background image

8

E N R O L L  &  P R O G R A M  D E V I C E S

3.3  Enroll & Program Wireless Keys
(WLS909)

For wireless keys to work on the system, you need to
enroll them and then program the function buttons.
Wireless keys are not assigned to zones and require
no zone programming. You can enroll up to 16
wireless keys on the system.

Enroll Wireless keys

1. At a system keypad, enter [

][8][Installer’s code]

to go to the Installer’s Programming section.

2. Enter programming section [804].

3. Enter a 2-digit number [41]-[56] to assign the

wireless key a slot. These numbers correspond
to wireless key numbers 01-16.

4. Enter the key’s ESN. The entry 

must be six digits.

If an older key with a 5-digit ESN is being enrolled,
add the digit [0] to the beginning of the ESN. (E.g.
ESN=61234, enter 061234)

5. The key is now enrolled on the system. Record

the serial number and the assigned slot number
in the programming worksheets in the back of this
manual.

6. Repeat steps 3 - 5 until all wireless keys have

been enrolled.

7. (PC5010 and PC5015 only)

(PC5010 and PC5015 only)

(PC5010 and PC5015 only)

(PC5010 and PC5015 only)

(PC5010 and PC5015 only) By default, all
wireless keys are assigned to Partition 1. To assign
keys to Partition 2, enable the appropriate options
in programming sections [91] and [92].

NOTE: A wireless key can only be assigned to one
partition.

8. To exit press [#].

Program the WLS909 Function Buttons

WLS909 wireless keys have four programmable
function buttons. You must program a set of four
functions for the buttons before any keys will work.
After the functions are programmed, when you press
and hold one of the four buttons for two seconds, the
system will execute the programmed function.

For systems not using partitions:

 program the

function buttons in section [59]. All wireless keys will
have the same four functions.

For systems using 2 partitions (PC5010 and
PC5015 only):

 all wireless keys assigned to Partition

1 will have the four functions programmed in section
[59]. All wireless keys assigned to Partition 2 will
have the four functions programmed in section [60].
For example, if function button 1 in Section [59] is
programmed for Stay arming, then pressing the first
button on wireless keys assigned to Partition 1 will
Stay arm Partition 1.

NOTE: Wireless keys will not work when the partition
they are assigned to is being accessed for zone
bypassing or programming.

1. At a system keypad, enter [

][8][Installer’s code].

2. Enter programming section [804].

3. Enter programming section [59] for keys assigned

to partition 1, or [60] for keys assigned to partition 2.

4. For each of the 4 function buttons, enter the 2-

digit number of the function you want to select.
See the programming worksheets for a list of
function key options.

5. Record your programming choices in the

worksheets in the back of the manual.

6. To exit press [#].

3.4  Identified Wireless Keys

Reporting by the system of openings/closings by
individual wireless keys and command output
[Q][7] activation by wireless key buttons may be
supported on certain control panels. To do this, the
system will reserve access codes 17 – 32 for
wireless keys 01-16 respectively. You must program
one access code for each wireless key (using
[Q][5] access code programming) for this feature to
work correctly.

Refer to your system Installation Manual for
information on access code programming.

Содержание LCD5501Z32-900

Страница 1: ...LCD5501Z32 900 WARNING Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manuf...

Страница 2: ...her warranties whether expressed or implied including all implied warranties of merchantability or fitness for a particular pur pose And of all other obligations or liabilities on the part of Digital...

Страница 3: ...s 8 3 4 Identified Wireless Keys 8 3 5 Enrolling Programming Handheld Keypads 9 3 6 Deleting Wireless Devices 10 Section 4 Other Programming 11 4 1 Program Zones and Partitions 11 4 2 Enable Receiver...

Страница 4: ...her Specifications and Features Current Draw 260mA Frequency 922 to 926 MHz Spread Spectrum Zones receiver can receive signals from up to 32 wireless zones Supervisory programmable supervisory window...

Страница 5: ...ne wire from the device to the Z terminal and the other wire from the device to the B black terminal For powered devices run the red wire to the R positive terminal and the black wire to the B negativ...

Страница 6: ...02 The panel will now supervise all assigned keypads and enrolled modules on the system To review which modules the control panel is currently supervising 1 Enter 8 Installer s Code 2 Enter 903 to dis...

Страница 7: ...You can change the function of each key on every keypad Please see your system s Installation Manual for instructions on programming the keys and a complete list of all the function key options availa...

Страница 8: ...ou are finished press to exit 2 6 Door Chime Options You can program the LCD5501Z32 900 keypad to sound a tone when any zone is opened or closed There are two parts to the LCD5501Z32 900 door chime pr...

Страница 9: ...he door chime sounds 1 Enter 8 Installer s code 2 Enter to go to door chime sound programming 3 Enter a 2 digit number for the zone you want to program 01 32 4 Turn one of the following options on by...

Страница 10: ...ition programming see section 4 Enroll Program Devices This section describes how to enroll and program wireless devices using zones WLS904 WLS905 WLS906 WLS907 WLS908 and WLS915 wireless keys WLS909...

Страница 11: ...you press and hold one of the four buttons for two seconds the system will execute the programmed function For systems not using partitions program the function buttons in section 59 All wireless key...

Страница 12: ...med as 7 1 4 in sections 141 to 154 3 5 Enrolling Programming Handheld Keypads WLS910 For handheld keypads to work on the system you need to enroll them and then program the function buttons You can e...

Страница 13: ...uttons or for partition 2 function buttons 4 For each of the 4 function buttons enter the 2 digit number of the function you want to select See the programming worksheets for a list of function button...

Страница 14: ...nes to be su pervised If normally Closed or Single EOL resistors are selected the PC5010 will not be able to supervise the wireless devices If a wireless device stops S E C T I O N 4 Other Programming...

Страница 15: ...Enter the 2 digit number of the RF Jam Detect zone 01 to 32 in the programming section 4 Disable supervision for the RF Jam detect zone by turning the relevant option off in section 82 83 84 or 85 Se...

Страница 16: ...the device 6 Read the test results at the keypad Result LED Keypad LCD Keypad Buzzer Bell Good Light 1 On Steady Good 1 Beep Squawk Fair Light 2 On Steady Fair 2 Beeps Squawks Bad Light 3 On Steady Ba...

Страница 17: ...your Installation Manual for information on global and partition keypads 3 Press and hold the Test button on the pendant for two seconds 4 If the pendant s battery condition is normal the Ready light...

Страница 18: ...Device Low Battery trouble The user should be instructed to test this device every week See section 5 4 for testing instructions The system will delay reporting the event to the central station for t...

Страница 19: ...or more information on testing devices Verify that you are testing the correct zone Verify that the correct ESN was entered when the device was enrolled Verify that the device is in range of the LCD55...

Страница 20: ...00 Keypad Options Default Option On Off ON I _ ___ ____I 1 Local Clock Display Enabled Local Clock Display Disabled ON I _ ___ ____I 2 Local Clock Displays AM PM Local Clock Displays 24 hour Time OFF...

Страница 21: ..._ I I _ _ _ _ _ _ _ _ I I _ _ _ _ _ _ _ _ I 16 I _ _______ __________________________________________________________I I _ _ _ _ _ _ _ _ I I _ _ _ _ _ _ _ _ I I _ _ _ _ _ _ _ _ I I _ _ _ _ _ _ _ _ I 1...

Страница 22: ...10 l_____l_____l_____l_____l_____l_____l 11 Zone 11 l_____l_____l_____l_____l_____l_____l 12 Zone 12 l_____l_____l_____l_____l_____l_____l 13 Zone 13 l_____l_____l_____l_____l_____l_____l 14 Zone 14 l...

Страница 23: ...__l_____l_____l_____l_____l 52 Key 12 l_____l_____l_____l_____l_____l_____l 53 Key 13 l_____l_____l_____l_____l_____l_____l 54 Key 14 l_____l_____l_____l_____l_____l_____l 55 Key 15 l_____l_____l_____...

Страница 24: ...unction Key 2 l____l____l Function Key 4 l____l____l Supervision 81 Wireless supervisory Window Default 03 l____l____l wireless device window hours valid entries are 01 24 NOTE Panic pendants are NOT...

Страница 25: ...Disabled l________l Option 2 Zone 18 Supervision enabled Disabled l________l Option 3 Zone 19 Supervision enabled Disabled l________l Option 4 Zone 20 Supervision enabled Disabled l________l Option 5...

Страница 26: ...Key 05 on partition 2 On partition 1 l________l Option 6 Wireless Key 06 on partition 2 On partition 1 l________l Option 7 Wireless Key 07 on partition 2 On partition 1 l________l Option 8 Wireless K...

Страница 27: ...detector should be located on each story of the living unit Figure 2 In the family living units with more than one sleeping area a smoke detector should be located to protect each sleeping area Figure...

Страница 28: ...ke detectors that are a part of this system may not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improp erly installed or positione...

Отзывы: