background image

Fig. 6 

- Detector test

Fig. 5 

- PCB Layout

BLOCK CONNECTOR

LIMITED WARRAN TY:

 

Digital Security Contr ols Ltd, w arr ants that for a  period of 12 m onths  from the  date of pur chase, the  product shall be fr ee of defe cts  in mater ials and wor km anship unde r nor mal use a nd that in

fulfillment of any br each of such  warr anty. D igital Security Contr ols Ltd shall, at it s opt ion, r epair or  re place the  defective equipment u pon ret urns of the e quipm ent to its  repair d epot. This war ranty applies  only to de fects
in  parts and  workmanship and no t to damage  incur red in shippin g or ha ndling, or  damag e due to causes beyond the contr ol  of Digit al Secur ity Con trols  Ltd, such  as lightning, excessive voltage me chan ical sho ck, wate r
damage, or  damage  arising out o f abuse, alter ation or impr oper a pplication  of the equipment.
The  forego ing w arr anty sh all apply only to  the or iginal buyer, and  is and shall be in lieu of  any  and all o ther w arr anties,  whether  expressed or  implied and o f all othe r obligations o r lia bilities on th e part  of Digital Secur ity
Contr ols Ltd . Digital Security Contr ols Ltd  neith er assumes responsib ility for , nor au thorizes an y oth er per so n purpo rting to act on its behalf to modify or t o cha nge this w arr anty, nor  to assume for  it a ny ot her w arr anty  or
liability concer ning this pr oduct.
In no event shall Digita l Secur ity Con trols  Ltd be lia ble f or any direct, indirect or  conseq uential da mages, lo ss of anticip ated pr ofits, loss o f time  or an y oth er losses incurr ed by the buyer  in conne ction with th e purchase,
in stallation  or oper ation or failure of t his pro duct.
Motion det ecto rs can only detect mo tion  within the de signated  are as  as  Sh own in th eir  re spe ctive inst allation instructions. Th ey  can not discr iminate  betwe en intrud ers and  inte nded occupants. Mot ion  detectors do  not
provide vo lumetr ic ar ea prote ction. The y have multiple bea ms of d etection and mo tion can only be detected in  unobstructed area s covered by these beams. They cannot detect motion which occur s beh ind w alls, ceilings,
flo or, closed door s, g lass partitions, g lass doors or  windows. Any
type of  tamper in g whe ther  in tentional or  unintentional such as m asking ,  painting, or  spra ying  of any ma terial on  the lenses, mirr ors,  windows or  any o ther  part  of th e detection system w ill impair its pr oper  oper ation.
Passive  infr ared  motion detectors oper ate by sensing changes in temper atur e. Howe ver  their effectiven ess can be r educed when  the ambient temper atur e rises ne ar or  above body temper ature  or if ther e are intentional
or   u nin ten tion al  so ur ces  of  he at  in  or   n ea r  th e  d et ectio n  a r ea.   So me   of   t hese   h eat   so ur ces  could   be   h ea ter s,  r adia tor s,  sto ves,  bar b equ es,  fir ep laces,   su nligh t,  stea m  vent s,  lig ht in g  and   so   o n.

WARNI NG: Di git al Securit y Co nt rols  Ltd , reco mm end s t hat  th e en tire sys tem  be  com plet ely t ested  o n a reg ula r  basis.  However, d espit e f re qu ent  test ing , an d d ue  to , bu t n ot  lim ited  to , crim inal t am perin g
or elect rical d isru pt ion , it i s po ssible f or t his p rod uct  to  fail t o p erfo rm  as exp ecte d.
Im p ort an t   in f orm a tio n :   Ch an g es  or  mo d if ica ti on s  no t   ex pre ssl y  ap p ro ved   b y  D ig it al   Secu ri ty   Co n tro ls   L td   c ou ld   v oi d  t h e  u se r's  a ut h or it y  t o  op er at e  t hi s  e qu ip m en t.

   2005 Digital Security Controls Ltd
Toronto, Canada

www.dsc.com

TESTING THE DETECTOR

Set the jumpers as follows:

 LED =ON, SHOCK=ON.

1.

 Use the simulator in manual mode to simulate the noise of glass breaking . Check that the yellow  LED is ON. If it does not light, a sensitivity

calibration is necessary. Rotate the "SEN S" potentiometer clockwise to increase the sensitivity, and counterclockwise to decrease it. 

2.

 Use your

hand or a padded object to firmly strike on door or table. If the green LED does not light, adjust the sensitivity as necessary. 

3. 

Use the Simulator

in automatic mode and check that the red LED lights. If the red LED, yellow LED and green LEDS are ON, your detector is w orking properly.

Cutting of glass by a diamond causes only the red LED to light. If the red LED does not light try adjusting the sensitivity until the red LED lights.

FINAL TESTING

Set the jumpers as follows:

 LED =ON, SHOCK=OFF.

*

 To ensure maximum protection against false alarms, activate any device in the area, w hich might automatically activate, like cycle pumps,

generator s,  heating/ai r  conditioni ng  units ,  etc.  If  thes  devi ces  trigger   an  alar m,  mount  the  unit  i n  a  different  location.

*

 Set the jumpers to their normal working position: SHOCK =  ON.

WIRE SIZE REQUIREMENTS

U se #22 AWG (0.5mm) or wires w ith a larger diameter. Use the following table to determine required wire gauge (diameter) and length of the
wire between the detector and the control panel.

TECHNICAL SPECIFICATION

Power Input

9-16VDC

Current

Standby:

 15mA at 12 Vdc

Consumption

Active: 

40mA at 12Vdc

Detection Range

10m (33ft), Max.
Cutting 3m

Mounting

 

Ceiling or Wall

Alarm Output Relay

N.C. 50mA/24Vdc
10 Ohm in line resistor

Tamper Switch

N.C. 50mA/24Vdc with
10Ohm in line resistor

Operating

-20

o

C to 50

o

C

Temperature R ange

(-4

o

F to 122

o

F)

Operating Humidity

95% max relative humidity

Range

non condensing

Storage 

-30

o

C to 70

o

C

Temperature R ange

(-22

o

F to 158

o

F)

RFI Protection

30V/m 10 -1000 MHz

EMI Protection

50,000V electrical
interference from lightning

Dimensions

 

79mm x 48mm x 21mm

Weight

40gr. ( 1.41oz.)

Wire Length     

 m     200     300    400     800

Wire Diameter  

mm    .5      .75      1.0     1.5

Wire Length      

 ft     800   1200  2000   3400

Wire Gauge      

  #      22      20      18       16