6.8.3 Primary aeration of the burners
Caution
Adjusting the primary aeration only applies to appliances used in Belgium.
Whenthetraysurroundingtheburnersisremoved,youcanseethethrottlerings(PaandPb)thataremountedon
thepipesthatarefixedtotheburners(burnerpipes);see
Fig. 9
.
Theprimaryaerationoftheburnerscanbeadjustedbyrotatingthethrottlerings.
Caution
Rotate the throttle ring at the front left (Pb) with its opening towards the pilot fl ame burner. This throttle ring has only
1 hole with a diameter of 6 mm and 1 with a diameter of 12 mm (see
Fig. 9
).
Thestepstobetakenaredescribedbelow:
➠
Take the tray surrounding the burners (M) out of the appliance; see
Fig. 10a
.
➠
Unscrew the socket cap screw (O) of a throttle ring (P), see
Fig. 11
.
➠
Rotate the throttle ring (P) when using gas G25 in such a way, that the holes with the 7 mm diameter are directly op-
posite the 15 mm holes in the burner pipe; see
Fig. 11
.
➠
Screw the socket cap screw (O) into the threaded hole above the 7 mm diameter hole.
➠
Repeat this procedure for the other 3 burner pipes.
➠
Return the tray surrounding the burners (M).
6.9 Arranging the logs
Theapplianceissuppliedwithasetoflogs.
N.B.
Observe the instructions below precisely to avoid unsafe situations.
- only use the log set supplied;
- arrange the logs exactly as described;
- do not cover the pilot burner or the surrounding area;
- make sure that thermocouple 2 and the space around it are kept free from objects (see photo 4c and photo 4d);
- do not cover the slot between the burner tray and the tray surrounding the burner.