DryMax MHT100A-1 Скачать руководство пользователя страница 8

8

START UP

The following procedure must be followed to start your air dryer. Failure to follow this start up 

procedure will void your warranty. If problems occur during start up, contact your distributor.

1.  Turn off the On/Off switch.

2.  Verify the main electrical supply voltage matches the voltage specified on the data label.

3.  Check the proper connection and support of the compressed air lines to the dryer: check dryer 

bypass and isolation valve system.

4.  Confirm that the inlet and ambient air temperature, pressure and flow to the dryer meet the 

specified requirements.

5.  Confirm that the condensate drain lines from the separator are properly piped to an environ-

mentally approved disposal system

INITIAL RUN PROCEDURE 

After start up and checks are complete and after the main electrical power to the dryer has been 

turned on for at least 6 hours (only for 460-3-60 & 230-3-60 dryers), follow the procedure below to 

put the dryer in operation:

1.  Turn ON the dryer ON/OFF switch.

2.  Let the dryer run for 15 minutes. (For 460-3-60 & 230-3-60 dryers After 15 seconds observe the 

refrigerant suction pressure gage. It should start to pull down immediately. (This will indicate 

that L1,L2,L3 is connected for proper rotation. If the pressure does not pull down switch 2 of 

the L1,L2,L3 leads.) 

3.  Check the refrigerant suction pressure gage:  

Should read: On R134a dryers. (28 psig to 34 psig)  

Only: MHT75, MHT100,MHT130

4.  Check the 

DEWPOINT TEMP INDICATOR

. After about 15 minutes This should read  

35 F to 39 F.

5.  Verify that the condenser fan motor is operating. The fan will cycle on and off.

6.  Confirm that condensate is discharging from the condensate drain. This may take 30 -60  

minutes.

Содержание MHT100A-1

Страница 1: ...nel Road Mississauga On L4Z 2C2 Phone 1 905 897 8485 Toll Free 1 888 486 4445 e mail sales drymaxairdryers ca ww www drymaxairdryers ca Visit our website www drymaxairdryers ca For brocheurs manuals drawings technical data ...

Страница 2: ...DRYMAX DRYMAX DRYMAX DRYMAX 905 897 8485 ...

Страница 3: ...of the compressed air stream Warm saturated air enters the air to air heat exchanger at the dryer inlet 1 In the air to air heat exchanger the inlet air is pre cooled by the outgoing cold air The pre cooled air then enters the air to refrigerant heat exchanger 3 were it is cooled to its lowest point by the refrigeration in the evaporator As the air is cooled moisture in the air changes from a vapo...

Страница 4: ...om the compressor Do not use the inlet and outlet of the air dryer to support the weight of the air piping 5 3 valve bypass and Isolation valves should be installed on the air dryer outlet and inlet ports to allow for bypassing depressurizing and proper maintenance and servicing of the air dryer 6 Condensate Drains Condensate drains must be properly piped from the dryer to prevent moisture re entr...

Страница 5: ......

Страница 6: ...del and serial number and important technical data Before installing the dryer check all the information on the data label for the correct model and voltage If the model number and voltage are incorrect do no install the dryer Do not put power to the dryer Call your local distributor DATA LABEL Model MHT100A 1 Serial Date of MFG Voltage 115v 1ph 60hz Voltage Range 103 5 126 5 RLA 13 LRA 69 Min Cir...

Страница 7: ......

Страница 8: ...art up and checks are complete and after the main electrical power to the dryer has been turned on for at least 6 hours only for 460 3 60 230 3 60 dryers follow the procedure below to put the dryer in operation 1 Turn ON the dryer ON OFF switch 2 Let the dryer run for 15 minutes For 460 3 60 230 3 60 dryers After 15 seconds observe the refrigerant suction pressure gage It should start to pull down...

Страница 9: ...the air Push the TEST button to manually open the drain valve HOW TO MAKE MINOR REFRIGERANT SUCTION PRESSURE ADJUSTMENTS 1 Keep dryer running under a no load by turning off or bypassing the compressed air 2 Remove dryer top and locate the Hot Gas Bypass Valve 3 Remove cap on Hot Gas Bypass Valve and using an allen wrench turn valve counter clockwise to decrease the suction pressure and clockwise t...

Страница 10: ...verify drain operation Check the open time Check the closed time If drain is not opening the drain should be dis assembled cleaned and checked for defects DANGER This should only be done by a qualified service technician Close the isolation valve before the drain Remove the power unit and timer Remove solenoid coil Dis assemble valve and check for debris and or defective spring or valve parts Clea...

Страница 11: ...11 DATE CLEAN SERVICE AMBIENT SUCTION DISCHARGE AIR CONDENSER DRAIN TEMP PRESSURE PRESSURE PRESSURE MAINTENANCE LOG ...

Страница 12: ...Province of Ontario DRYMAX DRYMAX DRYMAX DRYMAX DRYMAX INC SERVICE DEPARTMENT 905 897 8485 ...

Отзывы: