background image

97445C (Rev. C - 11/00)

EHOA8*1E

PAGE 3

SENSOR RANGE ADJUSTMENT

:  The electronic sensor used in this cooler is factory pre-set for a "visual" range of 36

     inches (914 mm).  If actual range varies greatly from this or a different setting is desired, follow the range adjustment

     procedure below:

A.  Remove front panel of cooler.

B.  Using a small tip screwdriver, rotate range adjustment screw clockwise to increase range and counterclockwise to

     decrease range (See Fig. 3).

     CAUTION

:  Complete range of sensor (24-28 inches/610-711mm) is only one turn of the adjusting screw.

C.  Replace front panel.

SENSOR CONTROL

:  If sensor fails to operate valve mechanism or operates erratically, check the following.

A.  Ensure there are no obstructions within a 40 inch (1016mm) radius in front of cooler.

B.  Check wire connections at the solenoid valve and sensor.  

CAUTION

:  Make sure unit is unplugged before checking any

     wiring.

C.  Ensure proper operation of solenoid valve.  If there is an audible clicking sound yet no water flows, look for an obstruction

     in the valve itself or elsewhere in the water supply line.

13

14

10

6

FIG. 3

HANGER BRACKETS & TRAP

INSTALLATION

1

) Remove hanger brackets fastened to back of cooler by

removing one (1) screw.

2) Mount the hanger brackets and trap as shown in Figure 2.

NOTE:

  Hanger Brackets MUST be supported securely.  Add

fixture support carrier if wall will not provide adequate

support.

IMPORTANT:

Ÿ

Anchor hanger securely to wall using all six (6) 1/4 in. dia.

mounting holes.

3) Install straight valve for 3/8" O.D. unplated copper tube.

INSTALLATION OF COOLER

4) Hang the cooler on the hanger brackets.  Be certain the

hanger brackets are engaged properly in the slots on the

cooler back as shown in Figure 2.

5) Loosen the two (2) screws holding the lower front panel at

the bottom of cooler base.  Remove the front panel and

set aside.

6) Connect water inlet line--See Note 4 of General Instruc-

tions.

7) Remove the slip nut and gasket from the trap and install

them on the cooler waste line making sure that the end of

the waste line fits into the trap.  Assemble the slip nut and

gasket to the trap and tighten securely.

START UP

Also See General Instructions

8) Stream height is factory set at 35 PSI.  If supply

pressure varies greatly from this, adjust screw, ac-

cessible by removing front panel (Item 7, Fig. 3).  CW

adjustment will raise stream and CCW adjustment

will lower stream.  For best adjustment, stream should

hit basin approximately 6-1/2” (165mm) from bub-

bler.

9) Replace the front panel and secure by retightening

two (2) screws.

ITEM NO.

PART NO.

Panel-Bottom Dispenser

Bracket-Valve Mounting

Sensor-Clear (115V)

Sensor-Clear (230V)

Solenoid Valve (115V)

Solenoid Valve (230V)

Panel-Right Side

Panel-Left Side

Panel-Front

Elbow 1/4 Stem x 1/4 O.D.

Fitting 1/4 NPTF x 1/4 O.D.

Nut-Regulator

Screw-#6-32 x 1/2" Lg. PHMS

Screw-#10 x 1/2" Lg. PHSM

Hex Nut

Screw-#8 x 5/8" Lg. Torx/Slot

Holder-Regulator

Regulator

Screw-#10 x 1/2" Lg. HHSM

26588C

26866C

31516C

35783C

31272C

35784C

See Color Table

See Color Table

See Color Table

70817C

75507C

56082C

70644C

75497C

40045C

70864C

50986C

61314C

70002C

Item No. 5

Part No.

COLOR TABLE

Gray Beige

Almond

Stainless Stl

Sandalwood

Granite

26635C

26636C

26637C

26638C

26641C

26605C

26606C

26607C

26608C

26611C

26731C

26732C

26733C

26734C

26737C

PANEL

COLOR

Item No. 6

Part No.

Item No. 7

Part No.

11

2

9

4

12

1

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

DESCRIPTION

NOTE:  WATER FLOW DIRECTON

RANGE ADJUSTMENT SCREW

3

16

15

14

7

14

5

9 17

8

Содержание EHOA8*1E

Страница 1: ...00 EHOA8 1E PAGE 1 With FLEXI GUARD Installation Care Use Manual USES HFC 134A REFRIGERANT FIG 1 19 SEE FIG 4 46 SEE FIG 3 27 47 43 44 45 51 34 42 52 39 40 41 50 26 51 25 53 21 53 35 36 37 48 20 18 33 22 23 24 38 49 54 ...

Страница 2: ...EL ORIFICIO 1 1 4 32mm SOBRE LA CORONA HAUTEUR DE L ORIFICE 1 1 4 32mm AUDESSUS DU REBORD LEGEND LEYENDA LÉGENDE A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 IN 38mm OUT FROM WALL SHUT OFF BY OTHERS SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3 8 DE DIÁM EXT A 1 1 2 38mm FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERC...

Страница 3: ...are engaged properly in the slots on the cooler back as shown in Figure 2 5 Loosen the two 2 screws holding the lower front panel at the bottom of cooler base Remove the front panel and set aside 6 Connect water inlet line See Note 4 of General Instruc tions 7 Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into...

Страница 4: ...Angle Bracket Corner Bracket Front Support Bracket Basin Mtg Poly Tubing 48 Cut To Length 27097C See Color Table 31483C 27095C 30699C 70018C 31490C 70009C 50186C 70241C 51349C 40322C 50168C 50934C 70012C 62152C 66202C 50144C 70184C 70150C 35960C 35958C 35768C 35959C 66501C 40572C 40575C 50074C 21222C 70208C 31513C 66505C 55996C 27093C 27094C 27096C 56092C PANEL COLOR DESCRIPTION INCLUDES RELAY OVE...

Отзывы: