15
12 Specifications
•
Specifications are subject to change without prior notice.
FCC COMPLIANCE STATEMENT
FCC ID: F5309LC151
CAUTION: Changes or modifications not expressly approved by Digital
Security Controls could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed
and used properly, in strict accordance with the manufacturer’s instructions,
may cause interference to radio and television reception. It has been type
tested and found to comply with the limits for Class B device in accordance with
the specifications in Subpart "B" of Part 15 of FCC Rules, which are designed
to provide reasonable protection against such interference in any residential
installation. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause interference to television or
radio reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the
following measures:
· Re-orient the receiving antenna
· Relocate the alarm control with respect to the receiver
· Move the alarm control away from the receiver
· Connect the alarm control into a different outlet so that alarm control and
receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced
radio/television technician for additional suggestions. The user may find the
following booklet prepared by the FCC helpful: "How to Identify and Resolve
Radio/Television Interference Problems". This booklet is available from the
U.S. Government Printing Office, Washington, D.C. 20402, Stock #
004-000-00345-4.
INDUSTRY CANADA COMPLIANCE STATEMENT
IC:160A-LC151
The term ‘IC:’ before the radio certification number only signifies that Industry
Canada technical specifications were met.
This Class B digital apparatus complies with Canadian ICES-003
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.
RTTE Compliance Statement:
Detection Method
PIR AND MW
Microwave Frequency
X-band (9.9GHz / 10.525GHz / 10.687GHz)
Power Input
9.6 to 16Vdc
Current Draw
Active: 24mA (±5%); Standby: 21mA (±5%)
Temp Compensation
Dual slope temperature compensation
Alarm Period
2 sec (±0.5sec)
Alarm Outputs
Form C (NC, NO, Common)
28Vdc 0.1 A with 10 Ohm
Tamper Switch(s)
Two Switches
N.C 28Vdc 0.1 A with 10 Ohm Series protection resistors
Opens when cover is removed from unit’s base or if base is removed from wall
Warm up Period
30sec (± 5sec)
LED Indicator
Green LED for PIR detection
Yellow LED for Microwave detection
Red LED for alarm condition
All LEDs are ON during ALARM
RF Immunity
10 V/m plus 80% AM from 80 MHz to 2GHz
ElectroStatic Immunity
6kV contact, 8kV air
Transient Immunity
1kV
Operation Temp
-35ºC ~ +55ºC (-31°F ~ +131°F)
Dimensions
160 mm x 70 mm x 45 mm (6.3" x 2.7" x 1.7")
Weight
210gr. (0.45 lb)
European directives
RTTE directive:1999/5/EC
EMC directive: 2004/108/EC
Low Voltage directive: 2006/95/EC
RoHS directive: 2002/95/EC
European standards requirements:
EN300 440-2; EN301 489-1; EN50130-4 +A1 +A2; EN61000-6-3+A11
EN60950-1
EN50131-1 / EN50131-2-4 / EN50130-5
USA & Canada
47CFR part 15, subpart C, section 15.245; 47CFR part 15, subpart B
RSS210; ICES-003
Protection Degree
IEC 60529: IP 65
EN