DROPSA 0086450 Скачать руководство пользователя страница 5

 

8. PROBLEMS AND SOLUTIONS 

 

TROUBLESHOOTING TABLE

 

PROBLEM 

POSSIBLE CAUSE 

REMEDIAL ACTION 

The modular valve 
doesn’t invert 

Piston jammed

 

Verify correct sliding of piston 

 

Possible replacement valve 

The modular valve has reached the maximum 
pressure level

 

Adjust the pressure to a maximum of 400 bar (5880 psi) 

Important lubricant leakage from one of the four 
connection pipes 
 

Verify piping status and the connections to fittings. 
Replace worn out pipelines 

Gasket broken

 

Replace 

 

Valve leaks 
lubricant 

Breaking of internal gaskets 

Replace 

 

 

Operations by specialized Dropsa personnel (ship the product to Dropsa headquarters)

 

 
 
9. MAINTENANCE PROCEDURE 

 

The  product  does  not  necessitate  any  special  tool  for  operation  and  maintenance.  When  working  with  the  pump  it  is 
nonetheless recommended that personal health and safety equipment is used as is normal for any operation in an industrial or 
similar workplace. 
The pump has been designed and built as to require minimal maintenance and operate in different and challenging operating 
environment.  It  is  recommend  that the  unit  is  inspected  and  kept  clean  to  ensure  long  life  and  trouble  free  operation.  It  is 
important to check all tubing on the system to ensure that it is always tight and leak free. 
 

ITEM 

FREQUENCY 

OPERATION 

Integrity of tubing and system 

After initial 500 hours. 
Every1500 hours. 

Check fittings and tubing secured. 
Verify components are correctly fixed to machine. 

 
 
 
 
 

In any doubts and/or problematic not solved, do not proceed to search by removing machine parts but contact our technical office 

 
 
10. DISPOSAL 

 

During maintenance or disposal of the machine care should be taken to properly dispose of environmentally sensitive items such 
as oils or other lubricants. Refer to local regulations in force in your area. When disposing of this unit, it is important to ensure 
that the identification label and all the other relative documents are also destroyed. 
 

 

 

WARNING:  Before  carrying  out  any  maintenance  operation,  ensure  that  power  and  hydraulic  system  are 

disconnected. 

 

 

Содержание 0086450

Страница 1: ...G AND INSTALLING 7 OPERATING INSTRUCTIONS 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 ORDERING INFORMATION 12 DIMENSIONS 13 HANDLING AND TRANSPORTATION 14 OPERATING HAZARDS 15 PRECAUTIONS http www dropsa com Via Benedetto Croce 1 Vimodrone MILANO IT t 39 02 250791 Dropsa products can be purchased from Dropsa branches and authorized distributors visit www dropsa com contact or contact ...

Страница 2: ...e at 5880 psi 400 bar max pressure The function of this Hydraulic inverter is that both main lines have to be alternately pressurized and be relieved of pressure 3 PRODUCT IDENTIFICATION Machine identification label is located on the front side of the reservoir and contains product serial number input voltage and details of the operating parameters 4 TECHNICAL CHARACTERISTICS GENERAL CHARACTERISTI...

Страница 3: ... line 2 fig 3 with valve in position b the pump pushes lubricant to line 2 Line 1 is discharge phase Exchange line 1 2 fig 2 when fluid reaches the adjusting spring pressure calibration PS1 the pilot conduit opens causing the displacement of the chamber from the position b to the position a Activation line 1 fig 1 with valve in position a the pump pushes lubricant to line 1 Line 2 is discharge pha...

Страница 4: ...ONS 7 1 Start up Before using the product a few preliminary checks must be performed Check Modular directional valve integrity Check that the valve is at running temperature and that the pipes are free of air pockets Check that the electrical connection has been carried out correctly Check that there aren t lubricant leakage or air pressure loss Check that the lock screws are properly screwed up U...

Страница 5: ...mp has been designed and built as to require minimal maintenance and operate in different and challenging operating environment It is recommend that the unit is inspected and kept clean to ensure long life and trouble free operation It is important to check all tubing on the system to ensure that it is always tight and leak free ITEM FREQUENCY OPERATION Integrity of tubing and system After initial...

Страница 6: ...n Part Number Pressure gauge Kit 3133910 Ultrasensor 1655305 M12 female connector 0039999 M12 female connector cable L 5 mt 0039815 11 2 Spare parts Description Part Number OR gasket valve pump 3190500 Right pressure gauge 3292172 Left pressure gauge 3292171 Positioning pressure gauge optional Positioning Ultrasensor optional ...

Страница 7: ...ection indicated on the boxes themselves Upon receipt check that the package has not been damaged and store the equipment in a dry location 14 OPERATING HAZARDS Flammability The lubricant generally used in lubrication systems is not normally flammable However it is advised to avoid contact with extremely hot substances or naked flames Pressure Before each operation make sure there in every branch ...

Страница 8: ...ge from the pump Always use appropriate protective clothing gloves and take all necessary safety precautions Contact with lubricant during maintenance or filling of the reservoir As per previous point correct precautions must be taken to protect from contact with lubricant Electric shock All electrical connections must be carried out by a qualified electrician who has studied the connection to ens...

Отзывы: