HT-2000 Installation and Operation Manual
32
7.3 Floor protector
Your stove has been conceived to prevent the floor from overheating. However, it must be
placed on a noncombustible surface to protect the floor from hot embers that could fall
from the stove while loading or cleaning. There are differences between floor protections in
Canada and in the United States, as it is illustrated in the table below and on the figure
Clearances to combustible materials and floor protection.
FLOOR PROTECTOR*
CANADA USA
G
8’’ (203 mm) – Note 1
N/A (Canada only)
H
8’’ (203 mm)
N/A (Canada only)
I
18’’ (457 mm)
From door opening
16’’ (406 mm)
From door opening
J
N/A (USA only)
8’’ (203 mm)
M
8’’ (203 mm)
N/A (Canada only)
N
N/A (USA only)
Note 2
*Steel with a minimum thickness of 0.015’’ (0.38 mm) or ceramic tiles sealed together
with grout. No protection is required if the unit is installed on a non-combustible floor
(ex: concrete).
Note 1:
The floor protection at the back of the stove is limited to the stove’s required
clearance if such clearance is smaller than 8 inches (203 mm).
Note 2:
Only required under the horizontal section of the connector. Must exceed each
side of the connector by at least 2 inches (51 mm).
Содержание HT-2000
Страница 8: ...HT 2000 Installation and Operation Manual 8 ...
Страница 9: ...HT 2000 Installation and Operation Manual 9 ...
Страница 31: ...HT 2000 Installation and Operation Manual 31 Clearances to combustible materials and floor protection ...
Страница 34: ...HT 2000 Installation and Operation Manual 34 Clearances for shield construction ...
Страница 46: ...HT 2000 Installation and Operation Manual 46 3 Press the ashtray trim F on the upper edge of ashtray lip ...
Страница 52: ...HT 2000 Installation and Operation Manual 52 Appendix 6 Exploded Diagram and Parts List ...