Dri-Eaz Dri-X Airchanger Скачать руководство пользователя страница 3

COPYRIGHT 

 DRI-EAZ PRODUCTS, INC. 1997

3

Keep Children Away

The Dri-X Airchanger is not a toy. Do not al-

low children to play with or around the unit. Be
sure that the unit is inaccessible to children when
left unattended. Children can hurt themselves or
others by playing with or around a unit. Secure all
rooms and buildings in which a unit is left unat-
tended while running.

Secure Unit During Transport

When transporting in a vehicle, secure the Dri-

X to prevent sliding and possible damage to the
unit or injury to vehicle occupants.

Don’t Modify Unit

Never modify the motor or wiring of the Dri-X.

Keep Air Intakes Unobstructed

Operate the Dri-X away from draperies and

other materials that may come in contact with its
air intakes. Always use a clean air filter.

Maintenance or Repair

Do not attempt to disassemble or repair the Dri-

X Airchanger if you are not qualified to do so.
Normal maintenance operations and trouble-
shooting solutions can be handled by the techni-
cian in the field. More complex problems should
be handled by an authorized service technician.
See the Troubleshooting section. For information
about authorized repair and maintenance, call Dri-
Eaz at (360) 757-7776.

Danger

Do not attempt to service or clean the Dri-X
Airchanger while it is plugged into an electrical
outlet. It is dangerous for an unqualified individual
to attempt to disassemble or repair the unit.

LIMITED 1-YEAR WARRANTY

Limited Warranty:

 Dri-Eaz promises to the

original purchaser to replace, at no charge, any
part of the Dri-X Airchanger that proves to be de-
fective in workmanship or materials for a period
of one (1) year from date of purchase. During this
period the customer is responsible for all freight
and labor costs. After one year, the customer is
responsible for all replacement parts, labor and
freight costs to and from the service center.

To receive warranty parts:

 All replacement

parts must be pre-authorized through our service
center. Please direct questions on the warranty to
an authorized distributor or Dri-Eaz Products, Inc.

Limitations:

 

This warranty shall not extend to

any products showing effects of misuse, disassem-
bly, alteration, lack of proper maintenance, corro-
sive chemicals, improper voltage, accident dam-
age, unauthorized repairs, use of other than
authorized parts and materials, fire, flood, normal
wear or any other causes beyond Dri-Eaz Prod-
ucts' control. The warranty obligation extends only
to the replacement of parts found, upon Dri-Eaz
Products' examination, to be defective. The fore-
going constitutes the entire warranty and no other
warranty, liability, contingency or responsibility,
direct, indirect, consequential or in any way con-
nected with the sale or operation of equipment
products is expressed or implied.

OPERATING PRINCIPLES

The Dri-X Airchanger performs two functions

that are useful for restorative drying and other ap-
plications.

First, it lowers the humidity to dehumidify the

air. Ample dehumidification is a necessity when
drying wet buildings and materials.

Major Parts and Airflow Pattern

Drip
Tray

Fresh Air
f rom Out d o

Humid Air
t o Outdoor

Humid  Air
f ro m Room

Fresh Air
t o Room

Energy
Exchange
Co re

Filt ers

One airstream carries humidity and contamination harmlessly to
the outdoors. The other airstream brings fresh, clean air from
outdoors to replace it. Heating/cooling energy is saved by the
Energy Exchange Core. Both airstreams are cleaned by filters
before entering the Core. Moisture that may condense is caught
in the drip tray and pumped to a drain.

Second, the Dri-X improves IAQ or indoor air

quality. It does this by replacing humid, contami-
nated indoor air with dry, fresh, clean air from

Содержание Dri-X Airchanger

Страница 1: ...read before using the unit and save for future reference PURCHASE DATE ________________________________ SERIAL NO ___________________________________________ DEALER __________________________________...

Страница 2: ...Never remove or modify this three pronged plug Do not use an ungrounded two pronged adapter The grounding pin on the unit s plug is an essential safety feature that will help reduce the risk of shock...

Страница 3: ...ter one year the customer is responsible for all replacement parts labor and freight costs to and from the service center To receive warranty parts All replacement parts must be pre authorized through...

Страница 4: ...placed in any convenient drain The amount of moisture being pumped out is only a small percentage of the water being re moved from the room A much greater amount is being removed as invisible water v...

Страница 5: ...on a water damage job One might think it would be good to just open doors and windows and let the outside air in that is use an open drying system How ever this could compromise building security or...

Страница 6: ...tain good airflow with TurboDryers in the entire drying area High volume and high velocity airflow will both raise the rate of evaporation and help mix the air being drawn into the Dri X and expelled...

Страница 7: ...the risk of personal injury shock or fire Place Pump Hose in a Drain The 40 foot pump hose is normally wrapped around the main handle when not in use During operation place the end of the hose in any...

Страница 8: ...If it senses a freezing temperature it switches off the blower pulling air from the outdoors During the shut off period the other blower continues to run forcing room temperature air through the Core...

Страница 9: ...ft to gal lons per day or right to pints per day Example In this case the difference between indoor and out door conditions is 77 gpp less 30 gpp or 47 gpp 77 30 47 Looking up 47 gpp on the graph you...

Страница 10: ...X Airchanger Calculator Danger Removal or alteration of the grounding plug or use of an adapter that defeats the unit s electrical grounding can create risk of serious personal in jury or fire in the...

Страница 11: ...Pull it straight out of the Core and leave it bent to one side Replace it in the same spot after cleaning the Core When removing or replacing the probe be careful not to damage the corrugations To re...

Страница 12: ...nough time passed for materials to dry FS 1 Allow more time for drying 2 Poor air movement FS 2 Increase air movement with Dri Eaz TurboDryers 3 Excessive air infiltration FS 3 Reduce unwanted airflow...