P R O G R A M  D E S C R I P T I O N S

Local Alarm Follower ..................................... Section [30], Option [1]

5.6

Talk/Listen-In

The “Event Buffer follows Swinger Shutdown” option must be enabled in the
PC5010 if Talk/Listen-In is used.

The PC5928 Audio Interface module has built-in Talk/Listen-In capability which can be
activated by zone alarms, keypad activated Auxiliary and Panic alarms, openings/closings,
duress alarms, tamper alarms, or opening after alarm conditions.

In all cases, the PC5010 must be programmed to report the event with communi-
cations enabled.  For example, if a reporting code for a zone is not programmed,
it will not initiate Talk/Listen-In session.

The “Event Buffer Follows Swinger Shutdown” option must be enabled in the PC5010 to
ensure proper Talk/Listen-In operation.

A zone alarm will activate the feature if the zone is assigned to a station (

Zone Assignment

)

and the zone is enabled for Talk/Listen-In (

Audio Control 

options). This is programmable by

zone. If the zone is not enabled in the 

Audio Control 

options,

 

the zone will not initiate Talk/

Listen-In. If the zone is not assigned to a station, the PC5928 will turn on all stations.

All zones programmed as silent will not initiate a Talk/Listen-In session.  Only a
Listen-In session can occur.

Keypad Panic alarms will activate the Listen In feature, if the 

Panic Keys Alarm 

option is

enabled.

Keypad Auxiliary alarms will activate the feature if the 

Auxiliary Keys Alarm 

option is enabled.

Listen in will be initiated if a Duress code is entered at a keypad and the 

Duress Alarm

option is enabled.

Talk/Listen-In will be initiated when the panel transmits opening and closing signals if the
Openings & Closings option is enabled.  If this option is enabled, it is recommended to
enable the Duress Alarm option.

Talk/Listen-In will be initiated when a zone tamper condition occurs if the 

Tampers Enabled

option is enabled.

Module tampers will not initiate a Talk/Listen-In session.

Talk/Listen-In will be initiated when a zone expander supervisory trouble condition occurs if
the 

Zone Expander Supervisory Trouble Alarm 

option is enabled.

Talk/Listen-In will be initiated when the panel is disarmed after an alarm condition (Opening
After Alarm) if the 

Opening After Alarm 

option is enabled.

If the 

Listen To All Stations 

option is enabled the PC5928 will turn on all stations instead of

just the one closest to the zone or keypad.

A Talk/Listen-In session cannot be initiated for a 2-wire smoke or F-key alarm.

firealarmresources.com

Содержание PC5928

Страница 1: ... Call to the In House Phones 7 3 11 Call Waiting 7 3 12 User Help Keypad Function keys 7 3 13 Music Input 8 3 14 Voice Verification 8 Section 4 Programming 8 Section 5 Program Descriptions 5 1 Station Definitions 9 5 2 Zone Port Assignment 9 5 3 Keypad Port Assignment 9 5 4 Broadcast Mask 9 5 5 Alarm Follower 9 5 6 Talk Listen In 10 5 7 Talk Listen In Operation 11 5 8 Listen To All 12 5 9 Page Lis...

Страница 2: ...dule Each station has a separate microphone and speaker Each station must be home run to the interface module using shielded 22 gauge 4 conductor wire Each station can be used to initiate or receive pages answer incoming calls answer the doorbell monitor rooms or sound an alarm follower PC5921EXT Exterior Audio Station The PC5921EXT Exterior Audio Station is housed in a gray fade resistant case de...

Страница 3: ...be done from any Power832 keypad Refer to the Audio Interface Programming Worksheets for program items and options Helpful Installation Tips Feedback If an intercom station appears to be exhibiting feedback noise check the following for potential causes Microphone Remove the backplate The microphone and holder are located in the bottom left corner Ensure that the microphone is pushed fully into th...

Страница 4: ...he drain wire of the shield to the COM terminal on the PC5928 module or the black terminal of the station make sure the drain wire of the shield does not short anything on the back of the board but not both Refer to the diagram below Avoiding Audio Station Interference Noise The Keybus wiring and several different electrical devices fluorescent lighting etc may induce noise onto the intercom wires...

Страница 5: ... panel the following steps must be taken Step 1 At a keypad enter 8 Installer Code to enter Installer Programming Step 2 Press 902 to enable supervision The panel will automatically search for all modules on the system Press to exit Installer Programming The search takes approximately 1 minute From this point on if any modules are removed from the system a Supervisory trouble will be generated Ste...

Страница 6: ...iated by accident pressing the Page Answer button a second time will cancel the Page 3 4 Do Not Disturb To avoid receiving pages doorbox calls or incoming phone calls a station can be put on Do Not Disturb To do this press the Do Not Disturb button on the station The red light on the station will come on solid to indicate the unit is in Do Not Disturb mode To take a station off Do Not Disturb pres...

Страница 7: ...b button The red light on the station will go out 3 9 Answering Incoming Calls When an incoming call is detected the PC5928 will sound a ringing tone on all stations which are enabled to sound the tone unless on Do Not Disturb To answer the call the user must press the Page Answer button for 1 second Once the call is answered the audio channel will operate the same as it does for a Page The call w...

Страница 8: ...connecting the audio source to a microphone input one side of the source to the mic input and the other side to ground The music input must be programmed in the port definitions enter installer s programming section 802 sub section 01 Enter the digits 05 in the appropriate port definition To turn on the music input enter user programming 6 Master Code then press 7 key To turn off the music input f...

Страница 9: ...e alarm Zone Port Assignments must be programmed even if zone alarms are not used Tampers Openings and Closings and all other events will not function if there are NO ports assigned here Zone Port Assignment Section 10 to 13 5 3 Keypad Port Assignment This section is used to program which keypad is closest to which station This is used with the Identified Voice Prompted Help feature described in S...

Страница 10: ...zones programmed as silent will not initiate a Talk Listen In session Only a Listen In session can occur Keypad Panic alarms will activate the Listen In feature if the Panic Keys Alarm option is enabled Keypad Auxiliary alarms will activate the feature if the Auxiliary Keys Alarm option is enabled Listen in will be initiated if a Duress code is entered at a keypad and the Duress Alarm option is en...

Страница 11: ... Once the central station has established the audio link there are several commands available to them for audio control Commands are the touch tone digits 0 through 9 and Additional commands may be programmed as Mode Keys which are two button entries The central station may already be using other Talk Listen In equipment Because of this the PC5928 offers flexible programming for the various comman...

Страница 12: ... will be heard on all other stations which hear pages If the doorbell page is answered by pressing the Page Answer button normal page activity will take place If the doorbell page is not answered it will time out after 30 seconds Doorbell Listens To All Section 30 Option 4 5 11 Telephone Ring Mask Any station type can be enabled to sound a ringing tone when an incoming call is detected If the Tele...

Страница 13: ... 11 l_____l_____l Zone 13 l_____l_____l Zone 15 l_____l_____l Zone 10 l_____l_____l Zone 12 l_____l_____l Zone 14 l_____l_____l Zone 16 12 Zone Port Assignments Zones 17 24 Enter the nearest Intercom Station Number 01 07 00 Not Used Default 00 l_____l_____l Zone 17 l_____l_____l Zone 19 l_____l_____l Zone 21 l_____l_____l Zone 23 l_____l_____l Zone 18 l_____l_____l Zone 20 l_____l_____l Zone 22 l_...

Страница 14: ..._l Option 08 For Future Use Audio Control Telephone Key Functions 00 Key Not Used 09 Terminate Session 01 Talk To All Speakers 10 For Future Use 02 For Future Use 11 Cancel First Keypress 03 High Gain Listen To All 12 For Future Use 04 For Future Use 13 Zone Select 0 3 only 05 For Future Use 14 Increment Selected Microphone Input 06 Low Gain Listen To All 15 Decrement Selected Microphone Input 07 ...

Страница 15: ... Disabled OFF l________l Option 08 Zone 16 Alarm Enabled Disabled 52 Third Audio Control Options Default Option ON Option OFF OFF l________l Option 01 Zone 17 Alarm Enabled Disabled OFF l________l Option 02 Zone 18 Alarm Enabled Disabled OFF l________l Option 03 Zone 19 Alarm Enabled Disabled OFF l________l Option 04 Zone 20 Alarm Enabled Disabled OFF l________l Option 05 Zone 21 Alarm Enabled Dis...

Страница 16: ... Telephone Ring Enabled Disabled OFF l________l Option 06 Port 5 Telephone Ring Enabled Disabled OFF l________l Option 07 Port 6 Telephone Ring Enabled Disabled OFF l________l Option 08 Port 7 Telephone Ring Enabled Disabled 70 Doorstrike Activation Mask Default Option ON Option OFF OFF l________l Option 01 For Future Use OFF l________l Option 02 Port 1 Enabled to Activate Doorstrike Disabled OFF ...

Отзывы: