Specification

Electrical Requirements  

115VAC/60Hz 

Power Consumption  

75W

Dimensions  

4.1” (105mm) High  

 

 

×5.7” (145mm) Wide  

 

 

× 7.9” (200mm) Deep

Weight  

1.6kg (3.53lbs)

Sound Pressure Level  

58dB(A)

Max. Comp. Pressure   

30 Psig or greater

Neb. Operating Pressure  

10~14 Psig

Liter Flow Range  

4 - 8 LPM

Particle Size  

Less Than 5 microns

Operating Temperature  

10

o

C ~ 40

o

C (50

o

F to 104

o

F)  

Operating Humidity  

Up to 95% non-condensing

Storage/Transport Temperature Range  

-20

o

C ~ 60

o

C (-4

o

F to 140

o

F)  

Storage/Transport Humidity  

Up to 95% non-condensing

(1).   Conditions may vary based on altitude above sea level, barometric pressure and  
 

temperature. Specification subjects to change without notice. 

(2).   This product complies with the following standards: C22.2 No 601.1-M90,  UL Std.  
 

No 2601-1 and IEC/EN 60601-1-1.  

(3).   For electromagnetic compatibility the standards are based as follow: CSA 601.1-2   
 

and IEC/EN 60601-1-2. 

(4).   Protection against electric shock is classified as 

Type II

(5).   Degree of protection against electric shock is classified as 

Type BF

(6).   Mode of operation belongs to continuous mode. 
(7).   Equipment not suitable for use in the presence of a flammable anesthetic mixture   
 

with air or with oxygen or nitrous oxide 

(8).   Degree of protection against ingress of water is rated as IPX0. 

Warning: 

 

To reduce the risk of burns, electrocution, fire or injury:

Warning: 

 

To reduce the risk of infection:

Содержание SportNeb 2

Страница 1: ...1 SportNeb 2 Compressor Nebulizer 3050 2 ...

Страница 2: ...2 Table of Contents IEC Symbols 3 Important Safeguards 4 Introduction 4 Specifications 5 Description 6 Operation Instructions 7 Cleaning 7 Maintenance 7 Warranty 8 ...

Страница 3: ...ways unplug the unit immediately after using 2 Do not use while bathing 3 Do not place or store the unit where it can fall or be pulled into a tub or sink 4 Do not place or drop into water or other liquid 5 Do not reach for a product that has fallen into water Unplug immediately Warning To reduce the risk of burns electrocution fire or injury 1 Electrical Shock Hazard do not remove the cabinet or ...

Страница 4: ...If you are using a reusable nebulizer kit cleaning of the nebulizer is recommended after each aerosol treatment Disinfecting is recommended once a day Since nebulizers vary in type and construction we recommend that you follow the cleaning instructions provided with the nebulizer If there is no cleaning instruction accompanying with the nebulizer follow the recommended cleaning procedures describe...

Страница 5: ... Conditions may vary based on altitude above sea level barometric pressure and temperature Specification subjects to change without notice 2 This product complies with the following standards C22 2 No 601 1 M90 UL Std No 2601 1 and IEC EN 60601 1 1 3 For electromagnetic compatibility the standards are based as follow CSA 601 1 2 and IEC EN 60601 1 2 4 Protection against electric shock is classifie...

Страница 6: ...6 1 Air Outlet Connector 6 Mouthpiece 11 Tubing 2 Filter Cap 7 Nebulizer Cap 3 Power Switch 8 Baffle 4 Power Cord 9 Nebulizer Chamber 5 Nebulizer T Piece 10 Air Inlet Connector Description ...

Страница 7: ...tween the teeth Inhale and exhale through the mouthpiece 10 If aerosol applied place the mask over the mouth and nose 1 Turn the power off and unplug from the wall outlet 2 Remove the tubing from the air inlet 3 Disassemble mouthpiece T piece nebulizer cap chamber and baffle and wash these items except the tubing in hot water with dish washing detergent Rinse these items thoroughly to remove the d...

Страница 8: ... with during the warranty period Normal maintenance items as outlined in this manual and disposable components are not covered by this warranty Shipping charges if any shall be paid by the purchaser NOTE There is no other express warranty Implied warranties including those of merchantability and fitness for a particular purpose are limited to the duration of the express limited warranty and to the...

Отзывы: