3) Next, you will want to remove the stator by placing your finger nail under
the small lip located on the narrow side of tear drop shaped stator and
pull out.
Stator
Pull-Tab
5) Once the stator is removed you can also remove the impeller (3 white-
bladed propeller) which is held in place magnetically. To remove the
impeller use a fingernail to get under the plastic blade and lift out.
6) Once the motor is disassembled you
can clean the parts with warm soapy
water. Use a cotton swab (Q-Tip) or
the Drinkwell
®
Cleaning Kit “Motor
Brush” to get into the motor cavity
and remove any build-up. For added
disinfecting and hard water removal,
clean the motor with a white vinegar
& water solution. Strengthen the
solution by increasing the amount of
white vinegar used. Be sure to rinse
thoroughly with fresh water.
7) Once the parts are clean and dry, you can reassemble the motor for use.
a) Replace the impeller.
b) Replace the stator.
c) Replace the intake plate.
1) Remove pump from the fountain as explained in the “Fountain and
Disassembly and Cleaning” section (Step 6).
2) Once the motor is out of the fountain, with your thumb and forefinger,
gently squeeze on either side of the intake plate and pull off. It may be
necessary to insert a fingernail into the seam of the intake plate to pry
it off.
PUMP MAINTENANCE