When checking/adjusting the burner
pressure, the appliance should be in operation
for at least 10 min.

!Tip

The adjusting screw is located behind the
cover screw.

4.1 Add G31 type plate

Paste the G31 type plate over the G20 type plate, which
is located on the bottom front plate of the casing
(see figure 3).

5. Final check

In order to check whether the appliance is working
properly and safely, you must perform the following
checks before the appliance is used.

5.1. Gastightness

Caution

All connections must be gastight.

!Caution

The gas control valve can be subjected to a
maximum pressure of 50 mbar.

• Check the connections for gastightness.
• Make the connections gastight, if necessary.

5.2. Gas pressure / supply-pressure

The supply-pressure in house installations should be
checked, as they can vary.

Caution

-After conversion to propane, the burner

pressure must be checked and adjusted,
if necessary;

- After maintenance work the burner

pressure must be checked, irrespective
of whether you are using natural gas or
propane, and adjusted if necessary.

Proceed as follows; see fig. 2:

• Check the supply-pressure.
• Contact the gas company if the supply-pressure is not

correct.

!Caution

When checking/adjusting the burner
pressure, the appliance should be in operation
for at least 10 min.

• Adjust the burner pressure, if necessary.

!Tip

The adjusting screw is located behind the
cover screw.