SETUP AND OPERATIONS 

Positioning the Dehumidifier 

For best results, operate your dehumidifier in an en-
closed area. Close all doors and windows that open 
to the outside to maximize water removal efficiency. 
Place your dehumidifier away from any obstructions 
that could block airflow into and out of the unit. Duct 
reactivation outlet outdoors through window adapter 
or dryer vent.  

 

Plug in electrical cords 

Always plug the cords firmly into the sockets in 
the top compartment first, then into the wall out-
lets. Ensure that the cords are routed properly 
through the cord cutout notch before closing the 
storage compartment lid.  

NOTICE:

 The power cords of the DriTec must be 

plugged into separate GFCI-protected 120V outlets 
rated for at least 15A.  

NOTICE:

 Connect to two separate 15A circuits ON-

LY. A bright green light on the front of the unit indi-
cates correct connections. No light will show when 
using only one cord or if both power cords are 
plugged into the same power circuit. 

If a second circuit is not available, the unit may 
be operated on a single power cord. Plug into 
Circuit 1. Note that the unit will operate at 50% of 
the rated performance when using a single pow-
er cord.  

Startup display and normal display modes 

When unit is first plugged in, the control panel dis-
play will briefly cycle through a series of readouts. 
This is part of the unit’s self-diagnosis procedure and 
no user intervention is required. 

 

 
 
 
 
 
 

NOTICE 

Condensation may collect in the reactivation duct during opera-
tion. Do not allow water to run back into the unit. This could 
cause a shock hazard or damage to the unit. 

F533-115V 

Dri-Eaz Products, Inc. 

Содержание F533-115V

Страница 1: ...ult in a risk of electric shock Check with a qualified electrician or service person if you are in doubt as to whether the outlets are properly grounded Do not modify the plugs provided with the appli...

Страница 2: ...ert duct ring into circular slot and rotate clockwise until snug Parts Identification Air filter Power sockets inside compartment Stor age for power cords react ducting Air inlet Reactivation Air Outl...

Страница 3: ...ng Install the 4 offset screws provided Note the correct placement of the washer and spacer on the screw Do not overtighten Optional Install Air Inlet Duct Ring Attach to inlet with the thumbscrews pr...

Страница 4: ...outlets rated for at least 15A NOTICE Connect to two separate 15A circuits ON LY A bright green light on the front of the unit indi cates correct connections No light will show when using only one cor...

Страница 5: ...Temperatures inside React Out ducting can reach 150 F 66 C Use only heat rated ducting as provided React ducting should always be ducted out of doors Process Outlet Ducting Optional The process out ai...

Страница 6: ...isplay normally reads PLEASE WAIT WARMING UP Once the unit completes the warm up procedure the display shows UNIT ON XXX HRS and cycles between INLET XXX F and INLET XX RH DISPLAY MENU Cycles through...

Страница 7: ...NT 00 A For information only HUMIDISTATMODE OFF HUMIDISTATMODE ON Press to display ON or OFF Press to accept HUMIDISTAT SETPOINT 00 Press to cycle through 5 60 at 5 increments Press to accept RH MIN S...

Страница 8: ...Ducting Options F533 115V 8 Dri Eaz Products Inc...

Страница 9: ...minants clean thoroughly and disinfect before reuse Tools and supplies required 3 mm Allen wrench and or bit and cordless drill Clean cloths Vacuum cleaner with soft brush tool and or a high pressure...

Страница 10: ...T The inlet temp RH sensor cable is attached to the interior of the panel and must be detached before setting the panel aside To re move the cable first unclip the plug and then slide the cable down a...

Страница 11: ...ower Check that the impeller rotates freely Vacuum or wipe clean all surfaces Inspect rotor belt If belt has cracks or excessive wear contact your Dri Eaz distributor for a replace ment F533 115V 11 D...

Страница 12: ...n dry cloth Do not apply water or cleaning solutions of any kind Take care not to damage electronic sensors and wires Reattach side panel Reattach sensor cable inside panel Thread the cable up through...

Страница 13: ...em The electronic control panel may require replace ment Contact service Air Inlet temperature set point for cycling air conditioner to control temperature Check AC power for low voltage ER2 CONTACT S...

Страница 14: ...ing as much as possible remove any blockages React Duct length should not exceed 20 ft 6 m Unit does not operate Unit not switched on No power to machine Switch unit on Check power cord connections at...

Отзывы: