Page 6
Installation and Operation Manual - Escape 1200
ENGLISH
2. General Information
2.1 Performances
Values are as measured per test method, except for the recommended heating area, firebox volume,
maximum burn time and maximum heat output.
Model
Escape 1200 (DB03182)
Combustion type
Non-catalytic
Fuel Type
Dry Cordwood
Recommended heating area (sq. ft.
.
)
1
250 to 1,200 ft
2
(23 to 111 m
2
)
Total firebox volume
1.7 ft
3
(0.0481 m
3
)
EPA loading volume
1.55 ft
3
(0.0439 m
3
)
Maximum burn time
1
5 hours
Maximum heat output (dry cordwood)
2
45,000 BTU/h (13.2 kW)
Overall heat output rate (min. to max.)
2 3
12,124 BTU/h to 26,700 BTU/h
(3.55 kW to 7.83 kW)
Average overall efficiency
3
(Dry cordwood)
74 % (HHV)
4
79
% (LVH)
5
Optimum efficiency
6
80 %
Optimum heat transfer efficiency
7
79 %
Average particulate emissions rate
8
1.8 g/h (EPA / CSA B415.1-10)
9
Average CO
10
74
g/h
1
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,heat loss factors, climate, fuel type
and other variables. The recommended heated area for a given appliance is defined by the manufacturer as its capacity to maintain a minimum
acceptable temperature in the designated area in case of a power failure.
2
The maximum heat output (dry cordwood) is based on a loading density varying between 15 lb/ft³ and 20 lb/ft³ and reloading intervals ranging
from 60 to 120 minutes. Other performances are based on a fuel load prescribed by the standard without any reloading between start and finish.
The specified loading density varies between 7 lb/ft³ and 12 lb/ft³. The moisture content is between 19% and 25%.
3
As measured per CSA B415.1-10 stack loss method.
4
Higher Heating Value of the fuel.
5
Lower Heating Value of the fuel.
6
Optimum overall efficiency at a specific burn rate (LHV).
7
The optimum heat transfer efficiency is for the low burn rate and represents the appliance’s ability to convert the energy contained in the wood logs
into energy transferred to the room in the form of heat and does not take into account the chemical losses during combustion.
8
This appliance is officially tested and certified by an independent agency.
9
Tested and certified in compliance with CFR 40 part 60, subpart AAA, section 60.534(a)(1(ii) and ASTM E3053-17 based on the ALT-125 sent by EPA
on February 28
th
, 2018.
10
Carbon monoxide.