background image

8

English

t r i o

 - 

i n s t r u c t i o n

 

f o r

 

i n s ta l l at i o n

 

 Use a parker to fix the clip binding to the pipe on locations that are unreachable after installation;

 

 Apply sufficient clamps, so that the weight of the pipes does not only rest on the appliance;

 

 Determine the remaining length of the roof duct;

 

 Make sure the roof duct has the right dimensions.

!Caution

   Make sure that the right insertion length is maintained.

 

 Connect the roof duct to the concentric pipes.

!Caution

   -   Make sure that the universal tile fits well with the surrounding tiles;

-   Make sure that the adhesive plate fits well onto the flat roof.

6.5.4 Connection of existing chimney flue

It is possible to connect the appliance to an existing channel.
A flexible SS pipe is placed in the chimney for discharging flue gases. The surrounding space is used to supply 
combustion air.
The following requirements apply when connecting to an existing chimney flue:
-   only allowed when used in combination with the special DRU chimney installation set.
The installation regulation is also supplied;
-   the dimensions should be at least 150 x 150 mm;
-   the vertical length has a maximum of 12 meters;
-   the horizontal length has a maximum of 3 meters;
-   the existing chimney flue has to be clean;
-   the existing chimney flue has to be closed.

For adjusting the appliance, the same conditions/instructions apply as for the concentric system described above.

6.6 Connecting gas

Use the following procedure when connecting the gas, see section 6.3 Gas connection:

 

 If necessary, blow through the gas pipe;

 

 Connect the gas pipe with gas tap to the gas control block.

!Caution

   -   You can find the gas control block behind the door in the space at the bottom of the appliance;

-   Do not turn the gas tap when connecting the gas pipe.

 

 Bleed the gas pipe.

6.7  Setting the appliance

The appliance has to be set in such a way that is works correctly in combination with the discharge system.
For that purpose it is possible to install a baffle. For the conditions, see section 6.5.2.1, for application with wall duct 
and section 6.5.3.1, Table 2, for application with roof duct.

6.7.1 Baffle (R)

!Caution

  The restrictor slide should be placed in the correct manner. Therefore, accurately observe the instructions

The baffle (R) is supplied separately.
Follow the procedure below when placing the baffle:

 

 Remove the front pane as indicated in section 6.9.1;

 

 Place the baffle (

see Appendix 4,

 

Fig. 4

);

 

 Use the template supplied to set the distance of the restriction (

see Appendix 4,

 

Fig. 5

) as follows:

-   A distance of 33 mm means that the baffle is closed to a maximum level;
-  A distance of 38, 43, 48 and 60 mm is set by means of a template.

 

 Fix the baffle by using the socket cap screw (S).

6.8 Placing the wood set

The appliance is supplied with a wood set.

Caution

   Strictly observe the following instructions to prevent unsafe situations:

-   only ever use the supplied wood set;
-   place the wood set exactly as described;
-   make sure the pilot burner and the space around it are kept free from objects (

see Appendix 4,

 

Fig. 6

);

-   make sure that the slot between the burner tray and the tray surrounding the burner is kept free from objects.
-  make sure that the vermiculite’s fine dust does not get on the burners.

uk

Содержание G31 Propane

Страница 1: ...1 E n g l i s h Trio G31 Propane Please retain this document carefully Instructions for installation GB IE 959 065 01 uk uk ...

Страница 2: ...is guarantees that the user will be able to enjoy using his product for many years to come This appliance has a CE marking which means that it complies with the essential requirements of the European gas appliance directive As an installer you must be competent in the field of atmospheric gas heating Two manuals are supplied with the appliance the installation manual and the user manual The instal...

Страница 3: ...a copy of the test certificate via www druservice com M J M Gelten General manager Postbus 1021 6920 BA Duiven Ratio 8 6921 RW Duiven www dru nl 3 SAFETY 3 1 General Caution Carefully read this chapter on safety before you start performing installation or maintenance work Please observe the general regulations and the precautions safety instructions in this manual 3 2 Regulations Please install th...

Страница 4: ...egulations 6 Installation Read this manual carefully to ensure a proper and safe operation of the appliance Caution Install the appliance in the order described in this chapter 6 1 Regulations Please install the appliance in accordance with the applicable national local and constructional installation regulations Observe the regulations instructions in this manual 6 2 Type of gas The type plate in...

Страница 5: ...ig 2 First a concentric pipe of at least 1 meter should be connected vertically to the appliance The total vertical pipe length can have a maximum of 4 meters On the vertical part a bend of 90 is connected Only wall ducts are allowed Under these conditions you should not install the restrictor slide 6 5 2 2 Placing concentric system with wall duct Place the concentric system as follows Build the s...

Страница 6: ... of bends required no distinction is made between 45 and 90 bends 2 The total number of meters of horizontal pipe length 3 The total number of meters of vertical and or sloping pipe length These data will help you determine whether the concentric system is allowed by using Table 1 In Table 2 you can read which setting is required for the appliance Follow the procedure described below In the first ...

Страница 7: ...ive plate for a flat roof or with a universally adjustable tile for a sloping roof Place the concentric system as follows Build the system up from the connection stump of the appliance Caution Maintain a distance of at least 50 mm between the outside of the concentric system and the walls and or the ceiling Use heat resistant isolation material when passing through combustible material Caution Som...

Страница 8: ... necessary blow through the gas pipe Connect the gas pipe with gas tap to the gas control block Caution You can find the gas control block behind the door in the space at the bottom of the appliance Do not turn the gas tap when connecting the gas pipe Bleed the gas pipe 6 7 Setting the appliance The appliance has to be set in such a way that is works correctly in combination with the discharge sys...

Страница 9: ...fingerprints on the pane as they will burn into the glass Avoid damages when removing placing the glass pane Make sure the sealing tape at the edges of the glass pane is not damaged during removal 6 9 1 1 Removing the front pane When removing the front pane you should observe the instructions below see Appendix 4 Fig 14 to 17 Open the door Unscrew the 6 parkers of the glass strip at the sides by u...

Страница 10: ...Fig 20 arrow C insert the plug into the wall socket Place the receiver in the control box as indicated on Fig 18 see Appendix 4 o Bend the antenna out of the clips see Appendix 4 Fig 20 arrow D and Fig 21 Set the antenna straight Caution Do not place the antenna too close to the ignition cable and or metal parts for the correct position see Appendix 4 Fig 21 Do not place the ignition cable over an...

Страница 11: ...l the functions for high low position ignition and switching off Tip If the external control system has an intelligent clock function and or thermostat function the remote control sup plied with the appliance should have the manual mode in order to prevent interruption of these functions 2 Clock thermostat mode This mode of the remote control is active and will be responsible for the clock functio...

Страница 12: ...The main burner s must cross the full burner smoothly and without popping and continue to burn Check operation of the main burner from a cold condition pilot flame off After opening the gas valve the main burner should burn within a few seconds Tip When the gas valve is opened the motor will start to run this is audible The flame picture and a good flame transfer can only be properly judged if the...

Страница 13: ...lose the gas tap immediately in case of malfunctions bad performance and contact the installer in order to prevent dangerous situations Indicate the location of the gas tap Point out the precautions in the user manual against unintended ignition by other wireless remote controls such as car keys and garage door openers Instruct the user about the appliance and the remote control When the appliance...

Страница 14: ... See that it does not fall away Clean with compressed air Rectify Retry 2 05 Check Ignition cable Present and connected Being free from metal parts or concrete Too long cut away all excessive length at receiver end and reconnect Shorting out to earth replace ignition cable Spark in wrong position slide rubber sleeve on ignition cable over ceramic of electrode Replace electrode if neccessary Igniti...

Страница 15: ...urner dirty Weak pilot flame being drawn away by flames main burner Clean with compressed air See 2 04 2 15 Check Flames too low Supply pressure does not drop away as main burner or other appliances in the building light causing flames to shorten Burner pressure too low False air Check soundness glass window gasket soundness of the connection of the glass panes of two three sided appliances no slo...

Страница 16: ...e rechargeables by alkaline batteries Communication code between remote and receiver has to be re set Press reset button on receiver until brief beep followed by long beep Release reset button and press flame low button on remote within 20 seconds Then 2 short beeps and brief noise of servomotor to confirm that communication code was set succesfully Remote control Battery 9V empty see indication o...

Страница 17: ...cket spanner 1x Remote control with receiver 1x 9V block battery 1x Penlite battery AA type 4x Squeeze coupling 15 mm x G3 8 1x Appendix 2 Technical data In the following table you can find the technical data Table 6 Technical data Type C11 C31 C91 Type of gas G31 Burner pressure mbar 30 Nom load Hs kW 5 8 Nom load Hi kW 5 2 Nom output kW 4 0 Consumption L h 214 Burner injector mm front Ø 0 90 rea...

Страница 18: ...18 E n g l i s h trio instruction for installation Appendix 4 Figures Fig 4 38 43 48 60 38c 1220 Fig 5 Fig 3 1 4m min 40mm 38c 744g 1x90 Fig 2 Fig 1 UK ...

Страница 19: ...19 E n g l i s h trio instruction for installation Fig 7 Fig 8 Fig 9 Fig 6 uk ...

Страница 20: ...20 E n g l i s h trio instruction for installation Fig 10 Fig 12 Fig 11 Fig 13 UK ...

Страница 21: ...21 E n g l i s h trio instruction for installation Fig 18 Fig 14 Fig 16 Fig 15 Fig 17 uk ...

Страница 22: ...22 E n g l i s h trio instruction for installation O A B 38C 2031 1 Fig 21 Fig 20 38p 0181 Fig 22 38p 0179 Fig 23 5mV 38p 0182 Fig 24 Fig 19 UK ...

Страница 23: ...23 E n g l i s h trio instruction for installation Notes uk ...

Страница 24: ...DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven ...

Отзывы: