DS652LR5 User Manual 36
Enclosures
For outdoor applications, an external enclosure is required to protect the display. When designing the
enclosure, the temperature inside the enclosure must be maintained between 0°C-40°C (32° F–104°F).
Always consult your local enclosure builder or integrator for additional recommendations.
Enclosure
Using a Cooling & Heater Solution
To maintain the proper operating temperature inside the enclosure, you may consider using a cooling
and heater solution such as an air conditioner, heat exchanger, or combined cooler and heater
depending on the external environment. (See below examples)
•
You can also employ an air flow circulation system and air curtain* between the front panel and
the enclosure.
•
An enclosure rated IP65 or better is recommended.
•
Use an air filter to prevent dust. (At air inlet and outlet)
•
For preventing from rust of lead frame in circuit board, operate the heater if relative humidity is too
high.
0°C - 40°C