11. ORDER INFORMATION 

 

11.1 CANNONPUMP WITHOUT FOLLOWER PLATE AND COVER 

 

Part Number 

Drum  Delivery (Kg) 

Power supply 

0234525 

20-25 

230/400Vac 3Ph – 50Hz – 0.55kW 
240/415Vac 3Ph – 50Hz – 0.55kW

 

280/480Vac 3Ph – 60Hz – 0.65kW 

0234535 

50 

0234545 

180/200 

0234526 

20-25 

110Vac 1Ph – 60 Hz – 0.9 kW 

0234536 

50 

0234546 

180/200 

0234527 

20-25 

230Vac 1Ph – 50Hz – 0.55kW

 

0234537 

50 

0234547 

180/200 

0234528 

20-25 

24Vcc – 0.55kW 

0234538 

50 

0234548 

180/200 

 

11.2 CANNONPUMP WITH FOLLOWER PLATE AND COVER 

 

Part Number 

Drum  Delivery (Kg) 

Power supply 

0234520 

20 

230/400Vac 3Ph – 50Hz – 0.55kW 
240/415Vac 3Ph – 50Hz – 0.55kW

 

280/480Vac 3Ph – 60Hz – 0.65kW 

0234550 

25 

0234530 

50 

0234540 

180/200 

0234521 

20 

110Vac 1Ph – 60 Hz – 0.9 kW 

0234551 

25 

0234531 

50 

0234541 

180/200 

0234522 

20 

230Vac 1Ph – 50Hz – 0.55kW

 

0234552 

25 

0234532 

50 

0234542 

180/200 

0234523 

20 

24Vcc – 0.55kW 

0234553 

25 

0234533 

50 

0234543 

180/200 

 

11.3 SPARE PARTS AND ACCESSORIES 

 

CANNONPUMP can be customized adding a minimum electric level or a laser probe, for other information contact 
Dropsa's Technical Office

 

 Pump Accessories and spare parts 

 

Engines parts

 

Item 

Pump size part number 

 

Part 
Number 

Power supply 

 

20 Kg 

25 kg 

50 kg 

180 / 200 kg 

   

230/400V AC 3Ph – 50Hz – 0.55kW 

Cover 

1141601 

1141606 

1141603 

1141605 

 

3301536 

240/415V AC 3Ph – 50Hz – 0.55kW 

Follower 
Plate 

1141600 

1141607 

1141602 

1141604 

   

280/480V AC 3Ph – 60Hz – 0.65kW 

 

 

 

 

 

 

3301543 

110V AC 1Ph – 60 Hz – 0.9 kW 

 
 Other spare parts

 

 

3301542 

230V AC 1Ph – 50Hz – 0.55kW 

Part Number 

Item 

 

3301540 

24V DC – 0.55kW 

0234496  

 

Bypass 

 

 

 

3133456 

 

200 kg Drum Lift Kit  

 

 

 

Содержание CannonPump

Страница 1: ...ICAL FEATURES 5 MACHINE COMPONENTS 6 UNPACKING AND INSTALLATION 7 INSTRUCTIONS FOR USE 8 PROBLEMS AND SOLUTIONS 9 MAINTENANCE PROCEDURES 10 DISPOSAL 11 ORDER INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORT 14 PRECAUTIONS FOR USE 15 OPERATIONAL HAZARDS 16 WARRANTY 17 DECLARATION OF COMPLIANCE 18 DISTRIBUTORS Manual compiled in accordance with Directive C2124IE WK 47 11 CE 06 42 http www dropsa ...

Страница 2: ...ry and in harsh operating conditions to lubricate multiple points on large machines The system can grow to a very complex one with a length that often can exceed 60 meters The large section of pump packages together with many custom design optionsdallowsoanyolubricationosystemotoobeodevelopedoreliablyeandecost effectively DropsA skilled engineers are available to design large scale project and pro...

Страница 3: ... 240 415Vac 3Ph 50Hz 0 55 kW 280 480Vac 3Ph 60Hz 0 65 kW 110Vac 1Ph 60Hz 0 9 kW 230 1Ph 50Hz 0 55 kW 24Vcc 0 55 kW Pump type Piston mechanism Outlet connection G 3 8 Maximum pressure 250 bar three phases motor 200 mono phase motor Drum capacity 20 kg 25Kg 50Kg 180 Kg 200 Kg Lubricant Grease NLGI 2 max Flow 125 cm3 min Degree of protection IP55 Gear reducer Screw and helical wheel R 50 1 Drum Fixtu...

Страница 4: ...PONENTS 1 Lifting Lug 2 Outlet 3 Oil lamp 4 Oil drain plug 5 Drum cover 6 Identification Label 7 Follower plate 8 Motor 9 By pass 10 Oil Fill plug 11 Return Line plugged 12 Gearbox reducer 13 Pump Shaft 1 2 7 6 5 4 3 8 11 9 10 12 13 ...

Страница 5: ...omponents and associated dangers of electricution Care must be taken when making electrical connection Check the integrity of the terminal box and the pump in general In case of any damage do not put the unit in operation If the power cable has been damaged replace it immediately Dismantling of the unit must be done by qualified maintenance personnel with electrical and mechanical skills In order ...

Страница 6: ...not working No power at the motor Check the power supply system and the fuse 02 The electric motor is working but the pump does not deliver lubricant Air trapped in the outlet or in the lubricant pumping chamber Disconnect the outlet tubing and cycle the pump until clean grease with no air bubbles is pumped from the outlet Reconnect as appropriate 03 The pump is working but no grease arrives at th...

Страница 7: ...o readily detect possible leaks The machine does not require any special tool for checking or maintenance tasks However it is recommended the use only of appropriate and in good conditions tooling protective devices gloves and clothing in according to current regulations to avoid hazards to equipment or persons 10 DISPOSAL The unit does not contain any harmful substances and should be disposed of ...

Страница 8: ...4521 20 110Vac 1Ph 60 Hz 0 9 kW 0234551 25 0234531 50 0234541 180 200 0234522 20 230Vac 1Ph 50Hz 0 55kW 0234552 25 0234532 50 0234542 180 200 0234523 20 24Vcc 0 55kW 0234553 25 0234533 50 0234543 180 200 11 3 SPARE PARTS AND ACCESSORIES CANNONPUMP can be customized adding a minimum electric level or a laser probe for other information contact Dropsa s Technical Office Pump Accessories and spare pa...

Страница 9: ...9 12 DIMENSIONS DRUM DELIVERY kg A B C 20 25 290 315 520 50 365 400 720 180 200 590 600 900 612 ...

Страница 10: ...can often cause skin irritations and therefore appropriate safety measures must be adopted Power supply Any type of intervention must not be carried out before the unplugging of the machine from power supply Make sure that no one can start it up again during the intervention All the installed electric and electronic equipment reservoirs and basic components must be grounded Flammability The lubric...

Страница 11: ...ards have been identified as a result and must be considered during operation During maintenance oil may be discharged at low pressures oil squirt To counter this maintenance must be carried wearing appropriate personal protective clothing and glasses Electricution This can occur if the user does not securely connected the wires inside the terminal box Electrical connections must therefore be carr...

Страница 12: ...f subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform such necessary product repairs or replace such product s at our expense Dropsa reserves to right to charge an administration fee if the product s returned are found to be not defective This limited warranty do...

Страница 13: ...enominación Denominação CANNONPUMP Versioni Versions Versions Versionen Versiones Versões Tutte Codici Codes Códigos Serie 02345 è conforme alle condizioni previste dalle Direttive CEE has been constructed in conformity with the Directives Of The Council Of The European Community on the standardization of the legislations of member states a été construite en conformité avec les Directives Du Conse...

Страница 14: ...uk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerling Hts Mi Us USA Tel 1 586 566 1540 Fax 1 586 566 1541 E mail salesusa dropsa com Dropsa Lubrication Systems Nr 8 Dongxing Road Songjiang Industrial Zone Shanghai Co Ltd Tel 86 021 67740275 Fax 86 021 ...

Отзывы: