Power Supply Module

The PC5200 can be used to provide up to 1.0A of additional current to the

compatible DSC Alarm Controllers, models PC5010, PC5015, PC5020,

PC1864, PC1832 and PC1616. PC1616/1832/1864 v4.1 or higher sup-

ports up to four PC5200 modules.

This installation sheet shall be used with the Installation Manual of the DSC

equipment to which the PC5200 is connected or powered from (e.g. alarm

controller, power supply, etc.).

General

This product meets the requirements of Class II, Grade 2 equipment as per

EN50131-1:2006+A1:2009, EN50131-3:2009 Type B, EN50131-6:2008

Type A. 

Specifications

•Power Supply Type A as per EN50131-6 Standard
•Temperature range: -10ºC to +55ºC
•Relative Humidity: 93% non condensing
•Input ratings: 220V-240Vac, 50/60Hz, 200mA 
•Transformer required, mounted in the same enclosure and permanently

connected

NOTE: 

For installations using the transformer mounted inside the cabinet,

replace the fuse only with same type (20mm) rated 250V/315mA.
•Transformer secondary ratings: 16.5Vac, 40VA 
•Board current draw: 20mA (set and unset state / alarm and non-alarm

state)

•Board dimensions: 145 mm x 83 mm
•AUX output ratings: 12V

DC

, -15%/+15% when Input voltage is between

85% to110% of rated value and output current is between 0.0A - 1.0A

max.

•Resettable fuse (PTC) used on circuit board instead of replaceable fuses
•Output ripple voltage: 600mVp-p max
•No Overvoltage protection devices required on the outputs
•Storage device: rechargeable battery, rated 12V

DC

. Replace battery every

3-5 years

•Battery capacity: 4Ah, 7Ah or 14Ah (2 x 7Ah) max.
•Maximum standby time 24h (when using 14Ah battery capacity and AUX

current limited to 480mA max. Refer to Table 1

•Recharging time: up to 80% in less than 72h
•Low battery trouble indication threshold 11.5V

DC

•Battery deep discharge protection (cut-off at 9.5V

DC

)

NOTE: 

Main control panel and power supply shall be powered from the

same AC mains circuit. Deep discharge protection works only when there is

no voltage on the keybus connection. 

NOTE: 

For EN50131-6:2008 compliant installations, use only one 12V/7Ah

battery for 12h of required standby time (550mA output current).
•Supervision for loss of primary power source (AC Fail) battery fail or bat-

tery low voltage (Battery Trouble) with indication provided on the keypad

Terminal Descriptions

AC

 - Supervised, the PC5200 requires a 16V/40VA transformer. Connect the

primary of the transformer to an unswitched AC source (maximum current

draw is 0.5A) and connect the secondary of the transformer (US market

only) to these terminals. 

AUX+

 - This terminal is used to provide power for devices & modules.

Please refer to Table 1 for maximum ratings. 
Connect the positive lead of powered devices to AUX and the negative to the

proper output terminal (O1 to O4).

TAM

 - This can be used to tamper the cabinet in which the PC5200 is

mounted. Connect a normally closed (NC) switch across TAM and BLK. If

the tamper is not being used connect a piece of wire across TAM and BLK to

remove the trouble condition.

Keybus

- The 4-wire Keybus connection is used by the panel to communi-

cate with the module. Connect the RED, BLK, YEL & GRN terminals to the

RED, BLK, YEL & GRN Keybus terminals on the compatible control panel.

Enclosures

The PC5200 can be installed in the metal enclosures listed below:  
•Model PC5003C (removable door) made of 22Ga steel, painted, dimen-

sions: 248mm(L) x 298mm(W) x 76mm(H), weight: 1500g.

•Model PC5003C (hinged door) made of 1.2mm thick steel, painted,

dimensions: 248mm(L) x 298mm(W) x 76mm(H), weight: 2500g

•Model Power UC1 made of 18Ga steel, painted, dimensions: 315mm(L) x

319mm(W) x 100mm(H), weight: 3150g.

•Model PC4003C made of 18Ga steel, painted, dimensions: 230mm(L) x

180mm(W) x 75mm(D), weight 1050g.

Tamper protection switches can be installed on all enclosures, including

door opening protection and/or removal from the mounting position. Doors

can be secured using screws or keylock. The PC5200 may be installed

within the same metallic cabinet as the alarm controller/power supply

(model Power UC1, PC5003C) or in a separate enclosure (model

PC4003C). Internal and/or external wiring for this module shall be routed,

supported, clamped or secured in a manner that reduces the likelihood of:
•excessive strain on wire and on terminal connections,
•loosening of terminal connections and
•damage of conductor insulation

NOTE: 

For EN50131-1 Grade 2 compliant installations, all unused holes on

the side of the cabinet must be covered (plugged). Also, the security tape

must be applied over the hinges of the removeable door in order to prevent

undetected access to the inside of the cabinet.

NOTE: 

The PC5200 power supply has been certified by Telefication accord-

ing to EN50131-1:2006 + A1:2009 and EN50131-6:2008,  for Grade 2,

Class II, Type A when installed in PC5003C (removable door) enclosure.

PC5200 Jumper Settings

The PC5200 has 2 jumpers; to select which PC5200 slot is to be used refer

to the table below. 

PC5200 v2.0 Installation Instructions

Table 1

UL Residential

UL Commercial

EN50131

PC5200 Current 

Draw 20mA

Burglary

Fire

Burglary

Grade 2 /Class 2

Max. Aux Current 

Draw @12V

DC

1A

550mA

1A

550mA

Transformer 

Requirements

16V, 

40VA

16V, 40VA

16V, 40VA

16.5V, 40VA

(Mounted inside 

cabinet)

Battery 

Requirements

7Ah min

14Ah min 

(2x7Ah)

7Ah min

7Ah min

UL Listed 

Enclosures

PC500C

PC5003C 

(Household Fire 

& Burglary)

CMC-1

PC4050CAR

PC5003C

PUC1

Standby Time (min.) 4 hours

24 hours

4 hours

12 hours

AUX**

NOTE:

 Devices that require 

power from the PC5200 shall be 
UL Listed for the intended 
application and operate over the 
range 11.5 - 12.5VDC.

For battery requirements and
standby time refer to Table 1.

Recommended Battery:

DSC model BD7-12.

TRANSFORMER

16VAC / 40VA PTD 1640

Residential

Burglary

Residential Fire Applications

TO

KEYBUS

BLK

Class 2

120VAC 60Hz

PRIMARY

RED
BLK

YEL

GRN

Table 2

SLOT

J1

J2

PC5200 1

OFF

OFF

PC5200 2

ON

OFF

PC5200 3

OFF

ON

PC5200 4

ON

ON