background image

VacuMax

TM

 Suction Unit  

Instruction Guide

Medical Suction Device

Models No. :  
18610 VacuMax

TM

 Plus Suction Machine

18615 VacuMax

TM

 Go Portable Suction Machine 

This unit complies with EU EMC standard EN60601-1-2

Caution: Use this Aspirator Only for its intended use as described in this 
manual. Improper use or failure to do so could result in personal injury or 
property damage.  This device is to only be used by or on the prescription 
of a physician.

REV4.04.29.15

Содержание VacuMax 18610

Страница 1: ...Portable Suction Machine This unit complies with EU EMC standard EN60601 1 2 Caution Use this Aspirator Only for its intended use as described in this manual Improper use or failure to do so could re...

Страница 2: ...1 Introduction of Intended Use A This Medical Suction Device is intended for removal of fluids from the airway or respiratory system This appliance may also be employed in the removal of infections ma...

Страница 3: ...3 Product Structure A Visual appearance 18610 18615 B Assembly 18610 18615 AC Power Connection AC Power connection with Rechargeable Battery...

Страница 4: ...nit 2 Never operate the unit if it has any damaged parts including power cord and or if it has been dropped or submersed in water 3 The unit should not be used where flammable gas oxygen or aerosol sp...

Страница 5: ...Capacity 800cc 7 Dimensions 12 4in x 9 8in x 8 1in 315mm x 248mm x 207mm 8 Weight 4 4lbs 2 0 kgs 5 0lbs 2 3kgs 9 Life of Use 2 years 10 Operating Environment 50o F to 104o F 10o C to 40o C 30 to 75 R...

Страница 6: ...ct suction tubing and collection bottle for leaks cracks etc before each use B Turn on the device 1 Plug in the power cord 2 Turn on the power switch 3 Connect the suction tube to the device open the...

Страница 7: ...is not fully charged Will turn off when the unit is plugged in GREEN when fully charged Charging Light OFF when in use and operating on AC power RED while charging GREEN when fully charged and plugged...

Страница 8: ...commended after each treatment 1 Disconnect the tubes collection bottle the filter cover and the elbow Rinse the tubes collection bottle with water 2 Dry them with clean soft towel or let it air dry 3...

Страница 9: ...DCORD DC Power Cord for the 18615 1 ea 18615 BATTERY Replacement Rechargeable Battery for the VacuMax Go 18615 1 ea 18615 BAG Carry Bag for VacuMax 1 ea 18600 FILTER Hydrophobic Filter 3 bx 22330 800...

Страница 10: ...use of this product as outlined in the manual negligence accident or repairs by someone other than a Drive Medical Authorized Service Professional shall immediately void this warranty Drive Medical wi...

Страница 11: ...11 NOTES...

Страница 12: ...Drive Medical 99 Seaview Blvd Port Washington NY 11050 Toll Free 877 224 0946 www drivemedical com REV4 04 29 15...