Low voltage-fused-switch disconnector system 403                                                                 Introduction 

 
B843

 4 / 16

1       Introduction

 

 
Thank you for choosing one of our products. We hope it gives you many hours of successful and pro-
blem-free operation. 

The low-voltage-fused switch disconnector system 403

 

has been specially designed and manufactu-

red to meet your requirements. 
 
Do you have any questions you would like to ask us? We look forward to hearing from you.

1.1     Notes on this manual

 

 

1.1.1   General note

 

 
This operating and maintenance manual contains all information and descriptions required to operate 
the Earthing switch. This document was created with the utmost care. Any suggestions or comments 
would be gratefully received. 
To make the instructions in this manual easier to follow, the descriptions are accompanied by figures 
and schematic diagrams of the switching device or its assemblies. 
 

 

1.1.2    Use of symbols / legend

 

 
The following symbols are used in this manual in addition to the warning notices outlined in the chapter 
Safety: 
 

                   

WARNING:

Warns of danger to people. Failure to comply with the warning indicated 

                   

by this symbol will result in severe injuries. 

                   

 

                   

Warns against damage to property and personal injury caused by mechanical com

                   

ponents. Failure to comply with the indications marked with this symbol will result in 

                   

serious injuries. 

 

                   

Warns against damage to property and personal injury caused by electrical voltage or 

                    

arc. Failure to comply with the indications marked with this symbol will result in serious 

                    

injuries. 

 

                   

Caution:

 Failure to comply with the warning indicated by this symbol could result in 

                   

injuries. 

 

                   

Attention:

 Warns of possible material damageor malfunctions. Technical information 

                   

requiring particular attention. 

 

        

Содержание B843

Страница 1: ...HNE GMBH D 85366 MOOSBURG PHONE 49 87 61 6 81 0 FAX 49 87 61 68 11 37 http www driescher de infoservice driescher de Mounting and operating instructions for DRIESCHER Low voltage fused switch disconne...

Страница 2: ...ntended use guarantee 8 2 2 Personnel selection and necessary qualifications 8 2 3 Organisational safety 8 2 4 Dangers caused by the switching device 9 2 4 1 Danger due to moving parts 9 2 4 2 Danger...

Страница 3: ...al 16 Low voltage fused switch disconnector system 403 B843 3 16 CE marking The DRIESCHER low voltage products are subject to the CE marking requirement in connec tion with the Low Voltage Directive 2...

Страница 4: ...he descriptions are accompanied by figures and schematic diagrams of the switching device or its assemblies 1 1 2 Use of symbols legend The following symbols are used in this manual in addition to the...

Страница 5: ...azards for people and goods when handling electrical energy the expert handling of the equipment and compli ance with the applicable regulations is generally required Installation and maintenance work...

Страница 6: ...ing cover M Inspection holes N Flat spring O Busbar contact P Mounting brackets for frame mounting Q Slider 3 pole R Slider 3 pole with operating handle S Terminal screw M12 caulked 6 16 Low voltage f...

Страница 7: ...ng handle switchable Slider B with recessed grip above and down with inserted low voltage high rupturing capacity fuse C 1 pole switchable 3 pole switchable with operating handle 3 pole switchable Pic...

Страница 8: ...st be at least 18 years of age have received sufficient training for the relevant tasks be familiar and comply with the current valid rules and safety regulations The owner must ensure that only autho...

Страница 9: ...vicinity are supplied with dangerous current Touching these parts poses a risk of personal injury or material damage In the case of a fault arc extreme hazards arise high thermal energy pressure wave...

Страница 10: ...ing may only be carried out by specially trained specialists Please refer to the Safety Tools instructions for use Order No 3 81301043 Insulating socket wrench scope of delievery Pic 4 10 16 Top side...

Страница 11: ...system 403 Pic 5 and 6 Tightening torque 30 Nm 4 Connect the cable see chapter 3 3 2 page 13 5 Integrate the cable insulating cover L Pic 7 at the cable feeder Pic 5 403 system mounting situationon a...

Страница 12: ...on system 403 Pic 9 3 Ingerate the cable insulating cover L Pic 7 on system 403 to prevent unintentional contact 4 Put system 403 on the frame 5 Fix system 403 Pic 9 10 or 11 Tightening torque 75 Nm 6...

Страница 13: ...isted or bent under any circumstances The caulked connection screws S must not be removed Furthermore a connection with V direct connection terminals or flat direct connection termi nals is possible f...

Страница 14: ...Removal low voltage fused switch disconnector system 403 For the disassembly of the low voltage fused switch disconnector system 403 the steps mentioned on page 11 and 12 assembly must be carried out...

Страница 15: ...ss actuate quickly upwards the slider is now back in Stand by position When actuating use the recessed grip at the top and bottom of the sli der For slider 3 pole with actuating handle use both hands...

Страница 16: ...g to EN 60947 3 AC 22B AC 22B AC 22B Degree of pollution 3 3 3 Rated reduction factor RDF 1 0 1 0 1 0 Temperature range 25 up to 55 C Site altitude max 2000 m over NHN Relative humidity maximum daily...

Отзывы: