Dri-Eaz TurboDryer Sahara Pro X3 Скачать руководство пользователя страница 2

WARNING

ELECTRIC SHOCK HAZARD

Keep motor and electrical parts

dry.
Do not operate in standing water
Do not expose to rain, water or
snow.

Do not get the exterior. motor or wir-

ing wet.

Do not dean with wet objects, i.e.,
power washers, soap and water, etc.

If motor or electrical parts become

wet, allow them to dry completely

before using.

Read and understand manual be-

fore operating

WARNING

FIRE HAZARD

Keep air intakes clear. Reduced

airflow can cause motor to overheat.

Clean any lint or other material

from the screens before each use

Do not operate near draperies or

other material that could block the
air intakes.

Clean dust and dirt from motor

using a vacuum or compressed air.
Do not use or store where flamma-

ble vapors like gasoline, solvents, or

thinners are present.

Do not use near open flames, or

heat sources.

Read and understand manual be-

fore operating.

READ AND SAVE THESE INSTRUCTIONS

07-01537 Copyiight 2006 Dri-Eaz Products, Inc.

COOL AND VENTILATE

Place the airmover on a flat surface, and direct the air from cooler

areas (including the outdoors) into a warm room.

TURBODRYER STORAGE

Stackable

Units can be stacked (up to 3) on their sides

for storage.

NOTICE

Stacking feature is not secure enough to

be used during transport.

I A 

WARNINO 

N

ea

l

 

I

Always disconnect the TurboDryer from its

power source 

before 

performing any mainte-

nance or cleaning.

Preventive Maintenance

Routine maintenance can significantly increase the life of your Tur-
boDryer ft also promotes efficient operation. The applications and

amount of use by owners vary, so the recommendations listed below

are for average-to-high-volume use in water damage. Constant opera-
tion or use in other environments 

may 

require additional maintenance.

Contact Dri-Eaz for more information.

NOTE: Do not oil motor bearings: they are permanently oiled.

BEFORE EACH USE:

Inspect power cord for cuts, fraying or damage; do not use if dam-

aged

Remove lint or obstructions from the grills using a vacuum or com-

pressed air

Inspect exterior components (switch, knob, etc ) for damage.

QUARTERLY (OR AS NEEDED):

Clean the exterior with a household all-purpose spray cleaner.

Spray the rag. then apply to the surface.

To renew shine on the plastic. use a vinyl cleaner.

Remove grill and blower, then blow off internal components with

compressed air.

ANNUALLY:

Inspect 

components and internal Wring for discoloration, loose

con-

nections, or fraying.

Содержание TurboDryer Sahara Pro X3

Страница 1: ...rs to prevent them from blowing shut I A WARNING I Do not move or carry a TurboDryer while under operation When the unit is in motion the powerful airflow is hard to control and can produce rapid and unpredictable movement Do not allow children to play with or around TurboDryers If they lift or get a unit off balance the powerful airflow can cause the TurboDryer to move rapidly risking injury OPER...

Страница 2: ...RAGE Stackable Units can be stacked up to 3 on their sides for storage NOTICE Stacking feature is not secure enough to be used during transport IA WARNINO N eal I Always disconnect the TurboDryer from its power source before performing any mainte nance or cleaning Preventive Maintenance Routine maintenance can significantly increase the life of your Tur boDryer ft also promotes efficient operation...

Страница 3: ... when replac ing wheel Pull the blower wheel out of the unit To remov e control panel arid motor Rotate the unit onto its side so that the controls are facing up 5 Unscrew 2 screws securing cord guard 2 Phillips screwdriver 6 Remove cord guard 7 Remove 4 motor mount bolts with 3 8 nutdriver 8 Pull motor assembly out of the housing To reassemble unit Follow the steps above in reverse order starting...

Страница 4: ...ight 18 8 48 cm Speeds Three Weight 27 lbs Width 17 0 43 cm Switch Type Rotary Positions 3 U 45 90 Depth 18 3 47 cm Rated Airflow 2700 CFM 4587 CMH Carpet Clamp Available as ac cessory Static Pressure 1 36 3 5 cm Tested Airflow 1013 CFM 1718 CMH Circuit Pro tection Circuit Breaker GFC1 Motor 0 33 HP Overheating Cut offs Dual Thermal Protectors Safety Marks UL C UL Power 4 amps Cord Length 25 ft 7 ...

Отзывы: