97377C (Rev. D - 8/01)

ESRC8*1E   ESRC13*1E, 2E,3E

PAGE 3

FIG. 3

Stream height is factory set at 35 PSI. If supply pressure varies greatly

from this, remove items 31 and 32 and adjust screw on item 34. Clockwise

adjustment will raise stream and counter-clockwise adjustment will lower

stream. For best adjustment, stream should hit basin approximately 6-1/2"

(165mm) from bubbler.

NOTE:

WHEN INSTALLING REPLACEMENT BUBBLER

AND PEDESTAL, TIGHTEN NUT (ITEM 12) ONLY

TO HOLD PARTS SNUG IN POSITION.

DO NOT OVER TIGHTEN.

BASIN

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

INSTALLATION OF COOLER

4) Hang the cooler on the hanger brackets.  Be certain the hanger brackets are engaged properly in the frame and wrapper.

5) Remove the access panel on the underside of the cooler and set it aside.

6) Connect water inlet line--See Note 4 of General Instructions.

7) Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the

trap.  Assemble the slip nut and gasket to the trap and tighten securely.

START UP

Also See General Instructions

8) Replace the front panel and secure by retightening all screws.

FIG. 4

10

11

12

8

9

WRAPPER

34

32

33

31

35

36

HANGER BRACKETS  AND TRAP INSTALLATION

1) Remove hanger brackets fastened to back of cooler by removing screws.

2) Mount the hanger brackets and trap as shown in Figure 2.

NOTE:

  Hanger brackets and trap 

MUST

 be supported securely.  Add fixture support carrier if wall will not provide adequate support.

IMPORTANT:

•    5-1/2 in. (140mm) dimension from wall to centerline of trap must be maintained for proper fit.

•    Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes.

3)  Install straight valve for 3/8 in. O.D. unplated copper tube.

All manuals and user guides at all-guides.com

Содержание ESRC8 1E Series

Страница 1: ... Installation Care Use Manual USES HFC 134A REFRIGERANT FIG 1 SEE FIG 3 SEE DETAIL ABOVE 26 6 2 43 8 See Fig 4 42 7 14 41 18 15 16 17 28 25 37 13 23 44 22 30 29 1 27 19 20 21 3 4 5 39 24 45 40 38 46 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...ONNE VENTILATION EN GARDANT 4 102mm MIN ENTRE LES ÉVENTS DE L ENCEINTE ET LE MUR F POWER CORD 1 1 2FEET 457mm LONG CABLE ELÉCTRICO DE 1 PIE 457 mm DE LARGO CORDON D ALIMENTATION 1 1 2 457mm LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 IN 38 mm OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COB...

Страница 3: ...t water inlet line See Note 4 of General Instructions 7 Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap Assemble the slip nut and gasket to the trap and tighten securely START UP Also See General Instructions 8 Replace the front panel and secure by retightening all screws FIG 4 10 11 12 8 9 WRAPPER...

Страница 4: ...Ferrule Tailpipe Tailpipe Gasket Angle Front Corner Bracket Basin Mounting Frame Back Bottom Bracket Front Locknut Fitting Elbow 1 4 Stem 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 ELKAY MANUFACTURING COMPANY 2222 CAMDEN COURT OAK BROOK IL PRINTED IN U S A 220 240V 50Hz 31506C 31430C 35763C 31024C 66552C Power Co...