Use a parker to fix the clip binding to the pipe on locations that are unreachable after installation;
➠
Apply sufficient clamps, so that the weight of the pipes does not only rest on the appliance;
➠
Determine the remaining length of the roof duct;
➠
Make sure the roof duct has the right dimensions.
!Caution
Make sure that the right insertion length is maintained.
➠
Connect the roof duct to the concentric pipes.
!Caution
- Make sure that the universal tile fits well with the surrounding tiles;
- Make sure that the adhesive plate fits well onto the flat roof.
6.5.4 Connection of existing chimney flue
It is possible to connect the appliance to an existing channel.
A flexible SS pipe is placed in the chimney for discharging flue gases. The surrounding space is used to supply
combustion air.
The following requirements apply when connecting to an existing chimney flue:
- only allowed when used in combination with the special DRU chimney installation set.
The installation regulation is also supplied;
- the dimensions should be at least 150 x 150 mm;
- the vertical length has a maximum of 12 meters;
- the horizontal length has a maximum of 3 meters;
- the existing chimney flue has to be clean;
- the existing chimney flue has to be closed.
For adjusting the appliance, the same conditions/instructions apply as for the concentric system described above.
6.6 Connecting gas
Use the following procedure when connecting the gas, see section 6.3 Gas connection:
➠
If necessary, blow through the gas pipe;
➠
Connect the gas pipe with gas tap to the gas control block.
!Caution
- You can find the gas control block behind the door in the space at the bottom of the appliance;
- Do not turn the gas tap when connecting the gas pipe.
➠
Bleed the gas pipe.
6.7 Setting the appliance
The appliance has to be set in such a way that is works correctly in combination with the discharge system.
For that purpose it is possible to install a baffle. For the conditions, see section 6.5.2.1, for application with wall duct
and section 6.5.3.1, Table 2, for application with roof duct.
6.7.1 Baffle (R)
!Caution
The restrictor slide should be placed in the correct manner. Therefore, accurately observe the instructions
The baffle (R) is supplied separately.
Follow the procedure below when placing the baffle:
➠
Remove the front pane as indicated in section 6.9.1;
➠
Place the baffle (
see Appendix 4,
Fig. 4
);
➠
Use the template supplied to set the distance of the restriction (
see Appendix 4,
Fig. 5
) as follows:
- A distance of 33 mm means that the baffle is closed to a maximum level;
- A distance of 38, 43, 48 and 60 mm is set by means of a template.
➠
Fix the baffle by using the socket cap screw (S).
6.8 Placing the wood set
The appliance is supplied with a wood set.
Caution
Strictly observe the following instructions to prevent unsafe situations:
- only ever use the supplied wood set;
- place the wood set exactly as described;
- make sure the pilot burner and the space around it are kept free from objects (
see Appendix 4,
Fig. 6
);
- make sure that the slot between the burner tray and the tray surrounding the burner is kept free from objects.
- make sure that the vermiculite’s fine dust does not get on the burners.
uk
Содержание G31 Propane
Страница 19: ...19 E n g l i s h trio instruction for installation Fig 7 Fig 8 Fig 9 Fig 6 uk ...
Страница 20: ...20 E n g l i s h trio instruction for installation Fig 10 Fig 12 Fig 11 Fig 13 UK ...
Страница 21: ...21 E n g l i s h trio instruction for installation Fig 18 Fig 14 Fig 16 Fig 15 Fig 17 uk ...
Страница 23: ...23 E n g l i s h trio instruction for installation Notes uk ...
Страница 24: ...DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven ...