Drolet COMPAK EPA EXEMPT Скачать руководство пользователя страница 19

 

 

18 

 

DROLET LIMITED LIFETIME WARRANTY 

 

The  warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty 
covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. Proof of 
purchase  (dated  bill  of sale), model name and serial number must be supplied when making any warranty claim to your 
DROLET dealer.   

This  warranty  applies  to  normal  residential  use  only.    Damages  caused  by  misuse,  abuse,  improper  installation, 
lack of maintenance, over firing, negligence or accident during transportation are not covered by this warranty. 

This warranty does not cover any scratch, corrosion, warping, or discoloration caused by over firing, abrasives or chemical 
cleaners. Any defect or damage caused by the use of unauthorized parts or others than original parts void this warranty. An 
authorized qualified technician must perform the installation in accordance with the instructions supplied with this product 
and  all  local  and  national  building  codes.  Any  service  call  related  to  an  improper  installation  is  not  covered  by  this 
warranty. 
The manufacturer may require that defective products be returned or that digital pictures be provided to support the claim. 
Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the 
manufacturer will repair or replace such defect and reasonable transportation fees will be refunded. Repair work covered 
by the warranty, executed at the purchaser’s domicile by an authorized qualified technician requires the prior approval of  
the  manufacturer.  Labour  cost  and  repair  work  to  the  account  of  the  manufacturer  are  based  on  predetermined  rate 
schedule  and  must  not  exceed  the  wholesale  price of the replacement part. All labour and  freight costs covered by this 
warranty are  limited according to the table below.   

The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the 
defect. The manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by refunding 
the wholesale price of any warranted but defective parts The manufacturer shall in no event be responsible for any special, 
indirect, consequential damages of any nature, which are in excess of the original purchase price of the product. 

 

DESCRIPTION 

WARRANTY APPLICATION 

PARTS 

LABOUR 

Combustion chamber (welds only), castings, and convector airmate 

Lifetime 

5 years 

Plating (defective manufacture) – subject to limitations above 

Lifetime 

n/a 

Secondary air tubes, vermiculite baffle, C-Cast baffle and  handle 
assembly 

5 years 

n/a 

Stainless steel baffle and parts 

5 years 

3 years 

Carbon steel baffle and parts 

2 years 

1 year 

Blowers, thermal switches, rheostat, and other controls 

2 years 

1 year 

Paint (peeling), gaskets, insulation, and ceramic glass (thermal breakage 
only*) 

1 year 

n/a 

*Pictures required 

 

Shall your unit or a components be defective, contact immediately your 

DROLET 

 dealer. Prior to your call make sure 

you have the following information necessary to your warranty claim treatment: 

 

 

Your name, address and telephone number;  

 

Bill of sale and dealer’s name; 

 

Serial number and model name as indicated on the 
nameplate fixed to the back of your unit; 

 

Nature of the defect and any relevant information. 

 

Before shipping your unit or defective component to our plant, you must obtain from your DROLET dealer an 

Authorization Number. Any merchandise shipped to our plant without authorization will be refused automatically and 

returned to sender. 

Содержание COMPAK EPA EXEMPT

Страница 1: ...NS MANUAL DROLET COMPAK EPA EXEMPT US ENVIRONMENTAL PROTECTION AGENCY 28A CERTIFIED WOODSTOVES Verified and tested following UL 1482 Standards by Manufactured by STOVE BUILDER INTERNATIONAL INC 1700 Leon Harmel Quebec Quebec G1N 4R9 Tel 418 527 3060 Fax 418 527 4311 www drolet ca ...

Страница 2: ...4 ASH DISPOSAL 15 AIR CIRCULATION SYSTEM 16 MAINTENANCE 16 GLASS 16 GASKETING 16 PAINT 17 WHEN DO I NEED TO REPLACE THE FIREBRICKS 17 REPLACEMENT PARTS 17 DROLET LIMITED LIFETIME WARRANTY 18 REGISTER YOU WARRANTY ONLINE To receive full warranty coverage you will need to show evidence of the date you purchased your stove Keep your sales invoice We also recommend that you register your warranty onli...

Страница 3: ...low the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obtain a permit Make sure you keep this instruction manual It will always be helpful We also suggest that you consult our web site at www...

Страница 4: ...3 ASSEMBLY Legs installation Position the stove on its back and screw the legs in place with 8 screws 8 bolts and 8 washers Ash lip Installation Screw in place with 2 bolts 2 screws and 2 washers ...

Страница 5: ... of the flue collar are parallel to the back of the stove 3 Fix the flue collar with the hardware supplied 4 Install the flue damper inside the flue collar as illustrated Back air intake ash dump cap and firebricks installation 1 Slide the back air intake A behind the bracket welded on the back of the stove 2 Install the bottom firebricks first then the side ones 3 Install the back firebricks 4 In...

Страница 6: ... SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in an area that will favour the most efficient heat distribution possible throughout the house The stove must therefore be installed in the room where the most time is spent and in the most spacious room possible Recall that wood stoves produce...

Страница 7: ... must be at least 7 84 in all cases The clearance between the flue pipe and a wall are valid only for vertical walls and for vertical flue pipe The flue pipe must not go through roof trussing an attic a wardrobe a floor a combustible partition or similar spaces A flue pipe crossing a combustible wall must have a minimum clearance of 18 To reduce flue pipe clearances from combustible materials cont...

Страница 8: ...ove s performance is directly dependent on an adequate draught from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connect this unit to a chimney flue serving another appliance 2 It must rise above the roof at least 3 0 9 mm from the uppermost point of contact 3 The chimney must exceed any part of the building or other obstruction within a 10...

Страница 9: ...aight All sections installed horizontally must slope at least 1 4 inch per foot with the upper end of the section toward the chimney To insure a good draught the diameter of the coupling pipe should be 6 and total length should never exceed 8 to 10 24 to 3 04 m Except for cases of vertical installation cathedral roof style where the smoke exhaust system can be much longer and connected without pro...

Страница 10: ...9 TYPICAL INSTALLATIONS FACTORY BUILT CHIMNEY ROOF FLASHING 18 CLEARANCE WALL SUPPORT WALL RADIATION SHIELD RAIN CAP Wall installation CEILING SUPPORT RADIATION SHIELD Vertical installation ...

Страница 11: ...10 MASONRY CHIMNEY Clay liner Thimble Clean out door ...

Страница 12: ...11 FACTORY BUILT THIMBLE ...

Страница 13: ...12 BRICK THIMBLE ...

Страница 14: ... 17 Hemlock 17 Low energy yield Spruce 17 Pine 17 Bass 16 Fir 13 Data provided by Energy Mines and Resources Canada IT IS EXTREMELY IMPORTANT THAT YOU USE DRY WOOD ONLY IN YOUR WOOD STOVE The wood must have dried for 9 to 15 months such that the humidity content in weight is reduced below 20 of the weight of the log It is very important to keep in mind that even if the wood has been cut since one ...

Страница 15: ...in your stove for the first four hours of operation Make sure that there s enough air circulation while curing the stove The odours could be smelled during the 3 or 4 first fires Never start your stove outside You will not be able to see if you are over heating IGNITION Place several rumpled sheets of paper in the centre of the combustion chamber Place 8 to 10 pieces of small dry kindling wood ove...

Страница 16: ...shes are disposed of by burial in soil or otherwise locally dispersed they should be retained in the close container until all cinders have thoroughly cooled CAUTIONS ASHES COULD CONTAIN HOT EMBERS EVEN AFTER TWO DAYS WITHOUT OPERATING THE STOVE THE ASH PAN CAN BECOME VERY HOT WEAR GLOVES TO PREVENT INJURY NEVER BURN THE STOVE WITH THE ASH TRAP OPEN THIS WOULD RESULT IN OVER FIRING THE STOVE DAMAG...

Страница 17: ...ately Do not abuse the glass door by striking or slamming shut Do not use the stove if the glass is broken If the glass on your stove breaks replace only with glazing supplied from the Drolet dealer To replace the glass remove the screws retaining the glass mouldings inside the door Remove the mouldings and replace the damaged piece with a new one Perform the procedure backwards after replacing Wh...

Страница 18: ...mes and embers Without firebricks your stove would wear out prematurely It could also become to hot and cause objects or structures nearby to catch fire If you notice that some firebricks are disintegrated and the steel is directly in contact with the fire or embers replace the firebricks immediately If you only notice cracks on some firebricks it is not necessary to replace them The frequency at ...

Страница 19: ...acturer are based on predetermined rate schedule and must not exceed the wholesale price of the replacement part All labour and freight costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all ...

Отзывы: