate Testing Most problems that would prevent an alarm system from operating as in tended can be found b...

Страница 3: ...ions to maintain uninterrupted service Equipment Maintenance Facility Equipment Maintenance Facility Equipment Maintenance Facility Equipment Maintenance Facility Equipment Maintenance Facility If tro...

Страница 4: ...plan 2 Study the possible escape routes from each location within the house Since many fires occur at night special attention should be given to the escape routes from sleeping quarters 3 Escape from...

Страница 5: ...stored safely in closed containers in a well ventilated cool area Cleaning with flammable liquids should be avoided 3 Are fire hazardous materials matches well out of reach of children 4 Are furnaces...

Страница 6: ...xpires Exit through the door indicated by your installer as the Exit Entry door This message will be displayed once the exit delay expires and the system is fully armed If this message appears be awar...

Страница 7: ...zones or if one of the perimeter zones is violated the alarm sequence will begin To arm in the Away mode enter your access code and exit the premises through a designated Exit Entry door The system wi...

Страница 8: ...d Any alarms showing are alarms that occurred only during the last armed period Entry Active Enter Your Code Enter Code to Arm System Secure System Before Arming Enter Code to Arm System View Memory Z...

Страница 9: ...your system has been installed with fire detectors and the alarm sounds in a pulsing mode follow your emergency evacuation plan immediately see Fire Escape Planning on page 15 Intrusion Alarm If an i...

Страница 10: ...d a FIRE transmission Press the A key for 2 seconds to send an AUXILIARY transmission Press the P key for 2 seconds to send a PANIC transmission PC5516Z LED Keypad PC5532Z LED Keypad 9 The Liquid Crys...