Drolet Austral Скачать руководство пользователя страница 27

 

26

DROLET LIMITED LIFETIME WARRANTY 

 

The  warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty 
covers brand new products only, which have not been altered, modified nor repaired since shipment from factory. Proof 
of purchase (dated bill of sale), model name and serial number must be supplied when making any warranty claim to your 
DROLET dealer.   

This warranty applies to normal residential use only.  Damages caused by misuse, abuse, improper installation, 
lack of maintenance, over firing, negligence, accident during transportation, power failures, downdrafts, or 
venting problems are not covered by this warranty. 

This warranty does not cover any scratch, corrosion, warping, or discoloration caused by over firing, abrasives or 
chemical cleaners. Any defect or damage caused by the use of unauthorized parts or others than original parts void this 
warranty. An authorized qualified technician must perform the installation in accordance with the instructions supplied 
with this product and all local and national building codes. Any service call related to an improper installation is not 
covered by this warranty. 
The manufacturer may require that defective products be returned or that digital pictures be provided to support the claim. 
Returned products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, 
the manufacturer will repair or replace such defect. Transportation fees to ship the product back to the purchaser will be 
paid by the manufacturer. Repair work covered by the warranty, executed at the purchaser’s domicile by an authorized 
qualified technician requires the prior approval of the manufacturer. Labour cost and repair work to the account of the 
manufacturer are based on predetermined rate schedule and must not exceed the wholesale price of the replacement part. 
All parts and labour costs covered by this warranty are limited according to the table below.   

The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the 
defect. The manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by refunding 
the wholesale price of any warranted but defective parts. The manufacturer shall in no event be responsible for any 
special, indirect, consequential damages of any nature, which are in excess of the original purchase price of the product. 
A one-time replacement limit applies to all parts benefiting from a lifetime coverage. This warranty applies to products 
purchased after March 1

st

 , 2009. 

 

DESCRIPTION 

WARRANTY APPLICATION 

PARTS LABOUR 

Combustion chamber (welds only) and castings. 

Lifetime 

3 years 

Stainless steel firebox components, secondary air tubes*, surrounds and heat 
shields, ash drawer, steel legs, pedestal, trims (aluminum extrusions), 
plating* (defective manufacture), and convector air-mate. 

5 years 

3 years 

Carbon steel firebox components, glass retainers, handle assembly, C-Cast 
baffle*, and vermiculite baffle*. 

3 years 

1 year 

Standard blowers, heat sensors, switches, rheostat, wiring, and other 
controls. 

2 years 

1 year 

Optional blowers, ceramic glass (thermal breakage only*), paint (peeling), 
gaskets, insulation, and ceramic fibre blankets. 

1 year 

n/a 

Firebrick n/a 

n/a 

*Pictures required 

 

Shall your unit or a components be defective, contact immediately your 

DROLET 

dealer. Prior to your call make sure 

you have the following information necessary to your warranty claim treatment: 

 

 

Your name, address and telephone number;  

 

Bill of sale and dealer’s name; 

 

Serial number and model name as indicated on the 
nameplate fixed to the back of your unit; 

 

Nature of the defect and any relevant information. 

 

Before shipping your unit or defective component to our plant, you must obtain from your DROLET dealer an 
Authorization Number. Any merchandise shipped to our plant without authorization will be refused 
automatically and returned to sender. 

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Содержание Austral

Страница 1: ...ONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVES Verified and tested following ULC S627 and UL 1482 Standards by Manufactured by STOVE BUILDER INTERNATIONAL INC 1700 L on Harmel Qu bec Qu bec...

Страница 2: ...RST FIRES 20 IGNITION 20 HEATING 21 RELOADING 22 CREOSOTE FORMATION AND NEED FOR REMOVAL 22 USE OF THE BYPASS DAMPER 23 ASH DISPOSAL 23 MAINTENANCE 25 GLASS 25 GASKETING 25 PAINT 25 DROLET LIMITED LIF...

Страница 3: ...may result To reduce the risk of fire follow the installation instructions Failure to follow instructions may result in property damage bodily injury or even death Consult your municipal building depa...

Страница 4: ...l Baltic Myriad Austral Legend L x P x H 23 x 26 x 31 603 x 673 x 800mm 23 x 26 x 30 603 x 673 x 768mm Combustion Chamber Width x Depth Volume W x D 18 x 20 464 x 514 mm 3 228 pi3 0 092 m3 Door Openin...

Страница 5: ...distance of approximately 18 inches on the flue pipe above the stove Flue gases should reach at least 350oF before you close the stove s primary air intake completely Operate your unit within the com...

Страница 6: ...in position Side Panels and Ash Lip Installation 1 Start by fixing the front part of the decorative side in the two clips welded on the sides of the fire box 2 Then fix the back of the decorative side...

Страница 7: ...6 AUSTRAL LEGEND AND MYRIAD Ash Pan Installation NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 8: ...tight fit To adjust Remove the lock pin spring pin by pulling and turning it using pliers wise grip Turn the handle counter clock wise one turn to increase pressure Re install the lock pin spring pin...

Страница 9: ...M OR SPACE HEATED SHALL BE PROVIDED WHEN REQUIRED POSITIONING THE STOVE It is very important to position the wood stove as close as possible to the chimney and in an area that will favour the most eff...

Страница 10: ...inches beyond each side Convert specification to R value k factor is given with a required thickness T in inches R 1 k x T C factor is given R 1 C Example If the floor protector is 4 brick with a C fa...

Страница 11: ...3 9 20 4 20 4 MYRIAD 7 6 23 24 16 17 13 7 12 7 34 9 35 9 27 9 28 9 Floor to ceiling height must be at least 7 84 in all cases The clearance between the flue pipe and a wall are valid only for vertical...

Страница 12: ...on the stove certification plate may be reduced as stated in the following table TYPE OF PROTECTION Reducing Clearances With Shielding Sides and Rear Back Top Sheet metal a minimum of 0 013 0 33 mm s...

Страница 13: ...is directly dependent on an adequate draught from your chimney The following recommendations may be useful for the installation of your chimney 1 Do not connect this unit to a chimney flue serving an...

Страница 14: ...t least 1 4 inch per foot with the upper end of the section toward the chimney To insure a good draught the total length of the coupling pipe should never exceed 8 to 10 24 to 3 04 m Except for cases...

Страница 15: ...BUILT CHIMNEY ROOF FLASHING 18 CLEARANCE WALL SUPPORT WALL RADIATION SHIELD RAIN CAP Wall installation CEILING SUPPORT RADIATION SHIELD Vertical installation NorthlineExpress com http www northlineexp...

Страница 16: ...15 MASONRY CHIMNEY Clay liner Thimble Clean out door NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 17: ...16 FACTORY BUILT THIMBLE NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 18: ...17 BRICK THIMBLE NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Страница 19: ...roll out when opened or back drafts occur whether or not there is combustion present 3 Opening a window slightly on a calm windless day alleviates any of the above symptoms 4 The house is equipped wit...

Страница 20: ...7 Pine 17 Bass 16 Fir 13 Data provided by Energy Mines and Resources Canada IT IS EXTREMELY IMPORTANT THAT YOU USE DRY WOOD ONLY IN YOUR WOOD STOVE The wood must have dried for 9 to 15 months such tha...

Страница 21: ...ion while curing the stove The odours could be smelled during the 3 or 4 first fires Never start your stove outside You will not be able to see if you are over heating The smoke resulting from the pai...

Страница 22: ...f you push on it until it stops the combustion air is reduced to a minimum Your DROLET stove burnt between 954 kg h et 2 556 kg h of wood during EPA testing Real operating conditions may give very dif...

Страница 23: ...the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire When burning wood the chimney...

Страница 24: ...or Close the bypass damper when you are finished reloading Never leave the bypass damper open under any condition unless you are building a fire or reloading the unit To open the by pass damper insert...

Страница 25: ...lly dispersed they should be retained in the close container until all cinders have thoroughly cooled CAUTIONS ASHES COULD CONTAIN HOT EMBERS EVEN AFTER TWO DAYS WITHOUT OPERATING THE STOVE THE ASH PA...

Страница 26: ...s where wood stoves are sold The glass should be washed only when cold GASKETING It is recommended that you change the door gasket which makes your stove door air tight once a year in order to insure...

Страница 27: ...ts covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defec...