Page 15
Installation and Operation Manual - Wood Stove
ENGLISH
3.1.3 With Heat Shield AC02762 and Lowered Ceiling
To reduce the clearances of an appliance using a single wall pipe connector, the use of a heat
shield certified with the single wall pipe connector to be used as close as 6" from combustible
materials must be used. Only in this case, the same clearances as a certified double wall pipe
connector can be used . Refer to the booklet in the screen options to obtain the dimensions to
be respected.
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada
USA
A
5" (127 mm)
5" (127 mm)
B
6" (152 mm)
6" (152 mm)
C
5" (127 mm)
5" (127 mm)
L
80" (2032 mm)
80" (2032 mm)
Ve
Ho
L
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada
USA
D
8 ¼" (210 mm)
8 ¼" (210 mm)
E
15 ¼" (387 mm)
15 ¼" (387 mm)
F
14 ½" (368 mm)
14 ½" (368 mm)
F
F
C
A
B
E
D
17
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.