DSC GS3060-RF Скачать руководство пользователя страница 7

3

This equipment GS3060-RF is fixed and shall be installed by Service Persons only (Service Person is
defined as a person having the appropriate technical training and experience necessary to be aware of
hazards to which that person may be exposed in performing a task, and of measures available to
minimize the risks to that person or other persons). It shall be installed and used within an environment
that provides the pollution degree max 2, over voltages category II, in non-hazardous, indoor locations
only. This manual shall be used with the Installation Manual of the relevant alarm control panel. All
instructions specified within that manual must be observed.

Description

This GS3060-RF manages transmissions to a central station and can simulate the landline in the event of
trouble (e.g., landline down) or even substitute the landline completely in areas where the GSM service
is provided and a landline is not available.
The GS3060-RF has the capability of communicating alarm signals via the GPRS data network. This
capability ensures a fast, reliable path to central stations equipped with a Sur-Gard System III, System II
or System I receiver. By connecting a GS3060-RF to a control panel's standard PSTN interface, tele-
phone-based Contact ID signals are decoded and seamlessly routed through the GPRS network to any
of the compatible receiver options.
The performance of the GS3060-RF depends greatly on GSM network coverage. Therefore, it should not
be mounted without first performing placement tests to determine the best location for reception
(minimum of one green LED ON). Optional antenna kits – GS15/25/50-ANT (15ft/4.6m, 25ft/7.6m or
50ft/15.2m) – are available.
The GS3060-RF requires enrollment with CONNECT 24 to operate. Dealer application forms and
additional information on the CONNECT 24 Voice Response Unit (VRU) and web user interface can be
found at www.connect24.com, or at the following telephone numbers:

USA 1-888-251-7458 CANADA 1-888-955-5583

For UL Residential Fire and Burglary installations, the GS3060-RF is listed as a sole means of communi-
cation or as a back up when used in conjunction with a POTS line (dialer). For UL Residential Fire
installations, the GS3060-RF has provisions for 24-hour standby power.
For ULC Residential Fire and Burglary installations the GS3060-RF is listed as a sole means communica-
tion or as a back up when used in conjunction with a POTS line (dialer).

NOTE: With the current limiter active, there is a risk of discharging the GS3060-RF battery when
transmission frequency is high. The back up battery must always be connected to the device
when the current limiter is enabled.

CONNECT 24 Enrollment Information

Only authorized dealers can enroll a GS3060-RF with CONNECT 24. Dealer application forms and
additional information on the CONNECT 24 Voice Response Unit can be found at the CONNECT 24 web
site www.connect24.com. Please contact CONNECT 24 at the number below for assistance:

USA 1-888-251-7458 CANADA 1-888-955-5583
NOTE: Steps 1 and 2 should be completed before turning on the GS3060-RF unit.
NOTE: Before inserting or removing the SIM card, please ensure the unit is turned off.
STEP 1 - Activate Your SIM Card

Your SIM card must be activated with Connect 24 prior to use. Please call the Voice Response Unit (VRU)
at least 24 hrs prior to installation at 1-866-910-3865.

STEP 2 - Initialize the GS3060-RF with Connect 24

Call the VRU at the toll-free number. Follow the voice prompts and enter your profile number, installer
ID number, installer PIN number and central station number. Ensure that all information is available and
at hand before calling the VRU. This information can be found in your VRU Enrollment Package.

STEP 3 - Determine the Best Location (SIM must be activated for this step)

1. Unscrew the four screws securing the front panel to the cabinet. Remove the front panel.
2. Fit the GSM antenna [2]. Ensure the GSM antenna mounting hardware is fastened securely [3].
3. Install the circuit board:

• From behind the cabinet, insert a standoff (supplied with hardware pack) into each of 4 mounting

holes and press into position.

• Press the circuit board onto the standoffs.

INSTALLING THE GS3060

Содержание GS3060-RF

Страница 1: ...E INSTALLATION MANUAL WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manu facturer The entire manu...

Страница 2: ......

Страница 3: ...nd on terminal connections loosening of terminal connections damage of conductor insulation WARNING Never install this equipment during a lightning storm Instruct the end user to Not attempt to servic...

Страница 4: ...nterrupted service Equipment Maintenance Facility If trouble is experienced with this equipment for repair or warranty information please contact the facility indicated below If the equipment is causi...

Страница 5: ...ers Technical Specifications The input voltage to the GS3060 RF is drawn from the power adaptor model DSC ADP1310 NAU for USA and model DSC ADP1310 NA for Canada NOTE The power supply must be Class II...

Страница 6: ...PGM2 19 20 DC IN 11 AUX 16 Z2 17 Z3 15 Z1 14 COM 10 PGM4 7 PGM1 6 COM 4 T1 5 R1 2 TIP 3 RNG 1 18 Z4 JP3 JP3 tie wrap OFF ON All circuits are classified for UL installations as Power Limited Class II P...

Страница 7: ...Residential Fire and Burglary installations the GS3060 RF is listed as a sole means of communi cation or as a back up when used in conjunction with a POTS line dialer For UL Residential Fire installat...

Страница 8: ...This terminal is connected internally to Power Ground PGM1 7 PGM2 8 PGM3 9 PGM4 10 Programmable Open collector Outputs These outputs can be activated by programmed events Refer to Activating the Outpu...

Страница 9: ...Trouble condition exists This LED switches on when the interface switches to the GSM Network due to a Landline trouble condition This LED flashes slowly in the event of an incoming or outgoing voice...

Страница 10: ...s the alarm and sends a command to the GS3060 RF to generate the corresponding 1400Hz Kiss off signal for a minimum of 800msec After the GS3060 RF generates a Kiss off signal it sends the next alarm o...

Страница 11: ...IT ACTIVATION R552 RADIO XMITTER DISABLED 000 GSM INTERNAL BUFFER FULL E624 EVENT LOG OVERFLOW 000 FTC RESTORAL R354 FAILURE TO COMMUNICATE 000 Swinger Shutdown Swinger Shutdown is followed by a PSTN...

Страница 12: ...The GS3060 will not show signal strength until the SIM is active Panel Programming the control panel should be programmed to communicate Contact ID exactly the same way it would be programmed to commu...

Страница 13: ...rated at 13 8VDC 120mA minimum Ensure the GS3060 jumper J3 is OFF Two Flashes SIM Radio Trouble Ensure the SIM Card is inserted correctly and firmly Ensure the antenna cable is plugged securely into t...

Страница 14: ...rt in this guide No signals are received at the central station but no trouble condition is displayed Ensure the control panel has a central station phone number programmed Ensure the control panel ha...

Страница 15: ...r it typically takes less than an hour for the SIM card to be activated Checking SIM status Go to www connect24 com and login A search can be performed for a specific account and its current status SI...

Страница 16: ...quired for normal long term operation Telephone Line Connection Supervision Relay RM1 UL Installations RM1C ULC Installations WARNING Incorrect connections may result in PTC failure or improper operat...

Страница 17: ...2 COM 20 Z1 12 AUX PGM 3 PGM 1 13 PGM 4 COM TAMPER GS3060 PGM 3 DC IN KSAD1380100W1US Power Adaptor NOTES 1 Program the Zone Point as Supervisory type with keypad only annunciation when in Alarm Do NO...

Страница 18: ...agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DS...

Страница 19: ...s to adversely affect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement under warranty will be credited or replaced at DS...

Страница 20: ...LYHO HQIRUFH LWV LQWHOOHFWXDO SURSHUW ULJKWV WR WKH IXOOHVW H WHQW RI WKH ODZ LQFOXGLQJ SXUVXLW RI FULPLQDO SURVHFXWLRQ ZKHUHYHU QHFHVVDU OO WUDGHPDUNV QRW RZQHG E 7 FR QWHUQDWLRQDO WG DUH WKH SURSHUW...

Отзывы: