Bypassing Zones

A “bypassed” zone will not cause an alarm.  Zones may be bypassed to allow access to part of the
protected area while other zones are armed.  For example, you could bypass the zone protecting your
living room.  This would allow you to remain in the room, while the other zones on your system are armed.

With the system disarmed, enter [

][1][Access Code] to display bypassed zones.  The Zone Lights

representing bypassed zones will come ON.  Ensure that any zone displayed as being bypassed is
intentionally bypassed.  Zone bypasses are automatically cancelled when the panel is disarmed.

To Bypass Zones:

Enter [

][1][Access Code]; the “System” light will FLASH.

Enter the number of the zone to be bypassed; the corresponding Zone Light will come ON to indicate that
the zone is bypassed.  To remove a bypass, enter the zone number to shut its Zone Light OFF.  When all
desired zones are bypassed, press the [#] Key to return to “Ready”.

When you arm your system, the zones you have indicated will now be bypassed.  When arming the system
with bypassed zones, it is always a good idea to enter the [

][1][Access Code] command to review the list

of bypassed zones before entering an Access Code to arm the system.  After ensuring that the desired
zones are bypassed, press the [#] Key, and then enter an Access Code to arm the system.

Keypad Alarms

Three types of alarms may be activated by pressing and holding a single key on the keypad.  Your
installer will inform you of how the [F], [A] and [P] Keys will operate on your system.

[F]

Press and hold the [F] Key for 2 seconds to sound an [F] Key alarm; the siren will sound with
a pulsed tone.  The keypad will sound a series of short beeps once the system has
accepted the alarm.

[A]

Press and hold the [A] Key for 2 seconds to generate an [A] Key alarm.  The siren will not
sound when this function is activated.  Your installer will inform you of how this alarm will
operate; this alarm may be programmed to activate a device, such as a door lock or a
warning light.  The keypad will sound a series of short beeps once the system has accepted
the alarm.

[P]

Press and hold the [P] Key for 2 seconds to generate a [P] Key alarm.  The alarm may be
programmed as either silent or audible; your installer will inform you of how this alarm will
operate.  If your installer has programmed this alarm to be audible, the keypad will sound a
series of short beeps once the system has accepted the alarm, and the siren will sound a
steady tone.

Utility Output Command

A special keypad command may be used to operate various devices connected to your security system.
To operate the Utility Output, enter [

][7] on the keypad.  When the command is entered, the keypad will

sound a single tone for 5 seconds, and the Utility Output will be activated for 5 seconds.

This command may be used to operate devices such as special lighting or door strikes.  Your installer
will inform you of how the Utility Output function is set up on your system.

Содержание PC56O

Страница 1: ...6O W A R N I N G This manual contains information on limitations regarding product use and functionandinformationonthelimitationsastoliabilityofthemanufacturer The entire manual should be carefully read Security Products TM ...

Страница 2: ...y not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detectors such as when the fire is in a chimney walls or roofs or on the other side of closed doors Smoke detectors may not detect smoke from fires on another level of the residence or building Every fire...

Страница 3: ...ypad Alarms 5 Utility Output Command 5 ARMING OPTIONS 6 At Home Arming 6 Stay Away Arming 6 Quick Arm 6 PC500RK KEYPAD 7 SL 40 KEYPAD 8 DISPLAYING SYSTEM INFORMATION 9 Display Alarm Memory 9 Display Trouble Conditions 9 CHANGING SYSTEM FEATURES 10 Changing Access Codes 10 Door Chime On Off 10 Adjusting the Keypad Sounder Tone and Backlighting 10 TESTING 11 Bell Test 11 Weekly Testing 11 MAINTENANC...

Страница 4: ..._______________________________ Phone ________________________ ZONE INFORMATION Zone Type Protected Area 1 ____________________ _______________________________________________________ 2 ____________________ _______________________________________________________ 3 ____________________ _______________________________________________________ 4 ____________________ ___________________________________...

Страница 5: ...ple straight forward operation Described here are some terms that are used throughout this manual to explain the operation of your system Keypad Your system features one or more PC500RK or SL 40 Keypads The keypad is used to enter commands to operate the system and to view operating information about the system Information about the system is displayed on the Zone Lights labelled 1 through 4 The k...

Страница 6: ...em must be disarmed Go to the keypad and enter an Access Code If an error is made entering the code press the Key and enter the code again When a correct Access Code is entered the Armed light will be shut OFF and the sounder will be silenced your system is now disarmed An Access Code must be entered before the Entry Delay expires or an alarm will sound The factory setting for the Entry Delay is 3...

Страница 7: ...d by pressing and holding a single key on the keypad Your installer will inform you of how the F A and P Keys will operate on your system F Press and hold the F Key for 2 seconds to sound an F Key alarm the siren will sound with a pulsed tone The keypad will sound a series of short beeps once the system has accepted the alarm A Press and hold the A Key for 2 seconds to generate an A Key alarm The ...

Страница 8: ...premises Another household member would still be able to enter the premises through the Entry Exit door without causing an alarm When the Entry Exit door is opened an Access Code would have to be entered to disarm the system To arm the system with Stay Away Arming enter an Access Code and do not open the Entry Exit door When the Exit Delay expires the system will be armed with the Stay Away with D...

Страница 9: ...there is an open zone on the system The zone must be closed or bypassed beforethesystemcanbearmed Ifthe Ready light is OFF and none of the Zone Lights are ON the Tamper Zone has been activated The Armed light will come ON to indicate that the system is armed The Armed light will FLASH to indicate that the system is armed and that there is no Entry Delay on any of the zones The System lightwillcome...

Страница 10: ...to display the zones that have been bypassed be sure that zones are intentionally bypassed before arming the system Use the 2 command to display any trouble conditions be sure to have trouble conditions corrected by your installer as soon as possible Use the 3 command to view the alarms in memory Important Follow the instructions in the manual to test your system weekly Follow the guidelines for c...

Страница 11: ...10 seconds to warn of the trouble condition To silence the sounder press the Key The keypad will be silenced but the System light will remain ON until the trouble condition is cleared To display the trouble conditions enter 2 Trouble conditions are represented with the Zone Lights if a Zone Light comes ON then that trouble condition is present Zone Light Trouble Cause What To Do 1 Battery Trouble ...

Страница 12: ...l FLASH Enter to erase the Access Code When all desired changes are complete press the Key to return to Ready IMPORTANT Do not erase the Master Code If the Master Code is accidentally erased contact your installing company for assistance Door Chime On Off The Door Chime feature causes the keypad to beep whenever an Entry Exit Zone or Instant Zone is activated This feature is useful if the Entry Ex...

Страница 13: ...w the trouble condition 4 Activate each sensor on your system in turn For example open protected doors and windows and walk in areas protected by motion detectors Each Zone Light should come ON when each zone is activated Each Zone Light will be shut OFF when the zone is restored to normal when the door or window is shut or when motion stops in areas protected by motion detectors 5 If they are pro...

Страница 14: ...ulations of dust 2 The Bell Test is designed to test the condition of the back up battery installed with your system Even with frequent testing it is recommended that the back up battery be replaced every three years Contact your installing company for information on replacing the battery 3 For other system devices such as passive infrared ultrasonic or microwave motion detectors glassbreak detect...

Страница 15: ...unit repaired Products which Digital Security Controls Ltd determines not to be repairable will be replaced by the nearest equivalent product avail able at that time The current market price of the replacement prod uct will be charged for each replacement unit Digital Security Controls Ltd warrants the original purchaser that for a period of twelve months from the date of purchase the product shal...

Страница 16: ... 1997 Digital Security Controls Ltd 1645 Flint Road Downsview Ontario Canada M3J 2J6 Printed in Canada 29000867 R1 ...

Отзывы: