DSC PC155O Скачать руководство пользователя страница 23

LIMITED WARRANTY

Digital Security Controls Ltd. warrants the original purchaser that for a period of twelve
months from the date of purchase, the product shall be free of defects in materials and
workmanship under normal use. During the warranty period, Digital Security Controls
Ltd. shall, at its option, repair or replace any defective product upon return of the product
to its factory, at no charge for labour and materials. Any replacement and/or repaired
parts are warranted for the remainder of the original warranty or ninety (90) days, which-
ever is longer. The original owner must promptly notify Digital Security Controls Ltd. in
writing that there is defect in material or workmanship, such written notice to be received
in all events prior to expiration of the warranty period.

International  Warranty

The warranty for international customers is the same as for any customer within Canada
and the United States, with the exception that Digital Security Controls Ltd. shall not be
responsible for any customs fees, taxes, or VAT that may be due.

Warranty Procedure

To obtain service under this warranty, please return the item(s) in question to the point of
purchase. All authorized distributors and dealers have a warranty program. Anyone re-
turning goods to Digital Security Controls Ltd. must first obtain an authorization num-
ber. Digital Security Controls Ltd. will not accept any shipment whatsoever for which
prior authorization has not been obtained.

Conditions to Void Warranty

This warranty applies only to defects in parts and workmanship relating to normal use. It
does not cover:

• damage incurred in shipping or handling;

• damage caused by disaster such as fire, flood, wind, earthquake or lightning;

• damage due to causes beyond the control of Digital Security Controls Ltd. such as excessive

voltage, mechanical shock or water damage;

• damage caused by unauthorized attachment, alterations, modifications or foreign objects;

• damage caused by peripherals (unless such peripherals were supplied by Digital Security

Controls Ltd.);

• defects caused by failure to provide a suitable installation environment for the products;

• damage caused by use of the products for purposes other than those for which it was designed;

• damage from improper maintenance;

• damage arising out of any other abuse, mishandling or improper application of the products.

Digital Security Controls Ltd.’s liability for failure to repair the product under this war-
ranty after a reasonable number of attempts will be limited to a replacement of the prod-
uct, as the exclusive remedy for breach of warranty. Under no circumstances shall Digital
Security Controls Ltd. be liable for any special, incidental, or consequential damages
based upon breach of warranty, breach of contract, negligence, strict liability, or any
other legal theory. Such damages include, but are not limited to, loss of profits, loss of
the product or any associated equipment, cost of capital, cost of substitute or replace-
ment equipment, facilities or services, down time, purchaser’s time, the claims of third
parties, including customers, and injury to property.

Disclaimer of Warranties

This warranty contains the entire warranty and shall be in lieu of any and all other
warranties, whether expressed or implied (including all implied warranties of mer-
chantability or fitness for a particular purpose) And of all other obligations or
liabilities on the part of Digital Security Controls Ltd. Digital Security Controls
Ltd. neither assumes responsibility for nor authorizes any other person purporting
to act on its behalf to modify or to change this warranty, nor to assume for it any
other warranty or liability concerning this product.

This disclaimer of warranties and limited warranty are governed by the laws of the
province of Ontario, Canada.

WARNING: Digital Security Controls Ltd. recommends that the entire system be com-
pletely tested on a regular basis. However, despite frequent testing, and due to, but not
limited to, criminal tampering or electrical disruption, it is possible for this product to
fail to perform as expected.

Installer’s Lockout

Any products returned to DSC which have the Installer’s Lockout option enabled and
exhibit no other problems will be subject to a service charge.

Out of Warranty Repairs

Digital Security Controls Ltd. will at its option repair or replace out-of-warranty prod-
ucts which are returned to its factory according to the following conditions. Anyone
returning goods to Digital Security Controls Ltd. must first obtain an authorization num-
ber. Digital Security Controls Ltd. will not accept any shipment whatsoever for which
prior authorization has not been obtained.

Products which Digital Security Controls Ltd. determines to be repairable will be repaired
and returned. A set fee which Digital Security Controls Ltd. has predetermined and which
may be revised from time to time, will be charged for each unit repaired.

Products which Digital Security Controls Ltd. determines not to be repairable will be
replaced by the nearest equivalent product available at that time. The current market
price of the replacement product will be charged for each replacement unit.

WARNING 

Please Read Carefully

Note to Installers

This warning contains vital information. As the only individual in contact with system users, it is
your responsibility to bring each item in this warning to the attention of the users of this system.

System Failures

This system has been carefully designed to be as effective as possible. There are circumstances,
however, involving fire, burglary, or other types of emergencies where it may not provide protection.
Any alarm system of any type may be compromised deliberately or may fail to operate as expected
for a variety of reasons. Some but not all of these reasons may be:

 Inadequate Installation

A security system must be installed properly in order to provide adequate protection. Every installation
should be evaluated by a security professional to ensure that all access points and areas are covered.
Locks and latches on windows and doors must be secure and operate as intended. Windows, doors,
walls, ceilings and other building materials must be of sufficient strength and construction to provide
the level of protection expected. A reevaluation must be done during and after any construction activity.
An evaluation by the fire and/or police department is highly recommended if this service is available.

 Criminal Knowledge

This system contains security features which were known to be effective at the time of manufacture. It is
possible for persons with criminal intent to develop techniques which reduce the effectiveness of these
features. It is important that a security system be reviewed periodically to ensure that its features remain
effective and that it be updated or replaced if it is found that it does not provide the protection expected.

 Access by Intruders

Intruders may enter through an unprotected access point, circumvent a sensing device, evade detection
by moving through an area of insufficient coverage, disconnect a warning device, or interfere with or
prevent the proper operation of the system.

 Power Failure

Control units, intrusion detectors, smoke detectors and many other security devices require an adequate
power supply for proper operation. If a device operates from batteries, it is possible for the batteries to fail.
Even if the batteries have not failed, they must be charged, in good condition and installed correctly. If a
device operates only by AC power, any interruption, however brief, will render that device inoperative
while it does not have power. Power interruptions of any length are often accompanied by voltage fluctua-
tions which may damage electronic equipment such as a security system. After a power interruption has
occurred, immediately conduct a complete system test to ensure that the system operates as intended.

 Failure of Replaceable Batteries

This system’s wireless transmitters have been designed to provide several years of battery life under
normal conditions. The expected battery life is a function of the device environment, usage and type.
Ambient conditions such as high humidity, high or low temperatures, or large temperature fluctuations
may reduce the expected battery life. While each transmitting device has a low battery monitor which
identifies when the batteries need to be replaced, this monitor may fail to operate as expected. Regular
testing and maintenance will keep the system in good operating condition.

 Compromise of Radio Frequency (Wireless) Devices

Signals may not reach the receiver under all circumstances which could include metal objects placed on
or near the radio path or deliberate jamming or other inadvertent radio signal interference.

 System Users

A user may not be able to operate a panic or emergency switch possibly due to permanent or temporary
physical disability, inability to reach the device in time, or unfamiliarity with the correct operation. It
is important that all system users be trained in the correct operation of the alarm system and that they
know how to respond when the system indicates an alarm.

  Smoke  Detectors

Smoke detectors that are a part of this system may not properly alert occupants of a fire for a number of
reasons, some of which follow. The smoke detectors may have been improperly installed or positioned.
Smoke may not be able to reach the smoke detectors, such as when the fire is in a chimney, walls or
roofs, or on the other side of closed doors. Smoke detectors may not detect smoke from fires on another
level of the residence or building.
Every fire is different in the amount of smoke produced and the rate of burning. Smoke detectors cannot
sense all types of fires equally well. Smoke detectors may not provide timely warning of fires caused by
carelessness or safety hazards such as smoking in bed, violent explosions, escaping gas, improper stor-
age of flammable materials, overloaded electrical circuits, children playing with matches or arson.
Even if the smoke detector operates as intended, there may be circumstances when there is insufficient
warning to allow all occupants to escape in time to avoid injury or death.

  Motion  Detectors

Motion detectors can only detect motion within the designated areas as shown in their respective instal-
lation instructions. They cannot discriminate between intruders and intended occupants. Motion detec-
tors do not provide volumetric area protection. They have multiple beams of detection and motion can
only be detected in unobstructed areas covered by these beams. They cannot detect motion which
occurs behind walls, ceilings, floor, closed doors, glass partitions, glass doors or windows. Any type of
tampering whether intentional or unintentional such as masking, painting, or spraying of any material
on the lenses, mirrors, windows or any other part of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature. However their effective-
ness can be reduced when the ambient temperature rises near or above body temperature or if there are
intentional or unintentional sources of heat in or near the detection area. Some of these heat sources
could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on.

 Warning Devices

Warning devices such as sirens, bells, horns, or strobes may not warn people or waken someone sleeping
if there is an intervening wall or door. If warning devices are located on a different level of the residence
or premise, then it is less likely that the occupants will be alerted or awakened. Audible warning devices
may be interfered with by other noise sources such as stereos, radios, televisions, air conditioners or
other appliances, or passing traffic. Audible warning devices, however loud, may not be heard by a hearing-
impaired person.

 Telephone Lines

If telephone lines are used to transmit alarms, they may be out of service or busy for certain periods
of time. Also an intruder may cut the telephone line or defeat its operation by more sophisticated
means which may be difficult to detect.

 Insufficient Time

There may be circumstances when the system will operate as intended, yet the occupants will not be
protected from the emergency due to their inability to respond to the warnings in a timely manner. If the
system is monitored, the response may not occur in time to protect the occupants or their belongings.

 Component Failure

Although every effort has been made to make this system as reliable as possible, the system may fail
to function as intended due to the failure of a component.

  Inadequate  Testing

Most problems that would prevent an alarm system from operating as intended can be found by
regular testing and maintenance. The complete system should be tested weekly and immediately after
a break-in, an attempted break-in, a fire, a storm, an earthquake, an accident, or any kind of construction
activity inside or outside the premises. The testing should include all sensing devices, keypads, con-
soles, alarm indicating devices and any other operational devices that are part of the system.

 Security and Insurance

Regardless of its capabilities, an alarm system is not a substitute for property or life insurance. An alarm
system also is not a substitute for property owners, renters, or other occupants to act prudently to
prevent or minimize the harmful effects of an emergency situation.

Содержание PC155O

Страница 1: ...G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read Software Version 4 1 DLS 1 V6 5 and later ...

Страница 2: ...ering 12 30 Reset to Factory Default 12 31 4th System Option Code 12 32 5th System Option Code 12 33 Answering Machine Double Call Timer 12 34 6th System Option Code 12 35 LINKS1000 Test Reporting Code 12 36 Keypad Lockout Control 13 90 Installer s Lockout Enable 13 91 Installer s Lockout Disable 13 Guidelines for Locating Smoke Detectors 13 For the Record 14 Programming Worksheets 15 PC1550 Contr...

Страница 3: ...e printed circuit board the mounting hardware and the keypad from the cardboard retainer inside the cabinet Before attaching the cabinet to the wall press the four white nylon printed circuit board mounting studs into the cabinet from the back Once the cabinet is mounted to the wall pull all the cables into the cabinet and prepare them for connection Use a meter to test the wiring for opens shorts...

Страница 4: ...current draw of 35 mA per keypad This represents the panel in the disarmed state with two zones open Fire Zone Wiring Any one of the 6 zones may be programmed as a Fire Loop See Programming Guide section 11 Z1 COM Z2 NC NO NC NC END OF LINE RESISTOR 1kΩ 0 5W END OF LINE RESISTOR 1kΩ 0 5W EOL RESISTOR LOOPS USING NO NC DEVICES EOL RESISTOR LOOPS USING NC DEVICES ONLY NOTE For UL installations zone ...

Страница 5: ...n program the panel to prevent the user from being able to bypasscertainzones LightsforthesezoneswillnotcomeONinresponse to the bypass command See Zone Bypass Mask section 16 Trouble Conditions 2 The PC1550 continuously monitors a number of trouble conditions If one of these conditions occurs the keypad Trouble light will come ON and the buzzer will sound two short beeps every 10 seconds To silenc...

Страница 6: ...ss code When the correct command is entered the keypad sounder and the PGM output will operate for 5 seconds be programmed with the downloading computer s telephone number the downloading access code and the panel identification code NOTE 4 command can be programmed to require an access code e g 4 access code in section 14 option 4 User Programming Commands 5 Pressing 5 allows the user to program ...

Страница 7: ...memory which is accessible using the Installer s Programming code or via downloading If the Installer s code is forgotten the EEPROM may be reset to the factory default code See Section 30 Reset to Factory Default Programming With the panel in the disarmed mode enter 8 1500 The panel can only be programmed while it is in disarmed mode The default installer s code is 1500 it can be changed in secti...

Страница 8: ...e second account code is always transmitted to the 2nd telephone number See 02 for programming instructions 05 to 10 Reporting Codes These sections are used to program the communicator reporting codes A reporting code is transmitted along with the account code with each transmission If the reporting codes are not programmed no transmission will be sent when an event takes place i e alarm restoral ...

Страница 9: ...y for the report must be entered in section 19 NOTE For UL installations either AC failure or battery trouble reporting must be enabled 11 Zone Definitions As in the reporting codes sections once this section is entered 6 2 digit numbers are required Each 2 digit number entered defines how a zone will operate Zone Definitions Digit 1 The first digit determines whether the zone will cause a silent ...

Страница 10: ...liary delay loop will not become active until both the auxiliary exit delay has expired and the loop is closed 8 Fire Loop Although a common fire signal is reported any one of the 6 zones may be programmed as a fire loop A fire loop is a supervised N O alarm initiating contacts end of line resistor circuit designed to accept latching 4 wire smoke detectors See the Control Panel Wiring Diagram On a...

Страница 11: ...tion Variables Once this section is entered two 2 digit numbers are expected Do not press while entering data The first 2 digit number defines the number of attempts alarm and restoral pairs per zone that the communicator will make before it shuts down for that zone swinger shutdown The number of attempts is for the period as defined in the 1st System Option Code Section zone light 2 The number of...

Страница 12: ...emove power from the devices connected The keypad buzzer will sound for the 5 second period 05 Courtesy Pulse This option provides an output which follows the entry and exit times It can be used to turn on a courtesy light near the exit door for the duration of the entry exit times 06 Keypad Buzzer Follow Mode The PGM output will go low as long as the keypad buzzer is ON for 24 Hour Buzzer Zone Do...

Страница 13: ... to answer before the answering machine the answering machine will be unable to receive incoming calls 32 5th System Option Code Use the same method of programming as section 12 ZONE LIGHT 1 ON Loss of AC will not cause an AC trouble OFF Loss of AC will cause AC trouble 2 ON No bell during Auto Arm burst every 10 seconds is silenced OFF 1 burst of bell siren every 10 seconds during Auto Arm pre al...

Страница 14: ... quantities of smoke precede detectable levels of heat in most cases For these reasons smoke detectors should be installed outside of each sleeping area and on each additional story of the dwelling The following information is for general guidance only The smoke detector manufacturer s literature should be consulted for detailed installation instructions On smooth ceilings detectors may be spaced ...

Страница 15: ...__________________________________ ZONES Zone Type Protected Area 1 _____________________________ _________________________________________________________________________ 2 _____________________________ _________________________________________________________________________ 3 _____________________________ _________________________________________________________________________ 4 ______________...

Страница 16: ... Zone 3 Restoral Zone 6 Restoral 07 Closing Arming Reporting Codes Partial Closing Reporting Code Page 9 Access Code 1 Access Code 4 Access Code 2 Access Code 5 Access Code 3 Access Code 6 Partial Closing Code 08 Opening Disarming Reporting Codes After Alarm Reporting Code Page 9 The after alarm code is sent on disarming if an alarm occured during the previous armed period Access Code 1 Access Cod...

Страница 17: ...esistor loops ON Zone Light 6 Keypad P anic audible bell Keypad P anic silent bell 13 2nd System Option Code Page 11 Default Zone Light ON Zone Light OFF ON Zone Light 1 Call 1st phone only Backup to 2nd phone1 1 1 1 1 OFF Zone Light 2 Master Code not changeable Master Code changeable OFF Zone Light 3 Bell Squawk enabled2 2 2 2 2 Bell Squawk disabled OFF Zone Light 4 PC16 OUT enabled PC16 OUT disa...

Страница 18: ...ON Zone Light 4 ON Zone Light 2 ON Zone Light 5 ON Zone Light 3 ON Zone Light 6 17 System Times Page 11 Default Default 0 3 0 Entry Delay seconds 0 3 0 AC fail transmission delay minutes 1 2 0 Exit Delay seconds 0 5 0 Slow loop response time x 10 ms 0 0 4 Bell Cut off minutes 0 3 0 Test transmission cycle or auto download cycle time days Valid entries are 001 to 255 Do not enter 000 Do not enter 0...

Страница 19: ...seconds 7 08 Strobe Output latched alarm output 03 Utility Output Any Access Code 5 seconds 7 09 Failure to Communicate Output follows trouble 4 04 5 Second Reset Pulse 7 0A PGM ON during Entry Delay 05 Courtesy Pulse follows entry exit times 0B PGM ON during Exit Delay 06 Keypad Buzzer Follow Mode 0C LINKS1000 Interface 06 Buzzer follows the entry delay door chime auto arm alert period and 24 hou...

Страница 20: ...lay normal ON Zone Light 6 Standard Fire Temporal Fire 33 Answering Machine Double Call Timer Page 14 Default 0 6 0 Valid entries are 001 to 249 34 6th System Option Code Page 14 Default Zone Light ON Zone Light OFF OFF Zone Light 1 Audible Exit Delay with Urgency Standard Exit Delay OFF Zone Light 2 Bell Squawk during Exit Delay No Bell Squawk during Exit Delay OFF Zone Light 3 Audible Exit Fault...

Страница 21: ...g Diagram Incorrect connections may result in PTC failure or improper operation Inspect wiring and ensure connections are correct before applying power Do not route any wiring over circuit boards Maintain at least 1 25 4mm distance ...

Страница 22: ...esolve Radio Television Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 Important Information This equipment complies with Part 68 of the FCC Rules On the side of this equipment is a labelthatcontains amongotherinformation theFCCregistrationnumberofthisequipment Notification to Telephone Company Uponrequest thecusto...

Страница 23: ...reduce the effectiveness of these features It is important that a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected Access by Intruders Intruders may enter through an unprotected access point circumvent a sensing device evade detection by moving through an area of ...

Страница 24: ... 2001 Digital Security Controls Ltd Toronto Canada www dsc com Printed in Canada 29003080 R003 1 800 387 3630 ...

Отзывы: