Operation

The PGx945 Series is a supervised, 2-way wireless PowerG

magnetic contact device. The device includes a built-in reed switch

and a separate N.O., N.C. or E.O.L programmable auxiliary hard-

wired input for use with other hardwired sensors (use only UL/

ULC fire/burglary listed sensors).

The reed switch and the auxiliary input behave as separate

transmitters, although they trigger the same RF transmitter.

Removing the cover activates the tamper switch. If configured,

LED lights only when reporting alarm or tamper events. Built-in

link quality indicators reduce installation time by eliminating the

need for the installer to physically approach the control panel.

Low-Battery Detection

The PGx945 includes low-battery condition detection. When this

condition is detected a trouble message is transmitted to the

compatible receiver/control panel. This will provide visual

identification of the unit that requires a battery change. For UL

commercial burglary installations replace battery yearly.

Device Setup

WARNING!

 To comply with FCC and IC RF exposure

compliance requirements, the magnet contact device should be

located at a distance of at least 20 cm from all persons during

normal operation. The antennas used for this product must not be

co-located or operated in  conjunction with any other antenna or

transmitter.

CAUTION!

This product uses Lithium Batteries. Improper handling of lithium

batteries may result in HEAT GENERATION, EXPLOSION or

FIRE, which may lead to personal injuries. 

WARNING!

 

Danger of explosion if batteries are installed incorrectly. replace

only with the same or equivalent type recommended by the

manufacturer. Dispose of used batteries according to the

manufacturer's instructions.

Keep away from small children: if swallowed promptly see a

doctor. 

Do not try to recharge these batteries.

Note:

 Battery replacement should be done by installer.

Note: 

To ensure the continued operation of all wireless devices

after performing a system default, a global upload of all wireless

programming via DLS is recommended before defaulting the

system. After completing the system default, download the

wireless programming. 

Legend

A. Flexible Retainer

B. Break-away base segment (for back tamper)

C. PCB edge supports

D. Mounting holes

E.

Wiring inlet

F.

LED

G.

Terminal block for sensor

H. Enroll button

I.

Tamper switch

J.

Reed switch on underside of PC Board (in unit)

K. Symbol on side of the case indi-

cates location of reed switch

L.

Magnet

M. 1/4" space maximum (6mm)

N. 47 k

 resistor

O. N.C. switch

P.

N.O. switch

Install the battery

1.

Insert a flat-edged screwdriver 

into the slot and push upward to 

remove cover.

2.

Remove the screw and separate 

the cover from the base.

3.

Observe polarity and install 

battery.

4.

Connect the sensor wire to the 

terminal block.

Note: 

When manually programming

wireless devices, if a device has been

powered up for more than 48 hours it

cannot be enrolled into the system until

the device has been tampered and

restored. When programming the panel

using the Quick Enroll procedure follow

the steps detailed in Enroll the Device into

the System.

Note: 

After restoring a low battery trouble the system may take

up to 5 minutes to clear the trouble.

Enroll the Device into the System

Refer to the PowerSeries Neo Host Installation Manual or iotega

Reference Manual for the enrollment procedure.

Placement Testing

Before permanently mounting any wireless device, temporarily

mount the device and perform a Placement test.

1.

Tamper the device by removing the cover.

2.

Replace the cover to restore the tamper.  The device now 

enters Placement test mode for 15 minutes. 

3.

Trip the device by opening the door or window and verify the 

red LED blinks, indicating detection.

4.

After 2 seconds the LED blinks 3 times.The following table 

indicates received signal strength.

IMPORTANT! 

Only GOOD or STRONG signal strengths are

acceptable. If you receive a POOR signal from the device, re-locate

it and re-test until a GOOD or STRONG signal is received. 

Note:

 For UL/ULC installations, only STRONG signal levels are

acceptable. After installation verify the product functionality in

conjunction with the compatible receivers HSM2HOST9,

HS2LCDRF(P)9, HS2ICNRF(P)9, PG9920, WS900-19, and

WS900-29.

Note:

 For detailed Placement instructions refer to the control panel

Reference Guide

Gap Separation

Mounting the Device

It is highly recommended to attach the transmitter to the top of the

door/window on the fixed frame and the magnet to the door or

window. Ensure that the magnet is located not more than 6 mm

(0.25 in.) from the transmitter’s marked side. 

Note:

 Once the cover is removed, a tamper message is transmitted

to the receiver. Subsequent removal of the battery prevents

transmission of tamper restore, leaving the receiver in permanent

alert. To avoid, press the tamper switch while removing the battery.

Attention!

The unit has an optional back tamper switch under the PCB. As

long as the PCB is seated firmly within the base, the switch lever

will be pressed against a special break-away base segment that is

loosely connected to the base. Be sure to fasten the break-away

segment to the wall. If the detector unit is forcibly removed from

the wall, this segment will break away from the base, causing the

tamper switch to open.

Note:

 For UL Residential Fire and Commercial Burglary

installations, the use of the back tamper is mandatory.

Note: 

Adhesive tape not to be used for EU Market.

Mounting with screws

Note:

 For UL Residential Fire and Commercial Burglary

installations, the use of the mounting screws is mandatory.

1.

With the cover removed, flex retainer and remove PCB. 

2.

Mark & drill 2 holes in mounting surface.

3.

Fasten base with 2 countersunk screws.

4.

Mount the magnet base with 2 supplied screws.

5.

Attach the magnet to the magnet base.

Mounting with adhesive tape

1.

Peel away the release liners from the two strips of double-

sided adhesive tape and attach to the device and magnet.

2.

Align the device with the magnet according to the location 

marks and fasten the device and magnet to the mounting sur-

face.

Auxiliary Input wiring

1.

Connect the auxiliary sensor contacts across the auxiliary 

input terminals.

2.

If the auxiliary input is defined as a Normally Closed (N.C.) 

type, series connected N.C. sensor contacts must be used 

exclusively. An E.O.L. resistor will not be required. 

3.

If the auxiliary input of the is defined as a Normally Open 

(N.O.) type, parallel connected N.O. sensor contacts must be 

used exclusively. An E.O.L. resistor will not be required.

4.

For E.O.L. supervision: Normally Closed (N.C.) sensor con-

tacts can be used. A 47 k

 E.O.L. resistor must be wired at 

the far end of the zone loop.

Note:

 For UL installations, the device connected to the initiating

circuit must be located in the same room as the transmitter.

The drawing below illustrates a N.O. and N.C. alarm circuit with

E.O.L. resistor.

Note:

 An alarm message is transmitted once the loop is opened or

short circuited.

Note:

 For UL/ULC installations connect only UL/ULC listed

device to the auxiliary wiring input. Only one device shall be

connected to the input of each RF transmitter.

UL985 short range RF transmitter application

Model PG9945 is also UL985 listed as a short range RF transmitter

for use in Residential fire applications in conjunction with UL

listed mechanical heat detectors. The transmitter shall be installed

using provided screws and the back tamper shall be enabled. The

heat detector shall be connected to the wired input of the RF

transmitter device in the same room and within 3 ft. The External

Input [001][03] shall be set to [Y] and the Zone EOL [002] shall be

set to [02] Normally Open. The Supervision [001][04] shall be

enabled [Y] and Reed switch[001][02] operation shall be disabled

[N]. When enrolling the device in the compatible receiver/control

panel combination set the zone definition to type [08] in order to

transmit a fire alarm when the external input is activated. An

example of compatible initiating devices that could be used in this

type of application is the System Sensor UL listed 5600 Series

Mechanical Heat Detectors (only models that have self restoring

rate of rise sensors). Refer to the compatible devices installation,

testing, and maintenance instructions. Test the self-restoring rate of

rise models using a hair dryer or heat gun. When testing the ROR

element, to prevent the activation of the fixed temperature element,

the heat source must not exceed the fixed temperature rating of the

detector. Detectors shall be installed as per NFPA72 and/or the

local authority having jurisdiction. 

Note: 

Ensure the RF transmitter is used in its intended

environmental conditions.

Configuration

The enter the wireless configuration section enter [804][3 digit

zone number]

Selections

Specifications

Frequency Band (MHz): 

CE Listed PG4945: 433MHz; CE/EN

listed PG8945: 868MHz; FCC/IC/UL/ULC listed PG9945: 912-

919MHz band 

Communication Protocol:

 PowerG

Alarm Input:

 One internal

Supervision:

 Signaling at 4 minute intervals

Tamper Alert:

 Reported when a tamper event occurs

Battery type:

 3 V Lithium CR-123A type battery GP

Battery Life Expectancy:

 8 years (for typical use)

Battery Supervision:

 Automatic transmission of battery condition

data as part of periodic status report and immediately upon low

battery condition detection

Temperature range:

 -10ºC to +55ºC (UL/ULC only verified the

range 0ºC-49ºC)

Relative Humidity:

 up to max. 93%RH, non-condensing

Dimensions (LxWxD):

 81 x 34 x 25 mm (3-3/16 x 1-1/4 x 1 in.)

Weight (including battery):

 53g (1.9 oz)

Auxiliary Input Cable Length:

 10m max, AWG22

Auxiliary Input EOL Resistor: 

47 K

Installed by service persons and for use in indoor non-hazardous

locations only.

Low Battery trouble level:

 2.2V

Compatible Receivers

This device can be used with DSC panels and receivers that use

PowerG technology.

UL/ULC Notes

The PG9945 has been listed by UL for commercial and residential

burglary and residential fire applications and by ULC for

commercial and residential burglary applications in accordance

with the requirements in the Standards UL 985 (resi fire

applications) and UL634 and ULC/ORDC634 for Door and

Window Contact. For UL/ULC installations use this device only in

conjunction with compatible DSC wireless receivers:

HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P)9, PG9920,

WS900-19, and WS900-29.

Europe: The PG8945 is certified by Telefication to the following standards: EN50131-2-6, EN50131-
1 GRADE 2, CLASS II, EN50131-6 Type C. Telefication BV has certified only the 868 MHz variant of
this product. According to EN 50131-1:2006 and A1:2009, this equipment can be applied in
installed systems up to and including Security Grade 2, Environmental Class II. UK: The PG8945 is
suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and environmental class

2. BS8243 The Power G peripheral devices have two- way communication functionality, providing additional benefits as
described in the technical brochure. This functionality has not been tested to comply with the respective technical
requirements and should therefore be considered outside the scope of the product’s certification.

SIMPLIFIED EU DECLARATION OF 

CONFORMITY

Hereby, Tyco Safety Products Canada Ltd declares that the radio equipment type is in compliance with Directive 2014/53/
EU. The full text of the EU declaration of conformity is available at the following internet address:
PG8945 - http://dsc.com/pdf/1401040
PG4945 - http://dsc.com/pdf/1401017

European single point of contact: Tyco Safety Products, Voltaweg 20, 6101 XK Echt, Netherlands.

FCC COMPLIANCE STATEMENT

WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void
the user’s authority to operate the equipment.
This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio and television reception.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such
interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by
one or more of the following measures:
– Re-orient or re-locate the receiving antenna.
– Increase the distance between the device and the receiver.
– Connect the device to an outlet on a circuit different from the one that supplies power to the receiver.
– Consult the dealer or an experienced radio/TV technician.
This equipment complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled environment.
This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). Operation is subject
to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference that may be received or that may cause undesired operation.
Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.
L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur
de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le
fonctionnement.

PG9945_PG8945_PG4945

Instructions d'installation du détecteur de 

contact magnétique sans fil bidirectionnel 

PowerG à entrée câblée

Fonctionnement

Le PGx945 Series est un dispositif à contact magnétique, sans fil,

bidirectionnel, supervisé PowerG. Le dispositif contient un

commutateur à lames intégré et une entrée câblée auxiliaire

programmable N.F., N.O ou E.D.L., à part à utiliser avec d'autres

détecteur câblés (utilisez exclusivement des détecteurs anti-

intrusion/anti-incendie homologués UL/ULC.).

Le commutateur à lames et l'entrée auxiliaire se comporte comme

des émetteurs distincts, même s'ils déclenchent un émetteur RF

identique. Le retrait du capot active le contact anti-sabotage. S'ils

sont configurés, les voyants lumineux s'allument uniquement en

cas de signalisation d'alarme ou d'événements de sabotage. Les

indicateurs de qualité de liaison intégrés réduisent les temps

d'installation en supprimant la nécessité de l'installateur d'être

physiquement à proximité de la centrale.

Détection de niveau faible de batterie

Le PGx945 possède une fonction de détection de niveau faible de

batterie. Quand cet état est détecté, un message de problème est

transmis à la centrale ou au récepteur compatible. Une signalisation

visuelle est ainsi assurée pour l'unité qui a besoin d'un

remplacement de la batterie. Pour les installations anti-intrusion

commerciales UL, remplacez la batterie tous les ans.

Réglage du dispositif

AVERTISSEMENT !

 Pour la compatibilité avec les exigences

d'exposition IC RF et FCC, le dispositif à contact magnétique doit

être placé à une distance d'au moins 20 cm des personnes pendant

le fonctionnement normal. Les antennes utilisées avec ce produit

ne doivent pas être placées ni utilisées en association avec une

autre antenne ou un autre émetteur.

ATTENTION !

Ce produit utilise des batteries au lithium. La manipulation

incorrecte des piles au lithium peut engendrer UNE

PRODUCTION DE CHALEUR, UNE EXPLOSION ou UN

INCENDIE, qui peuvent provoquer des blessures personnelles. 

AVERTISSEMENT !

 

Risque d'explosion si les piles sont mal installées. Remplacez

exclusivement par des piles identiques ou de type équivalent

comme recommandé par le fabricant. Éliminez les piles usagées

selon les instructions de son fabricant.

Éloignez les jeunes enfants : si elles sont avalées, consultez

rapidement un docteur. 

N'essayez pas de recharger ces piles.

Remarque :

 Le remplacement des batteries doit être réalisé par un

installateur.

Remarque :

 Pour garantir le fonctionnement continu de tous les

dispositifs sans fil après avoir réalisé une réinitialisation aux

valeurs par défaut, un téléchargement général de toute la

programmation sans fil par DLS est recommandé avant de

réinitialiser le système. Après avoir complété la réinitialisation aux

valeurs par défaut du système, téléchargez la programmation sans

fil.

Légende

A. Collier de retenue flexible

B. Segment de la base défonçable (pour le contact anti-sabotage 

arrière)

C. Supports en bordure de la carte du circuit imprimé

D. Trous de fixation

E.

Entrée à câbler

F.

Voyant

G.

Bornier du capteur

H. Bouton d'attribution

I.

Contact anti-sabotage

J.

Commutateur à lames sur le dessous du circuit imprimé (dans 

l'unité)

K. Un symbole sur le côté du boîtier indique l'emplacement du 

commutateur à lames

L.

Aimant

M. espace minimum de 6 mm (1/4")

N. Résistance de 47 k

O. Contact N.F.

P.

Contact N.O.

Installer la pile

1.

Insérez un tournevis plat dans la 

fente et poussez vers le haut pour 

retirer le couvercle.

2.

Retirez la vis et détachez le 

couvercle de la base.

3.

Respectez les polarités et installez 

la pile.

4.

Branchez les fils du détecteur au 
bornier.

Remarque :

 Quand vous programmez

manuellement les dispositifs sans fil, si un

dispositif a été alimenté pendant plus de 48

heures, il ne peut pas être attribué dans le

système tant que le dispositif n'a pas été

saboté et rétabli.

Remarque: 

Après la restauration d'un

défaut de batterie faible, le système peut

prendre jusqu'à 5 minutes pour que la

peine.

Attribuer le dispositif dans le système

Consultez les instructions d'installation PowerSeries Neo Host ou

le manuel de référence iotega pour plus informations sur

l'attribution.

Test de positionnement

Avant de fixer de façon permanente un dispositif sans fil

quelconque, montez-le temporairement et effectuez un test de

positionnement.

1.

Sabotez le dispositif en retirant le cache.

2.

Remontez le couvercle pour rétablir le contact anti-sabotage. 

Le dispositif passe en mode de test de positionnement pendant 

15 minutes. 

3.

Déclenchez le dispositif en ouvrant la porte ou la fenêtre et 

vérifiez que le voyant lumineux rouge clignote ce qui indique 

la détection.

4.

Après 2 secondes, le voyant clignote 3 fois. Le tableau suivant 

indique la force du signal reçu.

IMPORTANT ! 

Seules les forces de signal FORT ou BON sont

acceptables. Si vous recevez un signal FAIBLE du dispositif,

déplacez-le et testez-le à nouveau jusqu'à ce qu'un signal BON ou

FORT soit reçu. 

Remarque :

 Pour les installations UL/ULC, seul un signal FORT

est acceptable. Après installation, vérifiez les fonctionnalités de

l'appareil en association avec les récepteurs compatibles

HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P)9, PG9920,

WS900-19, et WS900-29.

Remarque :

 Pour des instructions détaillées sur le positionnement,

consultez le guide de référence de la centrale.

B

A

C

D

E

LED response

Signal Strength 

Green LED blinks

STRONG 

Orange LED blinks

GOOD 

Red LED blinks

POOR 

No blinks

No communication

Metallic (Ferrous) 
Materials

Nonmetallic/Metallic 
(nonferrous) Materials

Direction of 
Movement of 
the Magnet

Approach/
Make

Remove/
Break

Approach/
Make

Remove/
Break

Axis Y

10 mm ± 5 
mm

15 mm ± 5 
mm

14 mm ± 5 
mm

15 mm ± 5 
mm

Axis X

12 mm ± 5 
mm

15 mm ± 5 
mm

14 mm ± 5 
mm

20 mm ± 5 
mm

Axis Z

10 mm ± 5 
mm

10 mm ± 5 
mm

24 mm ± 5 
mm

25 mm ± 5 
mm

Recommended maximum gap separation for installation (on speci-
fied materials and axes of use) is 6mm (0.24”). 

}

J

L

K

M

Z

X

Y

[001][01] Alarm LED - 

Default [Y]

Enables the devices LED

to activate when an alarm

event occurs.

[001][02] Reed Switch - 

Default [Y]

Enables\disables the reed 
switch. 

Note: 

It shall be set 

to [N] for UL fire applica-
tions.

[001][03] External Input - 

Default [N]

Enables\disables the exter-
nal input. 

Note: 

It shall be 

set to [Y] for UL fire appli-
cations.

[001][04] Supervision - 

Default [Y]

Enables supervision of the 
device. 

Note: 

It shall be set 

to [Y] for UL fire applica-
tions.

Zone EOL - Default [01]

Configures auxiliary input as one of the following options:
[00] Disabled

[01] Single EOL

[02] Normally 
Open. 

Note: 

it 

shall be set for UL 
fire applications.

[03] Normally Closed

N

O

P

Frequency Bands

Maximum Power

868.0MHz - 868.6 MHz

10mW

868.7MHz - 869.2MHz

10mW

433.22MHz - 434.64MHz

10mW

Réponse du voyant

Force du signal 

Le voyant vert clignote

FORT 

Le voyant orange clignote

BON 

Le voyant rouge clignote

FAIBLE 

Aucun clignotement

Aucune communication

B

A

C

D

E

F

+

-

H

I

G

F

+

-

H

I

G

D-307428

Содержание pg9945

Страница 1: ...in the Standards UL 985 resi fire applications and UL634 and ULC ORDC634 for Door and Window Contact For UL ULC installations use this device only in conjunction with compatible DSC wireless receivers HSM2HOST9 HS2LCDRF P 9 HS2ICNRF P 9 PG9920 WS900 19 and WS900 29 Europe The PG8945 is certified by Telefication to the following standards EN50131 2 6 EN50131 1 GRADE 2 CLASS II EN50131 6 Type C Tele...

Страница 2: ...ersonales ADVERTENCIA Peligro de explosión si las baterías están instaladas incorrectamente Reemplace las baterías solamente por el mismo tipo o equivalente recomendado por el fabricante Deseche las baterías usadas según las instrucciones del fabricante Manténgalas alejadas de niños pequeños si son ingeridas consulte inmediatamente a un doctor No intente recargar estas baterías Nota El reemplazo d...

Страница 3: ... de montagem 3 Aperte a base com os 2 parafusos de cabeça cônica 4 Monte a base de ímã com dois parafusos fornecidos 5 Fixe o íman para a base de imã Montar com fita adesiva 1 Remova a película amovível das duas tiras de fita adesiva de dupla face e fixe o dispositivo ao imã 2 Alinhe o dispositivo com o imã conforme as marcas de localização e fixe o imã e o dispositivo à superfície de montagem Fia...

Страница 4: ...ital Security Controls una división de Tyco Safety Products Canada Ltd DSC el fabricante de los sistemas de seguridad integrados y programador del software y de todos los productos o componentes relacionados HARDWARE que usted ha adquirido Si el producto de software DSC PRODUCTO DE SOFTWARE o SOFTWARE necesita estar acompañado de HARDWARE y NO está acompañado de nuevo HARDWARE usted no puede usar ...

Отзывы: