background image

 

25

 
2.3 CHIMNEY 

CONNECTOR 

 

Your chimney connector (commonly called stove pipe) and chimney must have the same diameter as the 
stove’s exhaust outlet. The stove pipe must be made of aluminized or cold roll steel with a minimum 24-
gauge thickness (0.021" or 0.53 mm).  It is strictly forbidden to use galvanized steel. 

 
The following recommendations may be useful for the installation of your chimney connector: 
 

 

Your chimney connector should be assembled in such a way that the male end (crimped) faces down 
to prevent creosote dripping outside the joints. Attach each of the sections to one another with three 
equidistant metal screws.  Also use three equidistant metal screws  to attach the connector  to the 
stove’s exhaust collar.  See Figure 2.3 (A) and Figure 2.3 (B). 

 

The pipe must be short and straight.  All sections installed horizontally must slope at least ¼  inch per 
foot, with the upper end of the section toward the chimney. See Figure 2.3 (B). 

 

To insure a good draft, the total horizontal length of the connector should never exceed 8' to 10' (2.4  
to 3.04 m).  In the case of  vertical installation, the total length of the connector can be much longer 
and connected without problem to the chimney at the ceiling level. 

 

There should never be more than two 90 degrees elbows in the whole connector and chimney system. 
Never start with a 90

o

 elbow.  Always go up vertically for at least 2 feet from the flue spigot before 

using a 90

o

 elbow. 

 

The connector must not pass through any combustible material, nor may it pass through a concealed 
space (such as an attic, roof space, or closet). If passing through a wall, ceiling, or into a masonry 
chimney, use either chimney components listed for that specific use, or means acceptable to local 
authorities having jurisdiction over the installation. 

 

Installation of a "barometric draft stabiliser" (fireplace register) on a connector is not recommended. 

 

Furthermore, installation of a draft damper is prohibited. Indeed, with a controlled combustion wood 
stove, the draft is regulated upon intake of the combustion air in the stove and not at the exhaust. 

 

 

FIGURE 2.3 (A)  Connecting Sections 

 
 
 

Содержание CLASSIC EPA

Страница 1: ... WOOD STOVE US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOOD STOVE Verified and tested following ULC S627 and UL 1482 Standards by Manufactured by STOVE BUILDER INTERNATIONAL INC 1700 Léon Harmel Québec Québec G1N 4R9 Tel 418 527 3060 Fax 418 527 4311 www drolet ca ...

Страница 2: ...ay result in property damage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installation requirements in your area and the need to obtain a permit KEEP THIS INSTRUCTIONS MANUAL FOR FUTURE REFERENCE CAUTIONS HOT WHILE IN OPERATION KEEP CHILDREN CLOTHING AND FURNITURE AWAY CONTACT MAY CAUSE SKIN BURNS DO NOT USE CHEMICALS OR FLUIDS TO ...

Страница 3: ...ough an existing masonry chimney 22 2 3 CHIMNEY CONNECTOR 25 2 4 DRAFT 27 2 5 OUTSIDE COMBUSTION AIR 27 2 6 THE ADVANTAGE OF INSTALLING A BLOWER FAN 28 SECTION 3 0 OPERATION 29 3 1 SAFETY INFORMATION 29 3 2 FUEL 31 3 2 1 The use of manufactured logs 32 3 2 2 Simple wood moisture test 32 3 3 NOTES ABOUT FIRST FIRING 32 3 4 LIGHTING A FIRE 32 3 5 MAINTAINING THE FIRE 33 3 6 FAN BLOWER OPERATION 34 S...

Страница 4: ...notice a difference between the BTU output as indicated on the unit s white EPA label affixed to the glass and the BTU as advertised on our web site and or product literature The maximum BTU output we advertise for this unit is what will be obtained with a full load of seasoned cordwood inserted inside the firebox The EPA output on the other hand is what has been obtained during emissions testing ...

Страница 5: ...se a chimney thermometer installed at a distance of approximately 18 inches on the flue pipe above the stove Flue gases should reach at least 350oF before you close the stove s primary air intake completely Operate your unit within the comfort zone indicated on the thermometer 9 To reduce the risk of smoke spillage into the room upon reloading your stove leave the primary air intake completely ope...

Страница 6: ...HE DIMENSIONAL SPECIFICATION OF COMPONENTS MAY RESULT IN HAZARDOUS CONDITIONS WHERE SUCH ACTION IS CONSIDERED THE MANUFACTURER SHOULD BE CONSULTED IN THE FIRST INSTANCE DO NOT CONNECT THIS UNIT TO ANY AIR DISTRIBUTION SYSTEM CRACKED AND BROKEN COMPONENTS e g GLASS PANELS OR CERAMIC TILES MAY RENDER THIS INSTALLATION UNSAFE A SOURCE OF FRESH AIR INTO THE ROOM OR SPACE HEATED SHALL BE PROVIDED WHEN ...

Страница 7: ...so as to maintain the minimum clearances to combustible walls specified for each type of connector used See Table 1 3 below for all clearance measures Refer to Figure 1 3 for a diagram of each of the measures A through C Single walled connector Listed double walled connector Unit To sidewall A 18 406 mm 18 406 mm To back wall B 18 406 mm 18 406 mm To corner C 12 305 mm 12 305 mm TABLE 1 3 Clearanc...

Страница 8: ...at radiation shield the clearances mentioned on the stove certification plate may be reduced as stated in the following table TYPE OF PROTECTION Reducing Clearances With Shielding Sides and Rear Back Top Sheet metal a minimum of 0 024 0 61mm spaced out at least 1 25mm by non combustible spacers see graphic 2 67 50 Ceramic tiles or an equivalent non combustible material on fire proof supports space...

Страница 9: ...tection B 500 mm 20 po minimum C 25 mm 1 po minimum D Between 25 mm 1 po and 75 mm 3 po E 75 mm 3 po minimum F 450 mm 18 po minimum 1 Wall shielding 2 Non combustible spacers 3 Ceiling shielding 4 Combustible wall 5 Ceiling 6 Heater side view 7 Heater top view ...

Страница 10: ... 2 Non combustible spacer 3 Fire proof support 4 Ceramic tile or equivalent non combustible material _____________________________________________________________________________ Graphic 4 A 25 mm 1 po minimum 1 Combustible wall 2 Non combustible spacer 3 0 61 mm 0 024 sheet metal 4 Fire proof support 5 Ceramic tile or equivalent non combustible material ...

Страница 11: ...10 Graphic 5 A 25 mm 1 po minimum 1 Combustible wall 2 Non combustible spacer 3 Brick Graphic 6 A 25 mm 1 po minimum 1 Combustible wall 2 Non combustible spacer 3 0 61 mm 0 024 sheet metal 4 Brick ...

Страница 12: ...le material extending at least 18 300mm from the front and 8 200mm from the sides and the back of the firebox as shown in Figure 1 4 below Please refer to local building codes for suitable floor protection materials FRONT 18 300 mm SIDES 8 200 mm BACK 8 200 mm FIGURE 1 4 Floor protector CAUTION DO NOT INSTALL IN A BEDROOM ...

Страница 13: ...tory built chimney with insulation or any other material Insulation placed in this area could cause adjacent combustibles to overheat Do not use makeshift compromises during installation as they may be safety hazards and a fire could result Do not connect this unit to a chimney system serving another appliance Do not cut rafters or ceiling joists without first consulting a building official to ens...

Страница 14: ...2 0 6 m See Figure 2 2 The minimum overall height of the chimney system measured from the stove top to the exterior termination cap of the chimney should be at least 12 3 66m A chimney which is too short may lack the tunnel effect required to obtain a proper draft Installation of an interior chimney is always preferable to an exterior chimney Chimneys constructed outside of the home on an exterior...

Страница 15: ...t system If your chimney must rise along an outside wall you need to connect it to your stove through an adjacent wall For this type of installation the following items are normally required Chimney Suitable lengths of chimney enough to go up to your roof An adjustable wall support A wall thimble An adequate number of wall bands one for every 8 feet of chimney excluding the roof portion A stove pi...

Страница 16: ...chimney will pass through the wall You will probably have to adjust the stove position slightly to ensure that your chimney will run between the studs You can use a stud finder to locate the studs Use a spoke saw or jig saw to cut a hole remembering that you need to maintain a clearance of 2 inches between the chimney and any combustible materials For concrete walls cut a hole slightly larger than...

Страница 17: ...ions through concrete walls 3 You must first secure the wall thimble into the exterior wall surface Then do the same inside and fasten the trim plate 4 Then from outside the building slide a short chimney length attached to the tee through the wall thimble The chimney must extend at least 3 inches into the living space where it attaches to the stove pipe ...

Страница 18: ... using wall bands Wall bands wrap around the chimney and then attach to the wall Install the first one 3 feet above the wall support Then you will need another band for each 8 feet of chimney Note if your chimney must be installed through your soffit install a roof flashing above and finishing plate below where the roof is cut Consult the following section called CEILING SUPPORT SYSTEM for more de...

Страница 19: ...al called CHIMNEY CONNECTOR Ceiling support system If your chimney must rise inside the house and go through the ceiling you need to connect it to your stove at the ceiling level For this type of installation the following items are normally required Chimney An adequate number of chimney sections enough to go up to your roof A ceiling support kit with stove pipe adapter An attic insulation shield ...

Страница 20: ...een the joists You can use a stud finder to locate the joists You also need to take into account the minimum clearances to combustible materials After you have determined where the chimney will go through the ceiling use a spoke saw or power jig saw to cut a hole remembering that you need a minimum 2 inch clearance between the chimney and any combustible materials Depending on whether you have a o...

Страница 21: ...g plate is flush with the underside of the ceiling and assembly is level secure it with screws 4 Once the support is secure you can begin to assemble the chimney by lowering the first section into the support Make sure that the male coupler is pointing upwards as indicated by the arrow on the chimney label 5 Then from beneath the support insert the stove pipe adapter and twist lock it into place ...

Страница 22: ...ur roof and framed the joists it is time to work outdoors Authorities require that the chimney extend not less than 3 feet above the highest point where it passes through the roof of a building and not less that 2 feet above any portion of the building within 10 feet You will need to install a roof flashing The roof flashing slides over your chimney pipe and goes under your shingles Once you have ...

Страница 23: ...can also install your stove using your existing masonry chimney To do so follow the guidelines below You may want to use a factory built thimble on construct your own brick thimble If you are using a masonry chimney it is important that it be built in compliance with the specifications of the Building Code in your region It must normally be lined with fire clay bricks metal or clay tiles sealed to...

Страница 24: ...23 FIGURE 2 2 2 B Factory Built Thimble ...

Страница 25: ...24 FIGURE 2 2 2 C Brick Thimble ...

Страница 26: ...od draft the total horizontal length of the connector should never exceed 8 to 10 2 4 to 3 04 m In the case of vertical installation the total length of the connector can be much longer and connected without problem to the chimney at the ceiling level There should never be more than two 90 degrees elbows in the whole connector and chimney system Never start with a 90o elbow Always go up vertically...

Страница 27: ...26 FIGURE 2 3 B Minimum Slope Avoid 90 degree eblows We recommend that you use two 45 degree elbows instead ...

Страница 28: ... in the vertical chimney connector to help reduce excessive draft 2 5 OUTSIDE COMBUSTION AIR It is recommended to install 4 outside air intake in the room where the stove is located or nearby The following are signs that a fresh air kit may be required Your stove does not draw steadily smoke rollouts occur wood burns poorly or back draft occurs whether or not there is combustion present Existing f...

Страница 29: ...to redistribute into a room the heat trapped at the back of your stove By forcing hot air toward the front the blower enables you to extend the radiation and convection power of your stove You can purchase this option through your Drolet dealer Make sure to specify this part number AC03095 Installation instructions are supplied with the blower ...

Страница 30: ...OUR STOVE CAUTION THIS APPLIANCE SHOULD BE MAINTAINED AND OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE INSTRUCTIONS THE USE OF SOME TYPES OF PRESERVATIVE TREATED WOOD AS A FUEL CAN BE HAZARDOUS 3 1 SAFETY INFORMATION This stove is designed for safe operation WHEN BURNING WOOD ONLY Altering or modifying the unit or installation without proper authorisation will void the certification warranty and...

Страница 31: ... does not exceed 900o F 482o C If you are using a magnetic thermometer make sure that the temperature does not exceed 475o F 246o C If the door handle of the stove becomes excessively hot to the touch consider this to be an indication of over firing Over firing can result in a safety hazard and can permanently damage the stove and chimney This damage is not covered by the warranty Although the cer...

Страница 32: ...eal Dry seasoned cord wood can be distinguished from green wood by the cracks at each end of the logs Wet or green wood will tend to cause the fire to smoulder producing large amounts of creosote Creosote buildup could result in a chimney fire This wood will also prove difficult to keep burning properly and fires will tend to go out Green wood produces very little heat and sometimes causes custome...

Страница 33: ...rmal operating range 3 2 2 Simple wood moisture test Add one large piece of wood to the top of an established fire If it starts to burn on three sides within one minute it is dry and seasoned and right for burning If it turns black and starts to burn in about three minutes or more it is damp If it turns black and does not start burning until five minutes or more it is green and wet If it hisses at...

Страница 34: ...ombustion in the stove Then bring the red embers to the front of the stove and reload the unit Depending on the type of wood you burn and the strength of the draft in your flue you may have to leave the air control open to its maximum for more than 15 seconds to avoid smoke spillage before you reload the stove Your Drolet stove will work best if a thick bed of hot embers is maintained in the botto...

Страница 35: ...y one hour before turning on the fan The increased airflow from the fan will cool the firebox and affect the start up combustion efficiency if the fan is turned on too quick CAUTION ENSURE THAT THE FAN S POWER CORD IS NOT IN CONTACT WITH ANY SURFACE OF THE STOVE TO PREVENT ELECTRICAL SHOCK OR FIRE DAMAGE DO NOT RUN THE POWER CORD BENEATH THE STOVE ...

Страница 36: ...mm thick ceramic glass Perform the procedure backwards after replacing When replacing the glass you should change the glass gasket to make sure you keep it sealed Never wash the glass with a product that may scratch it Use a specialized product available in the stores where wood stoves are sold Only wash when the stove is cold Under normal operating conditions the glass is designed to stay clean G...

Страница 37: ...at it will properly seat against the opening edges Tap it down with your poker to ensure proper seating Ashes should be placed in a metal container with a tightly fitting lid This closed container should be placed on a non combustible floor or on the ground well away from all combustible heat sensitive materials pending final disposal Cover the ash dump plug with the remaining ashes and continue o...

Страница 38: ...eosote makes an extremely hot fire which could be hazardous Your Drolet stove has been designed to reduce the amount of creosote produced Even so the chimney and any chimney connector should be inspected at least once every two months during the heating season to determine if a creosote build up has occurred If creosote has accumulated it should be removed to reduce the risk of a chimney fire Call...

Страница 39: ...placement part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations with respect to this warranty by refunding the wholesale price of any warranted but defe...