DSC PC5720 Скачать руководство пользователя страница 32

WARNING 

Please Read Carefully

Note to Installers

This warning contains vital information. As the only individual in contact
with system users, it is your responsibility to bring each item in this warning
to the attention of the users of this system.

System Failures

This system has been carefully designed to be as effective as possible. There
are circumstances, however, involving fire, burglary, or other types of emer-
gencies where it may not provide protection. Any alarm system of any type
may be compromised deliberately or may fail to operate as expected for a
variety of reasons. Some but not all of these reasons may be:

■ 

■ 

■ 

■ 

■ 

Inadequate Installation

A security system must be installed properly in order to provide adequate
protection. Every installation should be evaluated by a security professional
to ensure that all access points and areas are covered. Locks and latches on
windows and doors must be secure and operate as intended. Windows, doors,
walls, ceilings and other building materials must be of suff icient strength
and construction to provide the level of protection expected. A reevaluation
must be done during and after any construction activity. An evaluation by
the fire and/or police department is highly recommended if this service is
available.

■ 

■ 

■ 

■ 

■ 

Criminal Knowledge

This system contains security features which were known to be effective at
the time of manufacture. It is possible for persons with criminal intent to
develop techniques which reduce the effectiveness of these features. It is
important that a security system be reviewed periodically to ensure that its
features remain effective and that it be updated or replaced if it is found that
it does not provide the protection expected.

■ 

■ 

■ 

■ 

■ 

Access by Intruders

Intruders may enter through an unprotected access point, circumvent a
sensing device, evade detection by moving through an area of insuff i-
cient coverage, disconnect a warning device, or interfere with or pre-
vent the proper operation of the system.

■ 

■ 

■ 

■ 

■ 

Power Failure

Control units, intrusion detectors, smoke detectors and many other security
devices require an adequate power supply for proper operation.  If a device
operates from batteries, it is possible for the batteries to fail. Even if the
batteries have not failed, they must be charged, in good condition and in-
stalled correctly. If a device operates only by AC power, any interruption,
however brief, will render that device inoperative while it does not have power.
Power interruptions of any length are often accompanied by voltage fluctua-
tions which may damage electronic equipment such as a security system.
After a power interruption has occurred, immediately conduct a complete
system test to ensure that the system operates as intended.

■ 

■ 

■ 

■ 

■ 

Failure of Replaceable Batteries

This system’s wireless transmitters have been designed to provide several
years of battery life under normal conditions. The expected battery life is a
function of the device environment, usage and type. Ambient conditions such
as high humidity, high or low temperatures, or large temperature fluctua-
tions may reduce the expected battery life. While each transmitting device
has a low battery monitor which identifies when the batteries need to be
replaced, this monitor may fail to operate as expected. Regular testing and
maintenance will keep the system in good operating condition.

■ 

■ 

■ 

■ 

■ 

Compromise of Radio Frequency (Wireless)

Devices

Signals may not reach the receiver under all circumstances which could
include metal objects placed on or near the radio path or deliberate
jamming or other inadvertent radio signal interference.

■ 

■ 

■ 

■ 

■ 

System Users

A user may not be able to operate a panic or emergency switch possibly due
to permanent or temporary physical disability, inability to reach the device
in time, or unfamiliarity with the correct operation. It is important that all
system users be trained in the correct operation of the alarm system and that
they know how to respond when the system indicates an alarm.

■ 

■ 

■ 

■ 

■ 

Smoke Detectors

Smoke detectors that are a part of this system may not properly alert occupants
of a fire for a number of reasons, some of which follow. The smoke detectors
may have been improperly installed or positioned. Smoke may not be able to
reach the smoke detectors, such as when the fire is in a chimney, walls or roofs,
or on the other side of closed doors. Smoke detectors may not detect smoke
from fires on another level of the residence or building.

Every fire is different in the amount of smoke produced and the rate of
burning. Smoke detectors cannot sense all types of fires equally well. Smoke
detectors may not  provide timely warning of fires caused by carelessness
or safety hazards such as smoking in bed, violent explosions, escaping gas,
improper storage of flammable materials, overloaded electrical circuits, chil-
dren playing with matches or arson.

Even if the smoke detector operates as intended, there may be circumstances
when there is insuff icient warning to allow all occupants to escape in time to
avoid injury or death.

■ 

■ 

■ 

■ 

■ 

Motion Detectors

Motion detectors can only detect motion within the designated areas as
shown in their respective installation instructions. They cannot discrimi-
nate between intruders and intended occupants. Motion detectors do not
provide volumetric area protection. They have multiple beams of detec-
tion and motion can only be detected in unobstructed areas covered by
these beams.  They cannot detect motion which occurs behind walls, ceil-
ings, floor, closed doors, glass partitions, glass doors or windows. Any
type of tampering whether intentional or unintentional such as masking,
painting, or spraying of any material on the lenses, mirrors, windows or
any other part of the detection system will impair its proper operation.

Passive infrared motion detectors operate by sensing changes in tempera-
ture. However their effectiveness can be reduced when the ambient tem-
perature rises near or above body temperature or if there are intentional or
unintentional sources of heat in or near the detection area. Some of these
heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sun-
light, steam vents, lighting and so on.

■ 

■ 

■ 

■ 

■ 

Warning Devices

Warning devices such as sirens, bells, horns, or strobes may not warn
people or waken someone sleeping if there is an intervening wall or door.
If warning devices are located on a different level of the residence or
premise, then it is less likely that the occupants will be alerted or awak-
ened.  Audible warning devices may be interfered with by other noise
sources such as stereos, radios, televisions, air conditioners or other ap-
pliances, or passing traff ic. Audible warning devices, however loud, may
not be heard by a hearing-impaired person.

■ 

■ 

■ 

■ 

■ 

Telephone Lines

If telephone lines are used to transmit alarms, they may be out of service or busy
for certain periods of time. Also an intruder may cut the telephone line or defeat
its operation by more sophisticated means which may be diff icult to detect.

■ 

■ 

■ 

■ 

■ 

Insufficient Time

There may be circumstances when the system will operate as intended, yet the
occupants will not be protected from the emergency due to their inability to
respond to the warnings in a timely manner. If the system is monitored, the
response may not occur in time to protect the occupants or their belongings.

■ 

■ 

■ 

■ 

■ 

Component Failure

Although every effort has been made to make this system as reliable as possible,
the system may fail to function as intended due to the failure of a component.

■ 

■ 

■ 

■ 

■ 

Inadequate Testing

Most problems that would prevent an alarm system from operating as in-
tended can be found by regular testing and maintenance. The complete sys-
tem should be tested weekly and immediately after a break-in, an attempted
break-in, a fire, a storm, an earthquake, an accident, or any kind of con-
struction activity inside or outside the premises. The testing should include
all sensing devices, keypads, consoles, alarm indicating devices and any
other operational devices that are part of the system.

■ 

■ 

■ 

■ 

■ 

Security and Insurance

Regardless of its capabilities, an alarm system is not a substitute for prop-
erty or life insurance. An alarm system also  is not a substitute for prop-
erty owners, renters, or other occupants to act prudently to prevent or mini-
mize the harmful effects of an emergency situation.

Содержание PC5720

Страница 1: ...1645 Flint Road Downsview Ontario Canada M3J 2J6 Printed in Canada 29003276 R0 W A R N I N G This manual contains information on limitations regarding product use and function and information on the...

Страница 2: ...w Battery Reporting Codes 11 13 Miscellaneous Option Reporting Codes 11 20 Handheld Keypad Low Battery Reporting Types 11 21 Wireless Key 1 8 Low Battery Reporting Types 11 22 Wireless Key 9 16 Low Ba...

Страница 3: ...orting Types 18 71 Zone 17 24 Alarm Restore Bypass Reporting Types 18 72 Zone 25 32 Alarm Restore Bypass Reporting Types 18 73 Zone 1 8 Tamper Restore Reporting Types 18 74 Zone 9 16 Tamper Restore Re...

Страница 4: ...0mA standby 100mA with printer 120mA with F1 F2 L3 Tamper and Trouble reporting codes Maximum cable length 200 feet 61 meters Eight zone inputs one ground fault detection zone two normally open Class...

Страница 5: ...vely Refer to your panel s Installation Manual for complete instructions on Keybus wiring Zone Input terminals The zone inputs Z10 to Z14 as well as A and B will report as PC5010 zones 10 16 This is n...

Страница 6: ...expanders 1 and 2 zones 9 12 zones 13 16 These three areas of supervision correspond to supervision zone lights 20 printer or 22 alternate communicator 9 and 10 when all modules are displayed by enter...

Страница 7: ...6 PC5720 Wiring Diagram...

Страница 8: ...ormation will be transmitted from the PC5720 module to the serial printer There are four different baud rates available If you are experiencing problems with missing characters try lowering the baud r...

Страница 9: ...ll call 01 response on all call 1 only 02 response on all call 2 only 03 response on both all calls 04 modules with odd numbered ID codes see section 40 respond to All Call 1 Modules with even numbere...

Страница 10: ...that zone 1 is a fire zone Refer to the DVACS Reporting Type tables on pages 24 27 To have the PC5720 transmit a pre programmed code from the internal table leave the programming at the default value...

Страница 11: ...al Printer enabled DVACS enabled OFF I____I Option 2 8 For future use PC5010 and PC5015 Programming Sections If you will be connecting the PC5720 to a PC5010 or PC5015 control panel access the PC5720...

Страница 12: ...ting Types Default Default FF I____I____I Handheld Keypad 1 FF I____I____I For future use FF I____I____I Handheld Keypad 2 FF I____I____I For future use FF I____I____I Handheld Keypad 3 FF I____I____I...

Страница 13: ...16 16 16 16 24 Hour Panic 26 26 26 26 26 24 Hour Non Alarm 07 07 07 07 07 Delayed 24 Hour Fire Hardwired 17 17 17 17 17 24 Hour Emergency 87 87 87 87 87 Delayed 24 Hour Fire Wireless 08 08 08 08 08 St...

Страница 14: ...o All Call 2 E g a module withID code 03 will respond to All Call 1 A module with ID code 04 will respond to All Call 2 42 Miscellaneous Options Default Option ON Option OFF ON I____I Option 1 All Cal...

Страница 15: ...wnlook Module Supv Restore FF I____I____I PC5400 Supv Fault Rest FF I____I____I PC5132 Supervisory Fault Restore FF I____I____I Alt Comm LINKS SupvFlt Rest FF I____I____I PC5208 Supervisory Fault Rest...

Страница 16: ...FF I____I____I Zone 26 FF I____I____I Zone 30 FF I____I____I Zone 27 FF I____I____I Zone 31 FF I____I____I Zone 28 FF I____I____I Zone 32 53 Zone 1 8 Tamper Restore Reporting Codes Default Default FF...

Страница 17: ...e 10 FF I____I____I Zone 14 FF I____I____I Zone 11 FF I____I____I Zone 15 FF I____I____I Zone 12 FF I____I____I Zone 16 59 Zone 17 24 Trouble Restore Reporting Codes Default Default FF I____I____I Zon...

Страница 18: ...30 FF I____I____I Zone 27 FF I____I____I Zone 31 FF I____I____I Zone 28 FF I____I____I Zone 32 65 Keypad Tamper Restore Reporting Codes Default Default FF I____I____I Keypad 1 FF I____I____I Keypad 5...

Страница 19: ...____I____I Zone 9 FF I____I____I Zone 13 FF I____I____I Zone 10 FF I____I____I Zone 14 FF I____I____I Zone 11 FF I____I____I Zone 15 FF I____I____I Zone 12 FF I____I____I Zone 16 71 Zone 17 24 Alarm R...

Страница 20: ...__I Zone 26 FF I____I____I Zone 30 FF I____I____I Zone 27 FF I____I____I Zone 31 FF I____I____I Zone 28 FF I____I____I Zone 32 77 Zone 1 8 Trouble Restore Reporting Types Default Default FF I____I____...

Страница 21: ...FF I____I____I Zone 14 FF I____I____I Zone 11 FF I____I____I Zone 15 FF I____I____I Zone 12 FF I____I____I Zone 16 83 Zone 17 24 Low Battery Restore Reporting Types Default Default FF I____I____I Zon...

Страница 22: ...xpander Module 89 First DVACS Reporting Types Default Default FF I____I____I Duress Alarm FF I____I____I PGM2 Input Alarm Restore FF I____I____I Keypad F Key Alarm Restore FF I____I____I PC5132 Tamper...

Страница 23: ...ifth DVACS Reporting Types Default Default FF I____I____I ESCORT 5580 Supv Fault Restore FF I____I____I System Test FF I____I____I Keypad Lockout FF I____I____I Installer Lead In Lead Out FF I____I___...

Страница 24: ...A WH WB WU 000 999 0E Freeze Alm Rst Byp Unb Zn000 999 ZA ZH ZB ZU 000 999 0F Gas Alm Rst Byp Unb Zn000 999 GA GH GB GU 000 999 10 Heat Alm Rst Byp Unb Zn000 999 KA KH KB KU 000 999 11 24 hrs Alm Rst...

Страница 25: ...eeze Trb T_R Byp Unb Zn000 999 ZT ZJ ZB ZU 000 999 2F Gas Trb T_R Byp Unb Zn000 999 GT GJ GB GU 000 999 30 Heat Trb T_R Byp Unb Zn000 999 KT KJ KB KU 000 999 31 24 hrs Trb T_R Byp Unb Zn000 999 UT UJ...

Страница 26: ...C Motion Sup S_R Byp Unb Zn000 999 BS BJ BB BU 000 999 6D Water Sup S_R Byp Unb Zn000 999 WS WJ WB WU 000 999 6E Freeze Sup S_R Byp Unb Zn000 999 ZS ZJ ZB ZU 000 999 6F Gas Sup S_R Byp Unb Zn000 999 G...

Страница 27: ...1B Fire test begin FI 1C Fire test end FK 1D User cd Tamper JA 1E Log Threshold JL 1F Log Overflow JO 20 Schedul Execute JR 21 Schedul Change JS 22 Time Changed JT Rep Code Printer MSG Computer MSG 23...

Страница 28: ...y 05 85 QA0zz QH0zz 24 Hr Sprinkler 01 81 SA0zz SH0zz 24 Hr Water 0D 8D WA0zz WH0zz 24 Hr Freeze 0E 8E ZA0zz ZH0zz 24 Hr Latching Tamper 16 96 TA0zz TR0zz Interior Delay 08 88 BA0zz BH0zz Duress 03 99...

Страница 29: ...zz 24 Hr Panic 62 E2 PS0zz PJ0zz 24 Hr Emergency 65 E5 QS0zz QJ0zz 24 Hr Sprinkler 61 E1 SS0zz SJ0zz 24 Hr Water 6D ED WS0zz WJ0zz 24 Hr Freeze 6E EE ZS0zz ZJ0zz 24 Hr Latching Tamper 71 F1 US0zz UJ0z...

Страница 30: ...m Rst 20 A0 00 FT000 FJ000 Aux Power Alm Rst 3C BC 01 YP001 YQ001 TLM Alm Rst Links 3E BE 00 LT000 LR000 Phone 1 Alm Rst 3E BE 01 LT001 LR001 Phone 2 Alm Rst 3E BE 02 LT002 LR002 Keybus Fault Alm Rst...

Страница 31: ...CL046 Automatic Closing 7E 01 CA MISCELLANEOUS SYSTEM REPORTS Event Description MT Function Byte Low Zone SIA Message Keypad Lockout 7E 1D JA Remote ESCORT Access 7E 16 DO DLS Lead In Lead Out 7E 2F...

Страница 32: ...not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detec...

Страница 33: ...ich may be revised from time to time will be charged for each unit repaired Products which Digital Security Controls Ltd determines not to be repairable will be replaced by the nearest equivalent prod...

Страница 34: ...1645 Flint Road Downsview Ontario Canada M3J 2J6 Printed in Canada 29003276 R0 W A R N I N G This manual contains information on limitations regarding product use and function and information on the...

Отзывы: