Congratulations on your purchase of the 
Atlantic LGR dehumidifier. Please 
carefully read the operation and 
maintenance instructions prior to operating 
the unit.  Following these instructions will 
ensure proper operation, transportation and 
storage of the Atlantic LGR.  This will 
maximize the performance and minimize 
occurrences of misuse that may result in 
unnecessary service and repairs and 
shorten the operating life of the unit.  

SAFETY INFORMATION 

Caution!

  

Unit operates on alternating current: 

110/120 volt, 60 Hz 

Or 230 volt, 50 Hz

  

Do not operate your Atlantic LGR 
Dehumidifier with a cut or frayed power 
cord.  Do not unplug your dehumidifier 
by pulling on its cord.  Grasp the plug 
firmly and pull it out of the wall socket.  
The plug has a safety ground pin 
installed that must not be removed.  If 
the pin is damaged or missing, have the 
power cord replaced at once.  Visually 
inspect the power cord before each use.  
Ignoring these safety precautions may 
result in a fire or an electric shock.  

Never operate electrical equipment in 
standing water.  There is a shock hazard.  

Never drop the unit.  Sudden and severe 
impact may result in damage to internal 
components. 

Your Atlantic LGR Dehumidifier should 
not be operated with the unit’s outer 
cover removed.  Personal injury may 
result. 

Drapes or other loose fabrics can be 
drawn against the unit restricting its 
airflow.  This condition may cause the 
unit to overheat.  Assure that there is 
sufficient space between the back of the 
unit and these fabrics to avoid this 
condition. 

Save the shipping carton in case your 
Atlantic LGR Dehumidifier must be 
returned for repair.  Discard the plastic 
bag to prevent children from using it as a 
toy.  Also, children should not be 
allowed to play on or near a running 
dehumidifier. 

Never operate your Atlantic LGR 
Dehumidifier outside when it is raining 
and never store your dehumidifier 
outside. 

This unit should never be serviced or 
cleaned while it is plugged into a live 
electrical power source. 

Warning! 

Ignoring these safety precautions may 

result in serious personal injury.

 

OPERATION 

Inspection of unit:

  Upon delivery of your 

Atlantic LGR dehumidifier, inspect the 
packaging for signs of damage.  If you 
suspect any concealed damage, it is critical 
that the damage be identified and noted 
before you sign for the delivery.  If this 
procedure is followed the shipping claim is 
between the freight company and the 
company that hired the freight company to 
deliver your unit.  After the delivery 
receipt is signed, the claim must be filed 
by your company within 7 days.   

Transportation of unit:

  The Atlantic 

LGR dehumidifier MUST be transported 
in the vertical, operating position.  The 
unit may be placed in a horizontal position 
on its back for loading and unloading 
purposes only.  Transporting the unit in 
this position puts undue stress on the 
refrigeration components and tubing and 
can also cause significant damage to these 
parts.  If the unit has been in a horizontal 
position prior to use, place the unit upright 
and wait for 60 minutes before starting the 
unit.    

Содержание ATLANTIC LGR

Страница 1: ...mation Please read before using the dehumidifier and save for future reference Purchase Date ______________________________Serial No __________________________________ 313 North Oak Street Burlington...

Страница 2: ...e Keep the unit plugged in and the discharge hose in a receptacle Allow the unit to thaw thoroughly until the side of the unit is no longer cold to touch Press the purge switch to completely empty the...

Страница 3: ...ts airflow This condition may cause the unit to overheat Assure that there is sufficient space between the back of the unit and these fabrics to avoid this condition Save the shipping carton in case y...

Страница 4: ...l cause damage to the compressor A false low charge may be sensed by the control if the refrigerant is cold The automatic restart will switch the unit back on if the pressure in the system increases I...

Страница 5: ...rough each coil After removing the dry particle contamination a wet cleaning process may be used Caution Do not use a hose to flush the coils and do not permit water to leak into the electrical compar...

Страница 6: ...ich allows access to the cooling coil surfaces Rugged ABS Skid Panel Panel makes loading and unloading simple and protects the unit from scratches and abrasions Control Panel The control panel plus th...

Страница 7: ...T RD 00E NNHN0279 Relay 6 240 VAC 50 60 Hz RD 00E NNAN0255 Evaporator Coil RD 02M N2AN0246 Condensor Coil RD 02M N2AN0245 Condensate Pump RD 00M PNA10241 ICM Defrost Control RD 00E N6NN0236 ICM Defros...

Страница 8: ......

Страница 9: ...and can be refused for credit or return 1 Normal wear and tear 2 Improper packaging by customer causing freight damage 3 Failure to provide a suitable operating environment 4 Use of the product for pu...

Страница 10: ...of nature or any other cause beyond Dry Air Technology s reasonable control End User Responsibilities Warranty service must be performed by a firm or individual authorized by Dry Air Technology If th...

Отзывы: