11  Specifications

!

Specifications are subject to change without prior notice.

FCC COMPLIANCE STATEMENT

FCC ID: F5309LC171 

CAUTION: Changes or modifications not expressly approved by Digital 
Security Controls could void your authority to use this equipment.  

This equipment generates and uses radio frequency energy and if not 
installed and used properly, in strict accordance with the manufacturer’s 
instructions, may cause interference to radio and television reception. It 
has been type tested and found to comply with the limits for Class B 
device in accordance with the specifications in Subpart "B" of Part 15 of 
FCC Rules, which are designed to provide reasonable protection against 
such interference in any residential installation. However, there is no 
guarantee that interference will not occur in a particular installation. If 
this equipment does cause interference to television or radio reception, 
which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the 
following measures: 

· Re-orient the receiving antenna 
· Relocate the alarm control with respect to the receiver 
· Move the alarm control away from the receiver 
· Connect the alarm control into a different outlet so that alarm control 
and receiver are on different circuits. 

If necessary, the user should consult the dealer or an experienced 
radio/television technician for additional suggestions. The user may find 
the following booklet prepared by the FCC helpful: "How to Identify and 
Resolve Radio/Television Interference Problems". This booklet is 
available from the U.S. Government Printing Office, Washington, D.C. 
20402, Stock # 004-000-00345-4. 

INDUSTRY CANADA COMPLIANCE STATEMENT

IC:160A-LC171 

The term ‘IC:’ before the radio certification number only signifies that 
Industry Canada technical specifications were met.
This Class B digital apparatus complies with Canadian ICES-003 
Cet appareil numérique de la classe B est conforme à la norme 
NMB-003 du Canada.

RTTE Compliance Statement: 

Detection Method

Dual PIR AND MW  

Microwave Frequency 

24.125 GHz 

Power Input 

9.6  to 16Vdc 

Current Draw

Active: 

24mA (±5%)

Standby:

 21mA (±5%) 

Temp Compensation 

Yes, Dual slope temperature compensation 

Alarm Period 

2 sec (±0.5sec) 

Alarm Outputs 

Form C (NC, NO, Common) 
28Vdc 0.1 A with 10 Ohm series protection resistor 

Tamper Switch(s) 

Two Switches 
N.C 28Vdc 0.1 A with 10 Ohm Series protection resistors 
Opens when cover is removed from unit’s base  or if base is removed from 
wall

Warm up Period 

120sec (± 5sec) 

LED Indicator 

LED is ON during ALARM (configurable) 

RF Immunity 

10 V/m plus 80% AM from 80 MHz to 2GHz 

ElectroStatic Immunity 

6kV contact, 8kV air 

Transient Immunity 

1kV

Operation Temp 

-35ºC ~ +55ºC (-31°F ~ +131°F) 

Dimensions 

200mm x 86mm x 80mm (7.8" x 3.4" x 3.2") 

Weight 

500gr. (1.1 lb) 

European directives 

RTTE directive:1999/5/EC 
EMC directive: 2004/108/EC 
Low Voltage directive: 2006/95/EC 
RoHS directive: 2002/95/EC 

European standards 
requirements: 

EN300 440-2; EN301 489-1; EN50130-4 +A1 +A2; EN61000-6-3+A11 
EN60950-1 
EN50131-1  /  EN50131-2-4  /   EN50130-5 

USA & Canada 

47CFR part 15, subpart C, section 15.245; 47CFR part 15, subpart B 
RSS210; ICES-003   

Protection Degree 

IEC 60529: IP 65  

EN

Содержание LC-171

Страница 1: ...1 INSTALLATION INSTRUCTIONS USER MANUAL P N 7131691 ver B LC 171 Dual Tech Motion Sensor Dual PIR Microwave with Pet Immunity ...

Страница 2: ...Detector Installation 7 7 Terminal Block Connections 9 7 1 Wire Size Requirements 9 8 Settings Adjustments 10 8 1 Detection beam direction 10 8 2 Detection range setting 10 8 3 Sensitivity Range and Pet immunity Adjustment 11 8 4 Indications setting 13 9 Operation 14 10 Test procedure 14 11 Specifications 15 ...

Страница 3: ...ed by a digital rotary switch allowing 16 calibration levels so that the correct detection pattern will be set for every installation The LC 171 is designed to protect large areas and can easily be installed on walls or poles in order to provide a solid area of protection while rejecting interference from birds and small animals due to the provided pet immunity optics 2 Features Microwave detectio...

Страница 4: ...les using the supplied metal bands The LC 171 is combined of three detection elements Upper PIR element Lower PIR element Microwave element The upper PIR element has an adjustable detection height while the other two are fixed The following drawing shows all internal elements Upper PIR element Lower PIR element Microwave element LED Terminal Connection Blocks LED and Buzzer dipswitches Sensitivity...

Страница 5: ...beams A Lower PIR element which is fixed to 18m 59 ft range and 60cm 2 ft above ground level which helps avoiding pet detection over the entire area B Upper PIR element which has adaptive range between 3 and 18m 10 and 59 ft An intrusion is defined by both PIR detection beams being crossed and a Microwave detection occurring causing an alarm No alarm will be generated if only one of the PIR detect...

Страница 6: ...Facing metal doors Near direct sources of heat or airflow Clear all physical obstacles from the detection area e g plants laundry etc Clear all light reflecting surfaces from the detection area including puddles or other standing water Avoid installation on the following types of ground Thick vegetation Grass un mown Water Sand and Metal NOTES Recommended installation height is 1 2m 4ft The DUAL F...

Страница 7: ...etal bracket to a leveled straight and firm wall leaving 15cm 5 9 inches from the top and 15cm from both sides for easy installation and maintenance 4 Rotating the detection beam may be required for guarding a side window opening while the detector is installed facing another direction 5 Open the detector unwinding the bottom screw 6 Release the rear metal bracket by unwinding internal bottom scre...

Страница 8: ...etector 10 Attach the sealing U shaped Sponge Pad to the wire opening from the rear side after the wires have been connected and prior to final product affixing to the mounted bracket 11 Place the detector on the mounting bracket from top side down and then lock the screw at the bottom 12 Connect the wires to the terminal blocks according to the following chapter ...

Страница 9: ...r is detached from installation wall an immediate alarm signal will be sent to the Control Panel Terminal 5 Marked EOL End of line optional terminal for end of line resistors connections Terminals 6 7 8 Marked NC C NO These are the output relay contacts of the detector Connect to a zone input on the control unit When an intruder is detected alarm relays N C and N O will switch for 1 8 sec 7 1 Wire...

Страница 10: ... detection beam direction rotate the internal detection element housing to the desired direction 8 2 Detection range setting The LC 171 detection range may vary between 3m 10 ft and 18m 59 ft while installed on 1 2m 4 ft height above the ground surface Changing the detection range is achieved by sliding the upper detection element up or down ...

Страница 11: ...tch Changing the sensitivity affects immunity to environmental noises and also affects the detection distance and pet immunity level The rotating switch is marked with digits from 0 to 9 and following letters from A to F Position 0 is maximum sensitivity and F is minimum sensitivity Note Adjust sensitivity according to environmental conditions Group A positions 0 5 set sensitivity for 18m detectio...

Страница 12: ...erence from parking garages parking spaces playgrounds football fields service roads etc Risk Stable environment with some trees bushes flowerpots planters High risk Unstable environment with different types of vegetation and grass and puddles Very high risk Unstable environment with winds and small pets rats mice birds Noisy area Unstable environment with vegetation and water sources like swimmin...

Страница 13: ... intrusion has occurred When the Buzzer indicator is ON the Buzzer will activate for 1 8sec each time an intrusion is detected When the Buzzer indicator is OFF the buzzer will not be used to indicate an intrusion has occurred Setting the buzzer ON gives the installer the ability to have audible confirmation of intrusion detection during the adjustments and a walk test After completing adjustments ...

Страница 14: ...ce installed the unit should be thoroughly tested to verify proper operation and coverage After installation the unit should be tested annually by the installer The end user should be instructed on how to perform a weekly walk test Ensure that the detector has completed the 2 minute warm up period before walk testing Make sure that the protected area is cleared of all people Create motion in the e...

Страница 15: ...the FCC helpful How to Identify and Resolve Radio Television Interference Problems This booklet is available from the U S Government Printing Office Washington D C 20402 Stock 004 000 00345 4 INDUSTRY CANADA COMPLIANCE STATEMENT IC 160A LC171 The term IC before the radio certification number only signifies that Industry Canada technical specifications were met This Class B digital apparatus compli...

Страница 16: ...th the purchase installation or operation or failure of this product Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discriminate between intruders and intended occupants Motion detectors do not provide volumetric area protection They have multiple beams of detection and motion can only be detected in unobstruct...

Отзывы: