DSC HS2016-4 Скачать руководство пользователя страница 2

Table of Contents

1.0 Quick Reference

3

2.0 Understanding Your Keypad

5

2.1 Icon and LED Keypad Symbols

5

2.2 Keypad Models

6

3.0 The PowerSeries Neo Security System

7

3.1 General System Operation

7

3.2 Testing Your System

7

3.3 Monitoring

8

3.4 Maintenance

8

4.0 Setting/Arming the System

9

4.1 Arming the System (Infinite Exit Delay)

9

4.2 Away Arming the System with the Keypad

9

4.3 Exit Delay Time Restart

10

4.4 Alarm Cancel Window

10

4.5 Using 2-way Wireless Keys and Proximity Tags

10

4.5.1 Arming the System with a 2-Way Wireless Key

10

4.5.2 To Arm the System with a 2-way wireless key

11

4.5.3 Arming the System with a Proximity Tag

11

4.6 Disarming/Unsetting the System

11

4.7 To Disarm/Unset the System with a Proximity Tag

12

4.8 Disarming Error

12

5.0 Emergency Keys

13

6.0 Access Code Types

14

6.1 Opening the Access Code Menu

15

6.2 Adding, Changing and Deleting Access Codes

15

6.3 Burglary Verification

15

6.4 Swinger Shutdown

16

6.5 Call Waiting

16

6.6 Fire Alarm Verification

16

6.7 Silence Fire or CO Alarm

16

6.8 System Lockout due to Invalid Attempts

16

6.9 User Labels (LCD keypads only)

16

7.0 Trouble Conditions

18

8.0 Safety Instructions

23

8.1 Regular Maintenance and Troubleshooting

23

8.1.1 Cleaning and Maintenance

23

9.0 Reference Sheets

25

9.1 System Information

25

9.2 Service Contact Information

25

10.0 Access Code and Sensor/Zone information

26

11.0 Locating Detectors and Escape Plan

29

11.1 Smoke Detectors

29

11.2 Fire Escape Planning

30

11.3 Carbon Monoxide Detectors

31

- 2 -

Содержание HS2016-4

Страница 1: ...R code to the right HS2016 HS2016 4 HS2032 HS2064 HS2064 E HS2128 HS2128 E Alarm Panel User Guide WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be care fully read ...

Страница 2: ...ming Unsetting the System 11 4 7 To Disarm Unset the System with a Proximity Tag 12 4 8 Disarming Error 12 5 0 Emergency Keys 13 6 0 Access Code Types 14 6 1 Opening the Access Code Menu 15 6 2 Adding Changing and Deleting Access Codes 15 6 3 Burglary Verification 15 6 4 Swinger Shutdown 16 6 5 Call Waiting 16 6 6 Fire Alarm Verification 16 6 7 Silence Fire or CO Alarm 16 6 8 System Lockout due to...

Страница 3: ... Ready light and the Armed light are both on an Exit Delay is in progress Away Arm Medical Trouble On indicates a system malfunction or tamper Flashing indicates that the keypad has a low battery condition Follow the instructions displayed or enter 2 to view trouble Correcting the trouble turns off the indicator Chime Panic AC Power Indicates AC Power is present The AC Power light will turn off wh...

Страница 4: ...Brightness 6 Master Code 1 2 8 8 Change Contrast 6 Master Code 1 3 8 8 Add Delete User 5 Master Code Access Code 1 7 0 Reset Smoke Detect ors OR 7 2 5 2 View Troubles 2 Access Code 8 15 View Alarms 3 Access Code 5 1 5 Perform System Test 6 Master Code 0 4 4 4 Buzzer Volume 6 Master Code 1 4 8 10 4 ...

Страница 5: ...hours minutes divider and will flash once per second when the local clock is active 3 Clock Digits 3 4 These are the minute digits when the local clock is active The digits 3 and 4 are used to indicate the zone number for open zones or alarm in memory These two digits combined with the clock digit 2 scroll one zone per second from the lowest number to the highest when scrolling through zones 4 1 t...

Страница 6: ...n only be bypassed manually 2 2 Keypad Models Note In the following list if x 9 the system operates in 912 919MHz x 4 the system operates in 433MHz band or x 8 the system operates in 868MHz band Only models operating in 912 919MHz band are UL ULC listed HS2LCD Alphanumeric LCD keypad HS2LCDP Alphanumeric LCD keypad with Prox Tag support HS2ICN Icon keypad HS2ICNP Icon keypad with Prox Tag support ...

Страница 7: ...ide the protected premises close to the entry exit door s The security system has several zones of area protection and each of these zones is connected to one or more sensors motion detectors glassbreak detectors door contacts etc A sensor in alarm is indicated by the corresponding zone lights flashing on an LED keypad or by mes sages on the LCD keypad Note Only the installer or service profession...

Отзывы: