background image

 

LOCOPUMP 

S3

 

  Pneumatic Pump 
 

 

User and Maintenance 
Manual  

 

Original text translation 

 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 

Manual compiled in accordance with Directive CE 06/42                        C2255IE WK 13/18 

 

 

 

 

INDEX 

 

1.   

INTRODUCTION 

2.   

GENERAL DESCRIPTION 

3.   

PRODUCT IDENTIFICATION 

4.   

TECHNICAL CHARACTERISTICS 

5.   

COMPONENTS 

6.   

UNPACKING AND INSTALLING 

7.   

OPERATING INSTRUCTIONS 

8.   

TROUBLESHOOTING 

9.   

MAINTENANCE PROCEDURE 

10.  

DISPOSAL 

11.  

ORDERING INFORMATION 

12.  

DIMENSIONS 

13.  

HANDLING AND TRANSPORTATION 

14.  

OPERATING HAZARDS 

15.  

PRECAUTIONS 

 

http://www.dropsa.com 

Via Benedetto Croce, 1 

Vimodrone, MILANO (IT) 

t. +39 02 250791 

 

Dropsa products can be purchased from Dropsa branches and authorized distributors, 

visit 

www.dropsa.com/contact

 or contact us 

[email protected]

 

Содержание LOCOPUMP S3

Страница 1: ...CS 5 COMPONENTS 6 UNPACKING AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERAT...

Страница 2: ...r and an adjustable delivery kit Loading connection is completed of a filter guaranteeing the input of clean lubricant into the reservoir It s possible to use a filtered clean grease return in the res...

Страница 3: ...rease output The level sensor is and electric contact that indicates that the pump has reached its low level of grease It s possible to set it to either Normally Closed or Normally Open see drawing fo...

Страница 4: ...hread that allows interfacing with up to two 400cc lubricant cartridges High Reliability is guaranteed by the use of hardened steel in the construction in all the pumping element components and the pu...

Страница 5: ...LET CONNECTION The hydraulic connection of the pump is on the front face of the pump It is a standard 1 4 BSP see drawing in chapter 12 6 5 AIR CONNECTION ON PUMP Use an 1 8 BSP connection fitting It...

Страница 6: ...ss the start button on the machine to which the Sumo pump is connected Check pump start up Check that the machine is adequately lubricated if there are still some doubts about its correct functioning...

Страница 7: ...le All components must be clean with cleaning fluid and lubricated before re assembly Periodically it is necessary to check CHECK TOTAL NUMBER OF PUMP CYCLES The lubrication status 100 Lubricant level...

Страница 8: ...future maintenance increase the spaces indicated by at least 100 mm 2 Kg 0 5 Kg H 433 272 AIR INLET G1 8 BSP Compression fitting for 6 pipe LUBRICANT OUTLET G1 4 BSP LUBRICANT INLET Valved Greaser UNI...

Страница 9: ...eans of compiling the checklists already made available and contained in the technical file Two types of lists were used List of dangers section from UNI EN ISO 14121 1 relating to UNI EN ISO 12100 Ap...

Отзывы: