Dri-Eaz F413-230V EU Скачать руководство пользователя страница 1

07-01899G F413-230V EU/UK 

Legend Brands Holdings Ltd. 

Owner’s Manual 

Revolution LGR Dehumidifier 

Model F413-230V EU/UK 

LEGEND BRANDS HOLDINGS LTD.

 

22 Plover Close, Interchange Park, Newport Pagnell, MK16 9PS 

Tel: +44 (0)1908-611-211 Fax: +44 (0)1908-611-363 

www.legendbrandseurope.com

 

The Dri-Eaz

®

 Revolution LGR Dehumidifier reduces humidity in enclosed environments by removing wa-

ter vapor from the air. The Revolution is ideal for water damage restoration, structural drying, construc-

tion, and many other applications requiring temporary, high-performance dehumidification.  

Patents: http://www.LBpatents.com 

O R I G I N A L   I N S T R U C T I O N S

 

 

 
 
 
 
 
 
 
 
WARNING! Do not alter or modify your dehumidifier 

in any way. Use only replacement parts authorized 

by Dri-Eaz Products, Inc. Modifications or use of 

unapproved parts could create a hazard and will 

void your warranty. Contact your authorized 

distributor for assistance. 
WARNING! Electric shock hazard, rotating fan haz-

ard and hot surface hazards.  

  Inspect the power cord before use. If cord is dam-

aged, do not use. Always grasp the plug (not the 

cord) to unplug. 

  Must be earthed. Insert three-prong plug on power 

cord into a matching electrically earthed outlet. Do 

not use adapter. Never cut off third prong. Do not 

use an extension cord.  

  The unit must be operated on a 230V/50 Hz circuit 

protected by a Residual Current Device (RCD) de-

vice.  

  Keep motor and wiring dry. 

  Always unplug unit before cleaning or servicing. 

  Do not attempt to repair the unit. For service, contact 

your local distributor. 

FIRE HAZARD 

  Keep away from open flames and heat sources. 

 Do not use or store where vapors from gasoline, sol-

vents, thinners or other flammable materials may be 

present. 

BEFORE YOU BEGIN 

Warranty registration 

Warranty registration procedures vary by country/mar-

ket. Contact your local distributor for assistance. Regis-

tration allows us to better assist you with using, main-

taining or servicing your equipment and to contact you in 

case we have important safety information concerning 

your Dri-Eaz product. If you determine service is re-

quired, have your equipment model, serial number and 

original proof of purchase available and ask for assis-

tance with obtaining a return material authorization 

(RMA). 

 

GROUNDING INSTRUCTIONS 

This unit’s plug must be inserted into an appropriate out-

let that is properly installed and grounded in accordance 

with all local codes and ordinances. 

WARNING! Improper connection of the equipment-

grounding conductor can result in a risk of electric 

shock. Check with a qualified electrician or service 

person if you are in doubt as to whether the outlets 

are properly grounded. Do not modify the plugs pro-

vided with the appliance – if the plugs do not fit the 

outlets, have proper outlets installed by a qualified 

electrician.  

This equipment is for use on circuits with a nominal rat-

ing of no more than 230V.  

Handle the unit carefully 

Always operate the unit on a stable, level surface. Do 

not drop, throw, or place where it could fall. Rough treat-

ment can damage the unit, and may create a hazardous 

condition or void the warranty. 
This unit intended for household and commercial use.  

WARNING

 

Содержание F413-230V EU

Страница 1: ...r the unit For service contact your local distributor FIRE HAZARD Keep away from open flames and heat sources Do not use or store where vapors from gasoline sol vents thinners or other flammable mater...

Страница 2: ...ave any part of the hose coiled and do not place the end of the hose higher than 6 m above the bottom of the unit Also check for kinks or other obstructions that might restrict the flow of water Obstr...

Страница 3: ...and the machine will begin operation immedi ately DISPLAY MENU Press to cycle through the display of additional dehumidifier conditions and User Settings To return to the main menu press the ON OFF k...

Страница 4: ...ormation only 3 GRAIN DPR XX GPP Unit displays GPP if set to Fahrenheit or g kg if set to Celsius To change this setting see menu item 9 4 FILTER CHECKED XXX HRS 4 FILTER CHECKED 0 HRS Press to clear...

Страница 5: ...ces falls into the sump area 3 Press the PURGE key When the purge cycle is complete turn the unit off 4 Remove the external drain hose drain it carefully coil it and return it to the storage tray on t...

Страница 6: ...rformance and causing the unit to over heat Use a vacuum cleaner with a brush tool and a soft cloth to remove any debris Take care not to damage any interior components To maintain appearance wipe int...

Страница 7: ...e HUMIDISTAT INLET XXX F XX First line indicates unit is in humidistat mode Second line Toggles between inlet temperature and in let RH every 2 seconds None LOW TEMP INLET XXX F XX Unit shuts off if i...

Страница 8: ...ONNECT or ER4 OUTLET SENSOR CONNECT Temp sensor is open missing or shorted Check that temp sensors are installed cor rectly on control panel If error persists contact service ER5 SENSOR CONNECTION ON...

Страница 9: ...ity level with hygrometer Increase room temperature Check filter Replace as necessary Check coils Clean as necessary If the problem you are experiencing is not listed here call your local distributor...