14
Telephone Terminals
“T I P ”, “R N G ”, “ T-1” a n d “R-1”
The wires from the RJ31-X telephone jack are connected
to these terminals in the following way.
Note: For proper operation, there must be no other
telephone equipment connected between the
control panel and the telephone company’s
facilities.
Ensure that plugs and jacks meet the dimension,
tolerance and metallic plating requirements of 47
C.F.R. Part 68 Subpart F.
TIP
Green wire
Incoming line from
RNG
Red wire
telephone company
T-1
Brown wire
Outgoing line to
R-1
Grey wire
house telephone(s)
Battery Connections
Do not connect the battery or the transformer until the
wiring is complete. Connect the red battery lead to the
positive battery terminal and the black lead to the negative
battery terminal. If the connection is reversed the battery
fuse will blow.