PART B - INSTALLATION
6 Safety Information
6.1 Summary of Installation Cautions and Warnings
•
THE INFORMATION GIVEN ON THE CERTIFICATION LABEL AFFIXED TO THE
APPLIANCE ALWAYS OVERRIDES THE INFORMATION PUBLISHED, IN ANY
OTHER MEDIA (OWNER’S MANUAL, CATALOGUES, FLYERS, MAGAZINES
AND/OR WEB SITES).
•
MIXING OF APPLIANCE COMPONENTS FROM DIFFERENT SOURCES OR
MODIFYING COMPONENTS MAY RESULT IN HAZARDOUS CONDTIONS. WHERE
ANY SUCH CHANGES ARE PLANNED, STOVE BUILDER INTERNATIONAL INC.
SHOULD BE CONTACTED IN ADVANCE.
•
ANY MODIFICATION OF THE APPLIANCE THAT HAS NOT BEEN APPROVED IN
WRITING BY THE TESTING AUTHORITY VIOLATES CSA B365 (CANADA), AND
ANSI NFPA 211 (USA).
•
CONNECT THIS STOVE ONLY TO A LISTED FACTORY-BUILT CHIMNEY FOR
USE WITH SOLID FUEL OR TO A LINED MASONRY CHIMNEY CONFORMING TO
NATIONAL AND LOCAL BUILDING CODES.
•
IF REQUIRED, A SUPPLY OF COMBUSTION AIR SHALL BE PROVIDED TO THE
ROOM OR SPACE.
•
DO NOT CONNECT TO OR USE IN CONJUNCTION WITH ANY AIR DISTRIBUTION
DUCTWORK UNLESS SPECIFICALLY APPROVED FOR SUCH INSTALLATION.
•
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE.
•
DO NOT INSTALL IN A MOBILE HOME
6.2 Regulations Covering Stove Installation
When installed and operated as described in these instructions, the Pyropak wood stove is
suitable for use as a freestanding heater in residential installations. The Pyropak wood
stove is not recommended for installation in a sleeping room.
In Canada, the CSA B365 Installation Code for Solid Fuel Burning Appliances and
Equipment and the CSA C22.1 Canadian National Electrical Code are to be followed in the
absence of local code requirements. In the USA, the ANSI NFPA 211 Standard for
Chimneys, Fireplaces, Vents and Solid Fuel-Burning Appliances and the ANSI NFPA 70
National Electrical Code are to be followed in the absence of local code requirements.
This stove must be connected to a chimney complying with the requirements for Type HT
chimneys in the Standard for Factory-Built Chimneys for Residential Type and Building
Heating Appliances, UL 103 and ULC S629 or to a code-approved masonry chimney with
a flue liner.