User Manual
BUILT-IN GAS STOVE |
GENOVA 90
10
are equipped with outside ventilation ducts. Although the adjacent rooms are not shared
areas, the rooms, but the risk of fire is hidden (Fig. 4).
Examples of ventilation holes Enlarge the ventilation slot between the window and the floor
for combustion air.
c) Intensive and prolonged operation of the gas plate that needs to intensify ventilation,
e.g. open windows or increase the power of the air intake system (if present).
d) Liquefied petroleum gases are heavier than air, therefore, deposit them down. Rooms in
which LPG tanks are installed must be equipped with outward ventilation to prevent gas
leaks.
Therefore, LPG tanks that are empty or partially filled should not be installed or stored in
rooms or spaces below ground level (warehouses, etc.). It is a good idea to keep only
the tank currently operating in the room and make sure it is not closed to the heating
source (ovens, fireplaces, stoves, etc.).
Installation of the built-in gas stove
The gas plates are designed with a degree of protection against excessive heating, the device
can be installed next to the cabinets and the height must not exceed the plate.
For proper installation, the following precautions must be followed:
a) The plate can be located in a kitchen, a dining room or in a bed / living room, but
not in a bathroom or shower.
b) The furniture standing near the unit, is taller than the work tables, must be placed
at least 110 mm away from the edge of the table.
c) The cabinets should be placed near the hood at a height of at least 420 mm (Fig.
5).