background image

SKU 67024 

For technical questions, please call 1-800-444-3353. 

Page 12

LImItED 90 DaY WaRRantY

Harbor Freight Tools Co. makes every effort to assure that its products meet high 

quality and durability standards, and warrants to the original purchaser that this prod-

uct is free from defects in materials and workmanship for the period of 90 days from 

the date of purchase. This warranty does not apply to damage due directly or indirectly, 

to misuse, abuse, negligence or accidents, repairs or alterations outside our facilities, 

criminal activity, improper installation, normal wear and tear, or to lack of maintenance. 

We shall in no event be liable for death, injuries to persons or property, or for incidental, 

contingent, special or consequential damages arising from the use of our product. Some 

states do not allow the exclusion or limitation of incidental or consequential damages, so 

the above limitation of exclusion may not apply to you. THIS WARRANTY IS ExPRESS-

LY IN LIEU OF ALL OTHER WARRANTIES, ExPRESS OR IMPLIED, INCLUDINg THE 

WARRANTIES OF MERCHANTAbILITY AND FITNESS.

To take advantage of this warranty, the product or part must be returned to us with 

transportation charges prepaid. Proof of purchase date and an explanation of the com-

plaint must accompany the merchandise. If our inspection verifies the defect, we will ei

-

ther repair or replace the product at our election or we may elect to refund the purchase 

price if we cannot readily and quickly provide you with a replacement. We will return re-

paired products at our expense, but if we determine there is no defect, or that the defect 

resulted from causes not within the scope of our warranty, then you must bear the cost 

of returning the product.

This warranty gives you specific legal rights and you may also have other rights 

which vary from state to state.

3491 Mission Oaks Blvd.  •  PO Box 6009  •  Camarillo, CA 93011  •  (800) 444-3353

Содержание 67024

Страница 1: ...do so can result in serious injury Save this manual Copyright 2009 by Harbor Freight Tools All rights reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual may not be drawn proportionally Due to continuing improvements actual product may differ slightly from t...

Страница 2: ...oided could result in death or serious injury CAUTION used with the safety alert symbol indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTICE is used to address practices not related to personal injury CAUTION without the safety alert symbol is used to address practices not related to personal injury IMPORTANT SAFETY INSTRUCTIONS Instructions Pertaini...

Страница 3: ... on invites accidents Remove any adjusting key or d wrench before turning the power tool on A wrench or a key left at tached to a rotating part of the power tool may result in personal injury Do not overreach Keep proper e footing and balance at all times This enables better control of the power tool in unexpected situations Dress properly Do not wear f loose clothing or jewelry Keep your hair clo...

Страница 4: ... risk of injury and fire When battery pack is not in use c keep it away from other metal ob jects like paper clips coins keys nails screws or other small metal objects that can make a connec tion from one terminal to another Shorting the battery terminals to gether may cause burns or a fire Under abusive conditions liquid d may be ejected from the battery avoid contact If contact acciden tally occ...

Страница 5: ...g alone Do not use with power switch locked on Properly maintain and inspect to avoid electrical shock WARNING Some dust created by 10 power sanding sawing grinding drill ing and other construction activities contains chemicals known to the State of California to cause cancer birth defects or other reproductive harm Some examples of these chemicals are Lead from lead based paints Crystalline silic...

Страница 6: ...vibration such as tingling numbness and white or blue fingers seek medical advice as soon as pos sible Do not smoke during use Nico 2 tine reduces the blood supply to the hands and fingers increasing the risk of vibration related injury Wear suitable gloves to reduce the 3 vibration effects on the user Use tools with the lowest vibration 4 when there is a choice Include vibration free periods each...

Страница 7: ...ols at 1 800 444 3353 Instructions for putting into use Read the entire Important Safety Information section at the beginning of this manual including all text under subheadings therein before set up or use of this product To prevent serious injury from accidental operation Turn Tool off and remove Battery Pack before assembling or making any adjustments to the tool Note For additional information...

Страница 8: ... bit holder adapters Do not use larger size drill bits as damage to gears motor may result Always use a drill bit that is designed for specific drilling job Slide Direction Selector 38 to its 4 mid position While holding ring behind collar of Chuck 2 with one hand rotate collar counterclockwise to open jaws Insert shank of drill bit or hex shank of bit adapter into Chuck Turn collar clockwise to h...

Страница 9: ...r condition that may affect its safe operation After Use 2 wipe external surfaces of the tool with clean cloth When storing always store Impact 3 Wrench in clean dry and safe loca tion out of reach of children Troubleshooting Problem Possible Causes Likely Solutions Tool will not start Battery not charged Charge Battery Hammer function not available Selector Ring in drilling position Slide Selecto...

Страница 10: ...Battery pack 1 41 Right Housing 1 42 Tapping screw ST2 9x16 8 43 Contact plate 1 44 Contact strip 2 45 Cylindrical Vial Lever 1 46 Circular Vial Lever 1 Parts List PLEASE READ THE FOLLOWING CAREFULLY The manufacturer and or distributor has provided the parts list and assembly diagram in this manual as a reference tool only Neither the manufacturer or distributor makes any representation or warrant...

Страница 11: ...t s Serial Number Here Note If product has no serial number record month and year of purchase instead Note Some parts are listed and shown for illustration purposes only and are not avail able individually as replacement parts Please note Cylindrical Vial Lever 45 and Circular Vial Lever 46 not shown ...

Страница 12: ...cidental or consequential damages so the above limitation of exclusion may not apply to you This warranty is express ly in lieu of all other warranties express or implied including the warranties of merchantability and fitness To take advantage of this warranty the product or part must be returned to us with transportation charges prepaid Proof of purchase date and an explanation of the com plaint...

Отзывы: