background image

3G4010CF Wiring Diagrams

Figure 2: 3G4010CF Wiring Diagram

5

4

1

2

3

6

7

8

9

1

0

1

1

1

4

1

5

1

6

1

7

LE

LI

O1

O2

O3

O4

+OC

1

3

1

2

AS

L1

L2

L3

L4

1K

5

T

I

P

R

I

N

G

3G4010CF

3

2

DC IN

A

U

X

2

3

1

COM

4

1

COM

T1

R1

TIP

RING

4

PGM

ZONE

+

-

R

J-

4

5

E

arth-ground

G

round w

ir

fr

om

bui

ldi

ng elec

tr

ic

al 

ins

tal

lati

on

}

G

R

O

U

N

D

C

O

N

N

E

C

TIO

N

T

ighten nut to break

 pai

nt &

m

ak

e good c

onnec

tion to 

the c

abi

net.

N

ut

N

ut

B

ol

t

Loc

k w

as

her

Loc

k w

as

her

S

tar w

as

her

C

abi

net

A

larm

 C

ontrol

 P

anel

 w

ith

D

ial

ler Interfac

e

(S

upports

 C

ontac

t ID

 and 

S

IA

 form

ats

)

C

onnec

to P

ow

er 

S

uppl

Ter

m

inal

+12/

C

O

M

Tel

ephone Li

ne

C

onnec

tion

S

uperv

is

ion

R

el

ay

R

M

2-U

L Ins

tal

lati

ons

C

onnec

t rel

ay

 c

ontac

ts

 to

a z

one i

nput on the al

arm

control

 panel

 for 3G

4010C

F

troubl

es

 s

uperv

is

ion 

(24hr-ty

pe z

one)

O

pti

onal

 

us

e of P

G

M

output (S

ee

P

rogram

m

ing)

W

A

RNI

NG

!

HIGH 

V

OL

T

A

GE. DISCONNECT 

A

C

PO

WER & 

TELEPHONE LINES

PRIOR 

T

O SER

VICING

W

A

R

N

IN

G

: Inc

orrec

t c

onnec

tions

 m

ay

 res

ul

t i

n P

TC

 fai

lure or i

m

proper operati

on. Ins

pec

t w

iri

ng

 an

en

sure 

con

ne

ct

ion

are 

corre

ct

 be

fore 

turni

ng

 on

.

A

ll c

irc

ui

ts

 are c

las

si

fied for U

L i

ns

tal

lati

ons

 as

 P

ow

er Li

m

ited/C

las

s II P

ow

er Li

m

ited ex

cept 

for 

the

 ba

tt

ery

 lea

ds

 w

hi

ch 

are

 no

P

ow

e

Li

m

ited

D

no

rou

te 

an

w

iri

ng

 ov

e

ci

rc

ui

bo

ards

M

ai

nt

ai

at

 lea

st

 1” 

(25.4m

m

) s

eparati

on. 

A

 m

ini

m

u

m

 1/4” (6.4m

m

) s

eparati

on m

us

t be m

ai

ntai

ned at al

l poi

nts

 betw

een P

ow

er 

Li

m

ited 

w

iri

ng 

and al

l ot

her 

N

on-P

ow

er 

Li

m

ited 

w

iri

ng.

  

R

out

e w

ires

 as

 indi

cated 

in t

he 

di

agram.

P

hone l

ine c

onnec

tion i

s requi

red onl

y for bac

k-up c

onfi

gurati

o

ns

. In s

tand-al

one appl

ic

ati

ons

no 

other 

comm

uni

cati

on 

tec

hnol

o

gy

 is

 requi

red 

for

 Fi

re 

A

lar

m

 M

oni

tor

ing.

 R

efer

 t

o Fi

g. 

4 f

or

 w

iri

ng 

det

ai

ls

S

ugges

ted c

om

pati

bl

e D

A

C

T

 m

odel

s for us

e w

ith 3G

4010C

F are D

S

C

 m

odel

s: P

C

4020C

F w

ith 

P

C

47

0I

 I

nt

erf

ac

e

 or 

P

C

50

20

C

F

 w

ith 

P

C

57

00

 I

nt

erf

ac

e

 

(U

se N

o. 26 

A

W

G

 w

ires

 for the  c

onnec

tion to P

S

TN

)

P

hone l

ine c

onnec

tion i

s requi

red onl

y for bac

k-up 

confi

gurati

ons

. In s

tand-al

one appl

ic

ati

ons

, no other 

com

m

uni

cati

on tec

hnol

ogy

 is

 requi

red for Fi

re 

A

larm

 

M

oni

tori

ng. R

efer to Fi

g. 4 for w

iri

ng detai

ls

S

ugges

ted c

om

pati

bl

e D

A

C

T

 m

odel

s for us

e w

ith 

3G

4010C

F are D

S

C

 m

odel

s: P

C

4020C

F w

ith 

P

C

470I Interfac

e or P

C

5020C

F w

ith P

C

5700 Interfac

e.

For 

U

LC

 Fi

re 

M

oni

tori

ng 

ins

tal

lati

ons

 fi

re 

al

arm

 s

ignal

shal

be 

sent

 s

im

ul

tane

-

ous

ly

 ov

er 

P

O

TS

 l

ine 

(us

ing 

the 

di

al

ler) 

and 

ov

er 

the 

w

irel

es

net

w

or

(us

ing 

3G

4010C

F). 

C

onnec

al

arm

 output 

from

 c

ontrol

 panel

 (P

G

M

to 

the 

input 

on 

the 

3G

4010C

F that i

s program

m

ed as

 a Fi

re 

A

larm

 Input

.

E

xam

pl

es

 of C

ontrol

 U

ni

ts

/S

ubs

cri

bers

 U

ni

ts

 or P

ow

er 

S

uppl

ies

 

com

pati

bl

e m

odel

s:  D

S

C

 P

C

1864, P

C

1832, P

C

1616, 

P

C

5204,

 etc

.

Thi

s c

onnec

tion 

is

 nec

es

sary

Inputs

 t

o be 

connec

ted 

to dr

cont

ac

out

put

from 

al

ar

m

 c

ont

rol

 panel

 w

ith 5.6K

 E

O

res

is

tors

Thes

inputs

 ar

e t

ypi

cal

ly

 us

ed t

o i

nter

fac

w

ith f

ire al

ar

m

 

panel

that

 do 

not

 hav

e a di

al

er

 inter

fac

and us

the 

fire al

ar

m

fire s

uper

vi

sor

or 

fire t

roubl

e out

put

 rel

ay

 c

ont

ac

ts

 t

o s

end t

he 

ev

ents

 t

o t

he 

comm

uni

cator

.

N

O

TE

For 

Zone 

Inputs

/P

G

M

 out

put

s,

 D

C

 I

N

, A

U

X

 w

iri

ng,

 us

si

ze N

o. 

18-22 

A

W

G

 c

on

du

ct

ors

D

no

us

e

 s

hi

el

de

w

ires

.

The 3G

4010C

F s

hal

l be i

ns

tal

led i

n ac

cordanc

e w

ith the

 f

ol

low

ing,

 as

 appl

ic

abl

e: 

N

FP

A

 7

0,

 "N

a

tio

na

l E

le

ct

ri

ca

l C

o

de

.",

 N

F

P

A

 7

2,

 "N

a

tio

na

l F

ire

 A

la

rm

 C

o

de

.",

 N

a

tio

na

l B

u

ild

in

C

o

de

 (N

B

C

);

 C

S

A

 C

2

2.

1

 - 

C

anadi

an E

lec

tri

cal

 C

ode, P

art 1; S

ec

tion 32, C

A

N

/U

LC

 S

561 - 

S

tandard f

or

 t

he 

Ins

tal

lati

on 

and S

er

vi

ces

 f

or

 Fi

re S

ignal

 R

ec

ei

vi

ng 

C

ent

re and S

ys

tems

C

A

N

/U

LC

-S

302 - 

S

tandard f

or

 I

ns

tal

lati

on 

and 

C

las

si

fic

ati

on of B

urgl

ar 

A

larm

 S

ys

tem

s for Fi

nanc

ial

 and 

C

omm

er

ci

al

 P

remi

ses

S

afes

 and V

a

ul

ts

C

A

N

/U

L

C

 S

3

01

 - 

S

ta

nd

ard

 f

o

th

S

ig

na

l R

e

cei

vi

n

C

e

nt

re

 B

u

rg

la

A

la

rm

 S

ys

te

m

a

nd

 O

p

era

tio

ns

L

oc

a

A

uthori

ties

 H

av

ing J

uri

sdi

cti

on (A

H

J) and M

anufac

turer'

s I

ns

tal

lati

on 

Ins

truc

tions

18

Содержание 3G4010CF

Страница 1: ...ercial RF Communicator 3G HSPA Network Signaling Devices INSTALLATION MANUAL V4 0 Warning This manual contains informationon limitations regarding product use andfunction and inform ationonthelimitati...

Страница 2: ...Principles 10 Simulated Landline Mode 10 Panel Transmission Monitoring PTM 10 Cellular Communications Sequence 11 Inputs 11 Outputs 11 Activating the Outputs 11 Reporting Codes 12 Swinger Shutdown 12...

Страница 3: ...uper vision window for reporting single technology communicator trouble shall be set to five minutes However the product can be installed in accordance with the requirements ofNFPA72 2013 edition whic...

Страница 4: ...ng voltage 13 75Vdc Battery charge current 700mA maximum NOTE Battery mustbe replaced every 3 5 years Operating frequency 2G GSM GPRS EDGE 850 1900MHz Operating frequency 3G UMTS HSPA 850 1900MHz Ante...

Страница 5: ...3G Antenna 2 Metal Casing 3 Antenna Mounting Hardware 4 Antenna Connector 5 Anchor Screw Holes 3mm 6 SIM Card Holder 7 3G HSPA Radio Module 8 Status LEDs See page 1 Part 9 PC Link Connector 10 Tamper...

Страница 6: ...eatsent The 3G4010CF is designed to work with the ContactID com munication formatas described in SIADC 05 Standard or the 300 baud SIA communication formatas described in SIA DC 03 standard Every 24 h...

Страница 7: ...ll move to Step 3 and scan for carriers with sufficientsignal strength and attach to the carrier Ifthe 3G4010CF is connected to a carrier with sufficientsignal strength min imum ofbottom signal streng...

Страница 8: ...reen Top Yellow Green Bottom ON ON ON FLASHING and turn on solid when itreceives a communication back from the central station Red Blue Yellow Green Top Yellow Green Bottom ON ON ON ON Ifat leastone o...

Страница 9: ...iate an AC trouble by flashing the RED status LED 9 times and will delay the AC loss eventtransmission by one hour LBT Battery Trouble This open collector outputactivates when a Battery Trouble condit...

Страница 10: ...ndline has been restored the 3G4010CF switches the connected device back to the landline OR l Ifthe landline is still down the 3G4010CF continues the simulation until the landline is restored The 3G40...

Страница 11: ...ContactID or SIA formatwith Inputs 1 4 reporting as 991 to 994 respectively Defaultsettings are INPUT 1 AC LOSS INPUT 3 FIRE ALARM INPUT 2 FIRE SUPERVISORY INPUT 4 SYSTEM TROUBLE Inputs can be config...

Страница 12: ...oes notsupportremote programming local hardware defaultrequired Upon activation through Con nect24 the productwill operate as described in this manual Swinger Shutdown To prevent runaway signals to th...

Страница 13: ...on offtogether indicates the radio is notready This LED sequence will display until the low battery voltage is restored and the radio is enabled again SMS Command and Control NOTE For UL ULC installa...

Страница 14: ...uage Command Label shallnot be case sensitive English Disarm French Desarmement Spanish Desarmado l Activate PGM Language Command Label shallnot be case sensitive English Activate French Activation Sp...

Страница 15: ...gnal Strength 14 l Unitcan be installed in the currentmounting location Top LED FLASHING with bottom LED ON Excellent Signal Strength 11 13 l Unitcan be installed in the currentmounting location Botto...

Страница 16: ...e antenna cable is plugged securely into the radio connector l Ifthe SIM is active connecta battery to the unitand testvarious locations for good excellentsignal strength l Connectan antenna extension...

Страница 17: ...connector Gently turn the screwdriver away to pop outthe connector from the modem l To install the antenna firmly push the connector into the modem until it snaps into place Enrolling a 3G4010CF l Th...

Страница 18: ...0CF with PC5700 Interface Use No 26 AWG wires for the connection to PSTN Phone line connection is required only for back up configurations In stand alone applications no other communication technology...

Страница 19: ...gered when the 3G4010CF is locally or remotely restar ted Please contactpanel vendor for details on how to resetthe control panel PGM Figure 4 Power Supply Wiring Diagram PS4085 12V COM ACT LBT TEST B...

Страница 20: ...6 19 Z4 Z3 Z2 COM 20 Z1 AUX PGM 3 PGM 1 PGM 4 COM 3G4010CF PGM 3 DC IN DSC Supervision Relay See Note Power Supply Provides power to the 3G4010CF Module NOTES 1 Program the zone pointas Supervisory ty...

Страница 21: ...nycopiesof the SOFTWARE PRODUCT are owned by DSC or its suppliers You may not copythe printed materialsaccompanying the SOFTWAREPRODUCT Alltitle and intellectualpropertyrightsin and to the contentwhic...

Страница 22: ...ission public service commission orcorporation commission for information Alarm dialling equipment must be able to seize the telephone line and place a call in an emergency situation Itmustbe able to...

Страница 23: ...acilitiesorservices down time pur chaser stime the claimsof third parties including customers and injury to prop erty The laws of some jurisdictions limit or do not allow the disclaimer of consequenti...

Страница 24: ...o willaggressively enforce its intellectualproperty rightsto the fullestextent ofthe law including pursuitofcriminal prosecution wherever necessary All trademarksnotowned byTyco are the propertyofthei...

Отзывы: