Edison Installation and Operation Manual
61
o
If the hopper auger is jammed, start by emptying the hopper. If it is the burn pot
auger you don’t need to empty the hopper. To remove both augers from their
housing you need to disconnect auger motor and then remove the four screws on
the steel plate that holds the auger shaft to the auger housing. You may need to
remove the rear panel for an easier access. Pull out the auger from the housing.
Once the auger has been removed, make sure there are no metal flows, burrs, or
broken welds. Remove any foreign material that may have caused the jam. Inspect
the auger housing for signs of damage such as burrs, rough spots, or grooves cut
into the metal that could have caused a jam. Clean the auger housing thoroughly to
remove all pellet dust.
The wiring harness shorted. Make sure the auger motor wiring is properly connected
and not shorted.
9.3.6 Unit Overheat
Inadequate fuel is used. Remove the burn pot, make sure that all openings are clear
and check that no ash has filled the tube around the igniter. Refer to the maintenance
section. Also, make sure that the recommended fuel is used (see Section 5.2.1:
Proper Fuel).
The flue is not properly installed. Make sure the venting system meets the criteria in
the Section 4: Venting System as well as the venting system manufacturer’s
instructions.
The flue is blocked or needs cleaning. One of the following components is
obstructed or blocked; air intake shutter, combustion blower, burn pot, heat exchangers
and channels, exhaust blower and or venting system. Refer to Section 8:
Maintenance.
The stove needs maintenance. Refer to Section 8: Maintenance.
The burn pot is not installed properly. Make sure the burn pot is installed correctly
(see Section 8.1.4: Cleaning the Burn Pot).
The baffle is not installed properly or holes may be blocked. Make sure the baffle
is well installed and the lock is in place. Make sure the holes are clear. (see Section
8.1.2: Cleaning the Baffle, the Heat Exchanger and the Combustion Chamber).
The convection blower is defective. Go to the troubleshooting page on the LCD
touch screen and test the convection blower (see Section 9.2: Testing Components).
Содержание DP00065
Страница 13: ...Edison Installation and Operation Manual 13 STEP 3 STEP 4 G INSULATING FILM H BUTTON BATTERY CR2032 ...
Страница 77: ...Edison Installation and Operation Manual 77 Unplug the temperature sensor C Remove the clamp D ...
Страница 82: ...Edison Installation and Operation Manual 82 15 Replacement Parts ...
Страница 83: ...Edison Installation and Operation Manual 83 ...
Страница 84: ...Edison Installation and Operation Manual 84 ...
Страница 85: ...Edison Installation and Operation Manual 85 ...
Страница 86: ...Edison Installation and Operation Manual 86 ...
Страница 87: ...Edison Installation and Operation Manual 87 ...
Страница 88: ...Edison Installation and Operation Manual 88 ...
Страница 89: ...Edison Installation and Operation Manual 89 ...