Dry-Matic DM01B Скачать руководство пользователя страница 7

DM01B & DM07B  - Operating Instructions, Installation Instructions, Wiring diagrams  June 2017

7

Installation Procedure

Based on the above criteria:

1. Fit Diffuser 

 Before cutting hole for diffuser, check that it will clear ceiling 

joists and roof structure.  Use circle template to cut correct sized hole in the 

ceiling.  Attach duct to grille, taping the centre duct sleeve to the grille spigot 

then separately taping the insulation/outer to the spigot.  Feed ducting 

through the hole and clip diffuser in place using the spring clips.  Ensure 

grille has a minimum gap of 16mm between inner disk and outer collar.  

2. Assembly of Unit 

 It is suggested that this is done in a clear space on the 

floor.

FAN:  Mount fan brackets / hanging lugs to side of fan.

HEATER (on heated models):  Fit to inlet of fan using 4 screws provided 

(note airflow direction for fan is shown by an arrow on the terminal 

cover).  Ensure airflow direction arrow on heater is the same as 

direction on fan, ensure heater is mounted so marked top is installed 

upright.

FILTER BOX:  Fit to heater (on heated models), or fit to the fan using the 

supplied collar, so that the hanging bracket is on the heater/fan inlet 

side.  Ensure airflow direction arrow on filter is same as fan.

PRE FILTER:   Fit white pre filter bag to inlet of filter box.

3. Pre Wiring 

  Using supplied flying leads, connect attic control unit to fan 

and heater (on heated models).  Check wiring diagrams on components 

carefully. For 3 speed fans, wire to the high speed (black) wire as indicated 

on the fan junction box. 

4. Installing in Attic 

  Lift assembled unit into attic space.  Fit supplied 

cup hooks (x2) to roof structure.  Clip supplied bungies (x3) to the three 

mounting points on assembled unit.  Lift unit into position and hook other 

end of bungy cords over cup hooks.  Attach duct to fan outlet, taping core 

and insulation/outer as before.  Adjust length of bungies so unit is level and 

tighten cable ties to lock unit into position.  

5. Mount & Set Attic Controller 

 Mount vertically, can be fixed to the timber 

framing. For DM01B & DM07B models, set the top Summer Off” thermostat 

to 27°C, and the lower “Hi/Lo”(for DM01B) or “Heater” (for DM07B) 

thermostat to 15°C.  

6. Power Supply  

  Connect a power supply to attic controller isolating switch 

(by registered electrician).

7. Check Operation

   check the unit is operating correctly.

Dry-Matic Installation Instructions 

(continued)

Содержание DM01B

Страница 1: ...uctions Installation Instructions Wiring diagrams June 2017 1 Dry Matic DM01B DM07B with Attic Controller User Operating Instructions p2 3 Installation Schematic p4 5 Installation Instructions p4 7 Wa...

Страница 2: ...provides the benefits of Virtually eliminating condensation on windows and cold surfaces by forcing out moist stale air and replacing with relatively dry air Reducing airborne concentrations of irrit...

Страница 3: ...gns of dust and dirt it can be vacuumed clean or replaced It is recommended to clean or replace every second year You may prefer to get a professional to climb into the attic space to access the filte...

Страница 4: ...DMM01B DM07B Operating Instructions Installation Instructions Wiring diagrams June 2017 4 Smooth Air Products Ltd Dry Matic Installat...

Страница 5: ...DM01B DM07B Operating Instructions Installation Instructions Wiring diagrams June 2017 5 nstallation Schematic See next page for installation instructions...

Страница 6: ...Fan Heater for DM07B and Filter box It is important to install the Unit so that it is as high as possible in the roof space this is to maximize the benefit of any thermal gain It also keeps the fan in...

Страница 7: ...using the supplied collar so that the hanging bracket is on the heater fan inlet side Ensure airflow direction arrow on filter is same as fan PRE FILTER Fit white pre filter bag to inlet of filter box...

Страница 8: ...ost of the goods as details above Any vent or duct filling a hole or cavity in the ceiling that was installed as part of the installation of the goods will be left in place The money back guarantee do...