A = 12" Clearance above grade, veranda, porch, deck or balcony
B = 12" Clearance to window or door that may be opened
C = 12" Clearance to permanently closed window
D = 18" Vertical clearance to ventilated soffit located above the terminal within a horizontal
distance of 2 feet (60 cm) from the centre-line of terminal (straight out or corner
installation)
D = 24" (Basement or distant installation)
E = 12" Clearance to unventilated soffit (straight out or corner installation)
E = 24" (Basement or distant installation)
F = 12" Clearance to outside corner
G =12" Clearance to inside corner
H = Not to be installed above a meter/regulator assembly within 3 feet (90 cm) horizontally from
the centre-line of the regulator *
I = 72" Clearance to service regulator vent outlet
J = 12" Clearance to non-mechanical air supply inlet to building or the combustion air inlet to
any other appliance
K = 72" Clearance to a mechanical air supply inlet
L = 84"
Clearance above paved sidewalk or a paved driveway located on public property
M =36"
Clearance under veranda, porch, deck, or balcony